AN EXPERIMENTAL-STUDY OF STEADY-STATE BEHAVIOR OF A 2-PHASE NATURAL CIRCULATION LOOP

被引:5
|
作者
CHEN, KS
CHEN, YY
SHIAO, SW
WANG, PC
机构
[1] Department of Mechanical Engineering, National Sun Yat-Sen University, Kaohsiung
[2] Energy Conservation Section, Research and Development Department, China Steel Corp.
关键词
NATURAL CIRCULATION LOOP; THERMOSIPHON LOOP; 2-PHASE FLOW;
D O I
10.1016/0196-8904(91)90090-6
中图分类号
O414.1 [热力学];
学科分类号
摘要
An experimental study on the steady-state behavior for a square, two-phase, natural circulation loop with water-steam as the working fluid is carried out in this study. Measurements of temperature and pressure distributions of the fluid around the loop were made under various heating and liquid-charge level conditions. Results show that fluid temperature and pressure at each location in the loop increase with increasing input power at a fixed percentage charge level. Higher fluid temperatures are observed at low percentage charge levels, and the overall heat transfer coefficient of the loop decreases with increasing percentage charge level at a fixed input power.
引用
下载
收藏
页码:553 / 559
页数:7
相关论文
共 50 条
  • [21] Steady-State Behavior of Natural Circulation Loops Operating With Supercritical Fluids for Open and Closed Loop Boundary Conditions
    Sharma, Manish
    Pilkhwal, Darwan S.
    Vijayan, Pallipattu K.
    Saha, Dilip
    Sinha, Ratan K.
    HEAT TRANSFER ENGINEERING, 2012, 33 (09) : 809 - 820
  • [22] ON THE STEADY-STATE PERFORMANCE OF NATURAL CIRCULATION LOOPS
    VIJAYAN, PK
    MEHTA, SK
    DATE, AW
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1991, 34 (09) : 2219 - 2230
  • [23] Effects of various modeling assumptions on steady-state and transient performances of single-phase natural circulation loop
    Sahu, Mayaram
    Sarkar, Jahar
    Chandra, Laltu
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2021, 124
  • [24] Experimental study on distortion of scale-down methodology for natural circulation steady-state phenomena
    Cheng, Cheng
    Lu, Donghua
    Su, Qianhua
    Huang, Yaji
    Wu, Xiaohang
    ANNALS OF NUCLEAR ENERGY, 2023, 182
  • [25] A study on the steady-state flow behavior of the flashing-driven open natural circulation system
    Hou Xiaofan
    Qiu Jinrong
    Sun Zhongning
    Yao Shiwei
    He Chuan
    Yang Xu
    Wang Shiming
    Yang Yongqiang
    APPLIED THERMAL ENGINEERING, 2021, 182
  • [26] Steady-State Performance of a Rectangular Natural Circulation Loop With Differentially Heated Parallel Channels
    Chakraborty, Shubhankar
    Das, Prasanta Kr
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2016, 8 (01)
  • [27] EXPERIMENTAL-STUDY OF STEADY-STATE RESPONSE OF OIL-FILM DAMPERS
    SHARMA, RK
    BOTMAN, M
    MECHANICAL ENGINEERING, 1978, 100 (01) : 110 - 110
  • [29] EXPERIMENTAL-STUDY OF STEADY-STATE LOCALIZATION IN COUPLED BEAMS WITH ACTIVE NONLINEARITIES
    KING, ME
    AUBRECHT, J
    VAKAKIS, AF
    JOURNAL OF NONLINEAR SCIENCE, 1995, 5 (06) : 485 - 502
  • [30] EXPERIMENTAL-STUDY OF THE STEADY-STATE RESPONSE OF OIL-FILM DAMPERS
    SHARMA, RK
    BOTMAN, M
    JOURNAL OF MECHANICAL DESIGN-TRANSACTIONS OF THE ASME, 1978, 100 (02): : 216 - 221