PULSE OXIMETRY DURING FIBEROPTIC BRONCHOSCOPY IN LOCAL-ANESTHESIA - FREQUENCY OF HYPOXEMIA AND EFFECT OF OXYGEN SUPPLEMENTATION

被引:0
|
作者
MILMAN, N
FAURSCHOU, P
GRODE, G
JORGENSEN, A
机构
关键词
FIBEROPTIC BRONCHOSCOPY; HYPOXEMIA; OXYGEN CATHETER; OXYGEN TREATMENT; PULSE OXIMETRY;
D O I
暂无
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
The indication for oxygen supplementation during diagnostic fibreoptic bronchoscopy (FOB) in local anaesthesia was evaluated by means of pulse oximetry in 160 patients (108 men, 52 women), median age 62 years. The patients were allocated at random into four groups of each 40 persons, which were comparable concerning pulmonary function and the dose of benzodiazepine used for premedication. The oxygen saturation of the haemoglobin (SpO(2)) in the tip of the index finger and the pulse rate were continuously recorded. Group 1 was examined without O-2 supplement. Group 2a received O-2 2 litres/min through a pharyngeal catheter. Group 3 received O-2 3 litres/min through a pharyngeal catheter. SpO(2) mean values during FOB were 92 +/- (SD) 3% in group 1 and 96 +/- 2% in groups 2a, 2b and 3 (p<0.001). SpO(2) <85%, occurred with a frequency of 35% in group 1, 2.5% in group 2a, 0% in group 2b, and 2.5% in group 3. Tachycardia and bradycardia during FOB occurred with a frequency of 20% in group 1, 25% in group 2a, 18% in group 2b, and 10% in group 3. Pulse oximetry increases the safety of FOB, and is recommended for routine use. During FOB, oxygen supplement 2-3 litres/min should be administered to all patients, preferably through a pharyngeal catheter, as a preventive measure against hypoxaemia.
引用
收藏
页码:342 / 347
页数:6
相关论文
共 40 条
  • [21] COMPARISON OF DIAZEPAM AND FLUNITRAZEPAM FOR SEDATION DURING LOCAL-ANESTHESIA FOR BRONCHOSCOPY
    KORTTILA, K
    SAARNIVAARA, L
    TARKKANEN, J
    HIMBERG, JJ
    HYTONEN, M
    BRITISH JOURNAL OF ANAESTHESIA, 1978, 50 (03) : 281 - 287
  • [22] THE PREVALENCE OF HYPOXEMIA DETECTED BY PULSE OXIMETRY DURING RECOVERY FROM ANESTHESIA
    MORRIS, RW
    BUSCHMAN, A
    WARREN, DL
    PHILIP, JH
    RAEMER, DB
    JOURNAL OF CLINICAL MONITORING, 1988, 4 (01): : 16 - 20
  • [23] Esophageal pulse oximetry is more accurate and detects hypoxemia earlier than conventional pulse oximetry during general anesthesia
    Guo Chen
    Zhaoqiong Zhu
    Jin Liu
    Wei Wei
    Frontiers of Medicine, 2012, 6 (4) : 406 - 410
  • [24] Nitrous oxide in oxygen versus oxygen for painful procedure in children during flexible fiberoptic bronchoscopy with local anesthesia.
    Garcia, J
    Roure, P
    Hayem, C
    Dupont, D
    REVUE DES MALADIES RESPIRATOIRES, 1998, 15 (02) : 179 - 183
  • [25] ARTERIAL OXYGEN-SATURATION DURING ND-YAG LASER PHOTORESECTION OF ENDOBRONCHIAL TUMORS UNDER LOCAL-ANESTHESIA - USE OF INTERMITTENT SUPPLEMENTAL OXYGEN WITH PULSE OXIMETRY GUIDANCE
    SCHIFFMAN, PL
    WILHELM, J
    PARISI, RA
    CHEST, 1988, 94 (06) : 1300 - 1301
  • [26] ANESTHESIA-RELATED HYPOXEMIA - THE EFFECT OF PULSE OXIMETRY MONITORING ON PERIOPERATIVE EVENTS AND POSTOPERATIVE COMPLICATIONS
    MOLLER, JT
    DANISH MEDICAL BULLETIN, 1994, 41 (05) : 489 - 500
  • [27] Blood pressure control during eye surgery under local anesthesia using pulse oximetry
    Mamiya, K
    Manabe, M
    Aono, J
    Ueno, H
    OPHTHALMOLOGICA, 1998, 212 (04) : 236 - 238
  • [28] Effect of maternal position on fetal oxygen saturation measured by pulse oximetry during labor
    de Morais, EN
    Spara, P
    El Beitune, P
    Madi, JM
    PERINATOLOGY 2001, VOLS 1 AND 2, 2001, : 283 - 286
  • [29] The effect of maternal oxygen administration during labor on fetal pulse oximetry: A pilot study
    Haydon, M
    Gorenberg, D
    Ghamsary, M
    Rumney, P
    Patillo, C
    Nageotte, M
    Garite, T
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2005, 193 (06) : S33 - S33
  • [30] EFFECT OF GENERAL AND LOCAL-ANESTHESIA ON BLOOD-LOSS DURING AND AFTER THERAPEUTIC-ABORTION
    MOLLER, BR
    HANSEN, JT
    MOMMSEN, S
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 1978, 57 (02) : 133 - 135