Failure behaviour of a fire protected steel element

被引:0
|
作者
Motsa, Siphesihle [1 ]
Drosopoulos, Georgios [1 ]
机构
[1] Univ KwaZulu Natal, Discipline Civil Engn, Struct Engn & Computat Mech Grp, Durban, South Africa
来源
关键词
Steel structures; Fire; Protection; Coupled analysis; Finite element analysis;
D O I
10.3221/IGF-ESIS.46.13
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In the present article the failure behaviour of a steel, beam type element supported against fire by protection boards, is studied. Three dimensional, coupled temperature - displacement, non-linear finite element analysis models have been developed to simulate the unprotected and protected structure. A simple modelling approach is proposed for the investigation of the influence of the gradual failure of fire protection at elevated temperatures, on the structural performance of the system, under thermal and mechanical loads. Yielding of steel is depicted and force displacement diagrams are used to evaluate the ultimate behaviour of the unprotected and protected models. It is shown that for the protected structure, yielding is less severe and the time period up to maximum strength is significantly longer. Eventually, is depicted how failure of the fire protection leads to a gradual reduction of the response, in fire conditions.
引用
收藏
页码:124 / 139
页数:16
相关论文
共 50 条
  • [1] Fire behaviour of fire-protected concrete-filled steel tubular columns
    Lou, Guo-Biao
    Tan, Rui-Xin
    Qi, Hong-Hui
    Rao, Wen-Ting
    Huang, Dai-Fa
    Zhao, Xin
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2025, 226
  • [2] Protected Steel and Composite Connections Simulation of the Mechanical Behaviour of Steel and Composite Connections Protected by Intumescent Coating in Fire
    Schaumann, Peter
    Kirsch, Thomas
    JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2015, 6 (01) : 41 - 48
  • [3] Non-linear finite element analysis of a fire protected steel connection
    Singh, I
    Drosopoulos, G. A.
    Stavroulakis, G. E.
    ADVANCES IN ENGINEERING MATERIALS, STRUCTURES AND SYSTEMS: INNOVATIONS, MECHANICS AND APPLICATIONS, 2019, : 1915 - 1920
  • [4] FIRE RESISTANCE OF PROTECTED STEEL COLUMNS
    LIE, TT
    STANZAK, WW
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION INC, 1973, 10 (03): : 82 - 94
  • [5] FIRE RESISTANCE OF PROTECTED STEEL COLUMNS
    STETINA, HJ
    LIE, TT
    STANZAK, WW
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION INC, 1973, 10 (04): : 134 - 136
  • [6] Flammability and burning behaviour of fire protected timber
    Hansen-Bruhn, Iben
    Hull, T. Richard
    FIRE SAFETY JOURNAL, 2023, 140
  • [7] Resistance of partially protected steel beams in fire
    Hautala, Janne
    Kangashaka, Iida
    Malaska, Mikko
    Pajunen, Sami
    ce/papers, 2021, 4 (2-4) : 1849 - 1855
  • [8] Experimental study on the fire resistance of steel columns protected with fire boards
    In-Kyu Kwon
    Young-Bong Kwon
    International Journal of Steel Structures, 2012, 12 : 25 - 35
  • [9] Experimental Study on the Fire Resistance of Steel Columns Protected with Fire Boards
    Kwon, In-Kyu
    Kwon, Young-Bong
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2012, 12 (01) : 25 - 35
  • [10] FAILURE OF STEEL COLUMNS IN FIRE
    BURGESS, IW
    OLAWALE, AO
    PLANK, RJ
    FIRE SAFETY JOURNAL, 1992, 18 (02) : 183 - 201