摘要
In the present article the failure behaviour of a steel, beam type element supported against fire by protection boards, is studied. Three dimensional, coupled temperature - displacement, non-linear finite element analysis models have been developed to simulate the unprotected and protected structure. A simple modelling approach is proposed for the investigation of the influence of the gradual failure of fire protection at elevated temperatures, on the structural performance of the system, under thermal and mechanical loads. Yielding of steel is depicted and force displacement diagrams are used to evaluate the ultimate behaviour of the unprotected and protected models. It is shown that for the protected structure, yielding is less severe and the time period up to maximum strength is significantly longer. Eventually, is depicted how failure of the fire protection leads to a gradual reduction of the response, in fire conditions.
引用
收藏
页码:124 / 139
页数:16
相关论文
共 50 条
  • [21] Behaviour of steel joints under fire loading
    da Silva, LS
    Santiago, A
    Real, PV
    Moore, D
    STEEL AND COMPOSITE STRUCTURES, 2005, 5 (06): : 485 - 513
  • [22] Fire resistivity of steel and aluminium constructions protected by a bloated coating
    Orlowsky, Y
    Orlowska, K
    Shnal, T
    LIGHT-WEIGHT STEEL AND ALUMINIUM STRUCTURES, 1999, : 561 - 566
  • [23] EXPERIMENTAL STUDIES OF UNPROTECTED AND PROTECTED STEEL STRUCTURES UNDER FIRE
    Saulnier, Veronique
    Durif, Sebastien
    Bouchair, Abdelhamid
    Audebert, Philippe
    Lahmar, Mohamed
    APPLICATIONS OF STRUCTURAL FIRE ENGINEERING, 2017,
  • [24] Numerical and Design Analysis of Protected Steel Columns in Standard Fire
    Aghabozorgi, Pegah
    Laim, Luis
    Santiago, Aldina
    FIRE TECHNOLOGY, 2025,
  • [25] FIRE ENDURANCE OF CONCRETE-PROTECTED STEEL COLUMNS.
    Lie, T.T.
    Harmathy, T.Z.
    Journal of The American Concrete Institute, 1974, 71 (01): : 29 - 32
  • [26] Temperature evaluation in steel fire protected elements with intumescent coating
    Mesquita, L. M. R.
    Piloto, P. A. G.
    Vaz, M. A. P.
    Safety and Security Engineering II, 2007, 94 : 233 - 242
  • [27] Finite Element Modelling of the Structural Behaviour of a Novel Cellular Beam Non-composite Steel Structure in Fire
    M. Kloos
    R. S. Walls
    International Journal of Steel Structures, 2019, 19 : 1367 - 1380
  • [28] Finite Element Modelling of the Structural Behaviour of a Novel Cellular Beam Non-composite Steel Structure in Fire
    Kloos, M.
    Walls, R. S.
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2019, 19 (05) : 1367 - 1380
  • [29] The behaviour of asymmetric slim floor steel beams in fire
    Bailey, CG
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1999, 50 (03) : 235 - 257
  • [30] The collapse behaviour of braced steel frames exposed to fire
    Sun, Ruirui
    Huang, Zhaohui
    Burgess, Ian W.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2012, 72 : 130 - 142