THE GORE-TEX ANTERIOR CRUCIATE LIGAMENT PROSTHESIS - A LONG-TERM FOLLOW-UP

被引:78
|
作者
PAULOS, LE [1 ]
ROSENBERG, TD [1 ]
GREWE, SR [1 ]
TEARSE, DS [1 ]
BECK, CL [1 ]
机构
[1] ORTHOPED SPECIALTY HOSP,SALT LAKE CITY,UT
来源
AMERICAN JOURNAL OF SPORTS MEDICINE | 1992年 / 20卷 / 03期
关键词
D O I
10.1177/036354659202000302
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The GORE-TEX anterior cruciate ligament prosthesis has been implanted in 268 patients at our institution since April of 1984. Follow-up for this study was available on 70% of these patients (1 88). Eighty-one percent (152) of these had the ligament for chronic injuries, 14% (26) for acute, and 5% (10) for subacute injuries. The patient population had an average age of 27.6 years (SD = 8.4) and a Tegner activity score of 6.05 (SD = 1.53). Prior procedures had been performed on 56% (105) of the patients. Concomitant procedures were performed in 73% (137) and included iliotibial band tenodesis, partial meniscectomy, posterior oblique ligament advancement, or meniscal repair. Followup averaged 48 months (range, 24 to 68). Evaluation included a questionnaire, physical examination, radiographs, KT-1000 arthrometer testing, and an activity score. Results were graded as excellent, good, fair, and poor. Acceptable results (good and excellent) were obtained in 83 patients (44%). Fifty-eight patients (32%) were rated excellent and 25 (13%) were rated good. Unacceptable results (fair and poor) were obtained in 105 patients (56%). Twenty-five patients (13%) were rated fair and 80 (42%) were rated poor. Subjective improvement was indicated by 166 patients (88%). Activity levels postoperatively as rated by the Tegner Scale improved in 2 (1%), remained the same in 167 (89%), and decreased in 19 patients (10%). Effusions occurred in 63 patients (34%) and caused an unacceptable result in 22 (12%). Rupture occurred in 23 patients (12%). Loosening greater than 3 mm occurred in 64 patients (34%) and led to unacceptable results in 37 (20%). Infection occurred in 5 patients (2.7%). Excellent results had a statistically significantly higher age and lower activity score than the poor results (P = 0.045 and 0.012, respectively). The patients with previous intraarticular reconstructions had a 76% unacceptable rating (16 of 21).
引用
收藏
页码:246 / 252
页数:7
相关论文
共 50 条
  • [41] Combined treatment with medial unicompartmental knee arthroplasty and anterior cruciate ligament reconstruction is effective on long-term follow-up
    Ayham Jaber
    Chang min Kim
    Alexander Barié
    Marcus Streit
    Holger Schmitt
    Michael Clarius
    Christian Merle
    Yannic Bangert
    Knee Surgery, Sports Traumatology, Arthroscopy, 2023, 31 : 1382 - 1387
  • [42] LONG-TERM FOLLOW-UP OF ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTIONS USING FREEZE-DRIED FASCIA LATA ALLOGRAFTS
    PRITCHARD, JC
    DREZ, D
    MOSS, M
    HECK, S
    AMERICAN JOURNAL OF SPORTS MEDICINE, 1995, 23 (05): : 593 - 596
  • [43] Outcome and knee-related quality of life after anterior cruciate ligament reconstruction: a long-term follow-up
    Eva Möller
    Lars Weidenhielm
    Suzanne Werner
    Knee Surgery, Sports Traumatology, Arthroscopy, 2009, 17 : 786 - 794
  • [44] THE LONG-TERM COURSE AFTER TREATMENT OF ACUTE ANTERIOR CRUCIATE LIGAMENT RUPTURES - A 9 TO 16 YEAR FOLLOW-UP
    SOMMERLATH, K
    LYSHOLM, J
    GILLQUIST, J
    AMERICAN JOURNAL OF SPORTS MEDICINE, 1991, 19 (02): : 156 - 162
  • [45] ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION USING QUADRICEPS PATELLAR TENDON GRAFT .1. LONG-TERM FOLLOW-UP
    HOWE, JG
    JOHNSON, RJ
    KAPLAN, MJ
    FLEMING, B
    JARVINEN, M
    AMERICAN JOURNAL OF SPORTS MEDICINE, 1991, 19 (05): : 447 - 457
  • [46] Medium- to Long-Term Follow-up after Anterior Cruciate Ligament Rupture and Repair in Healing Response Technique
    Jorjani, J.
    Altmann, D.
    Auen, R.
    Koopmann, C.
    Lyutenski, B.
    Wirtz, D. C.
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2013, 151 (06): : 570 - 579
  • [47] LONG-TERM CLINICAL-TRIAL OF THE GORE-TEX PERITONEAL CATHETER (GTC)
    BAY, WH
    POWELL, SL
    KIDNEY INTERNATIONAL, 1984, 25 (01) : 255 - 255
  • [48] MEDIUM-TERM FOLLOW-UP OF 40 AUTOGENOUS VEIN AND 40 POLYTETRAFLUOROETHYLENE (GORE-TEX) GRAFTS FOR VASCULAR ACCESS
    JENKINS, AM
    BUIST, TAS
    GLOVER, SD
    SURGERY, 1980, 88 (05) : 667 - 672
  • [49] Midterm follow-up of the status of Gore-Tex graft after extracardiac conduit Fontan procedure
    Lee, Cheul
    Lee, Chang-Ha
    Hwang, Seong Wook
    Lim, Hong Gook
    Kim, Soo-Jin
    Lee, Jae Young
    Shim, Woo-Sup
    Kim, Woong-Han
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2007, 31 (06) : 1008 - 1012
  • [50] SURGICAL OR NON-SURGICAL TREATMENT OF ACUTE RUPTURE OF THE ANTERIOR CRUCIATE LIGAMENT - A RANDOMIZED STUDY WITH LONG-TERM FOLLOW-UP
    ANDERSSON, C
    ODENSTEN, M
    GOOD, L
    GILLQUIST, J
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1989, 71A (07): : 965 - 974