Initial US evaluation of second-generation capsule colonoscopy for detecting colon polyps

被引:8
|
作者
Morgan, Douglas R. [1 ]
Malik, Pramod R. [2 ]
Romeo, David P. [3 ]
Rex, Douglas K. [4 ]
机构
[1] Vanderbilt Univ, Dept Med, Div Gastroenterol Hepatol & Nutr, Vanderbilt Inst Global Hlth, Nashville, TN 37232 USA
[2] Gastroenterol Associates Tidewater PC, Virginia Gastroenterol Inst, Suffolk, VA USA
[3] Dayton Gastroenterol Inc, Beavercreek, OH USA
[4] Indiana Univ Hosp, Dept Med, Div Gastroenterol Hepatol, 550 N Univ Blvd, Indianapolis, IN 46202 USA
来源
BMJ OPEN GASTROENTEROLOGY | 2016年 / 3卷 / 01期
关键词
D O I
10.1136/bmjgast-2016-000089
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Objectives: Capsule colonoscopy is an additional screening modality for colorectal cancer. Secondgeneration capsule colonoscopy (CC2) may have improved efficacy in the detection of colon adenomas as compared with prior devices. The purpose of this study was to evaluate the performance of CC2 in the detection of polyps in symptomatic and screening patients in the USA. Design: Prospective, multicentre study. Setting and participants: Two academic medical centres and two private practice facilities, evaluating patients with indications for colonoscopy. Methods: Patients underwent capsule colonoscopy procedure using magnesium citrate as a boost, followed by colonoscopy on the same day. The main outcome measurement was accuracy of CC2 for the detection of colorectal polyps >= 6 and >= 10 mm as compared with conventional colonoscopy. Results: 51 patients were enrolled, 50 of whom had CC2 and colonoscopy examinations and were included in the accuracy analysis. 30% and 14% of patients had polyps >= 6 and >= 10 mm, respectively. For lesions >= 10 mm identified on conventional colonoscopy, CC2 sensitivity was 100% (95% CI 56.1% to 100%) with a specificity of 93.0% (79.9% to 98.2%). For polyps >= 6 mm, the CC2 sensitivity was 93.3% (66.0% to 99.7%) and the specificity was 80.0% (62.5% to 90.9%). There was a 61% adequate cleansing rate with 64% of CC2 procedures being complete. Conclusions: In the initial US experience with CC2 there was adequate sensitivity for detecting patients with polyps >= 6 mm in size. Magnesium citrate was inadequate as a boost agent.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] SECOND-GENERATION PILLCAM® COLON CAPSULE COMPARED WITH COLONOSCOPY
    Spada, C.
    Hassan, C.
    Munos-Navaz, M. A.
    Neuhaus, H.
    Deviere, J. M.
    Fockens, P.
    Coron, E.
    Gay, G.
    Toth, E.
    Riccioni, M. E.
    Carretero, C.
    Charton, J. P.
    Van Gossum, A. M.
    Wientjes, C.
    Sacher-Huvelin, S.
    Delvaux, M.
    Nemeth, A.
    Cesaro, P.
    Prieto De Frias, C.
    Mayershofer, R.
    Amininejad, L.
    Dekker, E.
    Galmiche, J. P.
    Frederic, M.
    Johansson, G. Wurm
    Petruzziello, L.
    Costamagna, G.
    DIGESTIVE AND LIVER DISEASE, 2011, 43 : S115 - S115
  • [2] Second-generation colon capsule endoscopy compared with colonoscopy
    Spada, Cristiano
    Hassan, Cesare
    Munoz-Navas, Miguel
    Neuhaus, Horst
    Deviere, Jacques
    Fockens, Paul
    Coron, Emmanuel
    Gay, Gerard
    Toth, Ervin
    Riccioni, Maria Elena
    Carretero, Cristina
    Charton, Jean P.
    Van Gossum, Andre
    Wientjes, Carolien A.
    Sacher-Huvelin, Sylvie
    Delvaux, Michel
    Nemeth, Artur
    Petruzziello, Lucio
    Prieto de Frias, Cesar
    Mayershofer, Rupert
    Aminejab, Leila
    Dekker, Evelien
    Gahniche, Jean-Paul
    Frederic, Muriel
    Johansson, Gabriele Wurm
    Cesaro, Paola
    Costamagna, Guido
    GASTROINTESTINAL ENDOSCOPY, 2011, 74 (03) : 581 - 589
  • [3] Prospective Multicenter Performance Evaluation of the Second-Generation Colon Capsule Compared with Colonoscopy
    Eliakim, R.
    Yassin, K.
    Niv, Y.
    Metzger, Y.
    Lachter, J.
    Ga, E.
    Sapoznikov, B.
    Konikoff, F.
    Leichtmann, G.
    Fireman, Z.
    Kopelman, Y.
    Adler, S. N.
    ENDOSKOPIE HEUTE, 2010, 23 (02) : 144 - 149
  • [4] Prospective multicenter performance evaluation of the second-generation colon capsule compared with colonoscopy
    Eliakim, R.
    Yassin, K.
    Niv, Y.
    Metzger, Y.
    Lachter, J.
    Gal, E.
    Sapoznikov, B.
    Konikoff, F.
    Leichtmann, G.
    Fireman, Z.
    Kopelman, Y.
    Adler, S. N.
    ENDOSCOPY, 2009, 41 (12) : 1026 - 1031
  • [5] Detecting esophageal disease with second-generation capsule endoscopy: initial evaluation of the PillCam ESO 2
    Gralnek, I. M.
    Adler, S. N.
    Yassin, K.
    Koslowsky, B.
    Metzger, Y.
    Elialkim, R.
    ENDOSCOPY, 2008, 40 (04) : 275 - 279
  • [6] Role of Second-Generation Colon Capsule Endoscopy for Whole Gut Evaluation
    Spada, Cristiano
    Hassan, Cesare
    Campanale, Mariachiara
    Petruzziello, Lucio
    Costamagna, Guido
    GASTROINTESTINAL ENDOSCOPY, 2015, 81 (05) : AB476 - AB476
  • [7] Second-generation colon capsule endoscopy compared with colonoscopy (vol 74, pg 581, 2011)
    Amininejad, Leila
    GASTROINTESTINAL ENDOSCOPY, 2011, 74 (05) : 1174 - 1174
  • [8] Second-generation colon capsule endoscopy vs. colonoscopy in pediatric ulcerative colitis: a pilot study
    Oliva, Salvatore
    Di Nardo, Giovanni
    Hassan, Cesare
    Spada, Cristiano
    Aloi, Marina
    Ferrari, Federica
    Redler, Adriano
    Costamagna, Guido
    Cucchiara, Salvatore
    ENDOSCOPY, 2014, 46 (06) : 485 - 492
  • [9] Colon Capsule Endoscopy After Incomplete Colonoscopy: Initial US Experience
    Ali, Rabia
    Hass, David J.
    Schmelkin, Ira
    James-Stevenson, Toyia
    Di Palma, Jack A.
    Rajan, Elizabeth
    Henderson, Phillip K.
    Gross, Seth A.
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2015, 110 : S623 - S624
  • [10] ROLE OF SECOND-GENERATION COLON CAPSULE ENDOSCOPY (CCE-2) FOR WHOLE GUT EVALUATION
    Spada, C.
    Hassan, C.
    Campanale, M.
    Petruzziello, L.
    Costamagna, G.
    DIGESTIVE AND LIVER DISEASE, 2015, 47 : E196 - E197