TENSION BAND INTERNAL-FIXATION WITH RESORBABLE THREADS FOR COMMINUTED FRACTURES OF THE PROXIMAL HUMERUS

被引:0
|
作者
OCHSNER, PE
ILCHMANN, T
机构
来源
UNFALLCHIRURG | 1991年 / 94卷 / 10期
关键词
D O I
暂无
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
We reviewed 25 cases of comminuted fractures of the proximal humerus that were operatively treated from December 1984 to December 1988. Ten patients were treated by a Magerl operation modified by Marti using a metallic wire as a tension band. Twelve patients were operated on using a resorbable PDS (Polydioxanon) thread in the same manner. In this paper the PDS thread technique is described. The two groups are clinically and radiologically comparable. Using a PDS thread as a tension band has evident advantages: the relatively simple technique and the absence of implant removal.
引用
收藏
页码:508 / 510
页数:3
相关论文
共 50 条