ENZYME-IMMUNOASSAY - A NEW TECHNIQUE FOR ESTIMATING HEMOGLOBIN A1C

被引:0
|
作者
JOHN, WG
GRAY, MR
BATES, DL
BEACHAM, JL
机构
[1] ROYAL POSTGRAD MED SCH,DEPT CHEM PATHOL,LONDON W12 0NN,ENGLAND
[2] DAKO DIAGNOST LTD,ELY CB7 4ET,ENGLAND
关键词
GLYCOHEMOGLOBIN; DIABETES; REFERENCE INTERVAL;
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
We describe a method for estimating hemoglobin A1c (HbA1c) with a commercially available enzyme immunoassay system. The method is based on microtiter plate technology, utilizing an antibody raised to hemoglobin, the epitope being the Amadori product of glucose plus the first eight amino acids on the N-terminal end of the beta chain of hemoglobin. The enzyme immunoassay displays good within-batch (CV 2.3-2.4%) and between-batch (CV 2.6-5.0%) precision, and the results were not affected by different types of anticoagulant. The method was linear within the expected range of results and showed good correlation (r = 0.88-0.98) with established methods for estimating glycohemoglobin. Using this method, we obtained a reference interval of 2.8-4.9% (central 95%) for HbA1c in a nondiabetic population. The percentages of hemoglobin that were HbA1c in diabetics (6.86% +/- 2.51%) were significantly greater (P <0.001) than in nondiabetics (3.46% +/- 0.52%).
引用
收藏
页码:663 / 666
页数:4
相关论文
共 50 条
  • [31] Hemoglobin Raleigh results in factitiously low hemoglobin A1c when evaluated via immunoassay analyzer
    Jain, Nina
    Kesimer, Mehmet
    Hoyer, James D.
    Calikoglu, Ali S.
    JOURNAL OF DIABETES AND ITS COMPLICATIONS, 2011, 25 (01) : 14 - 18
  • [32] A NEW HOMOGENOUS ENZYME-IMMUNOASSAY USING RECOMBINANT ENZYME FRAGMENTS
    KHANNA, PL
    DWORSCHACK, RT
    MANNING, WB
    HARRIS, JD
    CLINICA CHIMICA ACTA, 1989, 185 (03) : 231 - 240
  • [33] What's new about hemoglobin A1C?
    Gillery, P
    ANNALES DE BIOLOGIE CLINIQUE, 1999, 57 (04) : 455 - 457
  • [34] A new automated enzymatic assay for hemoglobin A1c
    Taniguchi, Y
    Nishio, T
    Saito, K
    Yago, H
    Ushizawa, K
    CLINICAL CHEMISTRY, 2005, 51 : A246 - A246
  • [35] ENZYME-IMMUNOASSAY OF DELTA-1-PYRROLINE
    SAKAMOTO, S
    SAMEJIMA, K
    JOURNAL OF PHARMACOBIO-DYNAMICS, 1980, 3 (05): : S24 - S24
  • [36] RAPID ENZYME-IMMUNOASSAY OF SERUM CORTISOL USING A NEW TRANSFERABLE NEEDLE LID TECHNIQUE
    DHAR, TK
    VOSS, E
    MULLER, C
    KAGE, A
    SCHONESHOFER, M
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1985, 23 (09): : 624 - 624
  • [37] Standardization of hemoglobin A1c
    Johnson, R
    CLINICAL CHEMISTRY, 1998, 44 (05) : 1068 - 1068
  • [38] Significance of hemoglobin A1c
    Purucker, E
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2001, 126 (20) : 608 - 609
  • [39] HEMOGLOBIN A1C AND UREMIA
    LUND, L
    MOURITSANDERSEN, T
    SORENSEN, PJ
    CLINICAL NEPHROLOGY, 1988, 29 (03) : 161 - 162
  • [40] Glucose and Hemoglobin A1c
    Freeman, Vicki S.
    LABMEDICINE, 2014, 45 (01): : E21 - E24