Two-Color Diffused Back-Illumination Imaging as a Diagnostic for Time-Resolved Soot Measurements in Reacting Sprays

被引:66
|
作者
Manin, Julien [1 ]
Pickett, Lyle M.
Skeen, Scott A. [1 ]
机构
[1] Sandia Natl Labs, Livermore, CA 94550 USA
基金
美国能源部;
关键词
D O I
10.4271/2013-01-2548
中图分类号
U [交通运输];
学科分类号
08 ; 0823 ;
摘要
Despite ongoing research efforts directed at reducing engine-out emissions, diesel engines are known to be one of the largest sources of atmospheric particulate matter (i.e., soot). Quantitative measurements are of primary importance to address soot production during the combustion process in the cylinder of diesel engines. This study presents the capabilities of an extinction-based diagnostic developed to quantitatively measure the soot volume fraction in n-dodecane sprays injected in a high-pressure, high-temperature vessel. Coupled with high-speed imaging, the technique yields time-resolved measurements of the soot field by relying on a diffused back-illumination scheme to improve extinction quantification in the midst of intense beam steering. The experiments performed in this work used two wavelengths, which, when combined with the Rayleigh-Debye-Gans theory, provide information about the optical and physical properties of soot. For validation of the extinction imaging technique and comparison with prior work, the path-averaged soot volume fraction has been simultaneously measured using laser extinction. We found the sensitivity of this diagnostic to soot volume fraction to be below 1 ppm despite beam-steering influences in the time-resolved data, and we were able to quantify higher soot concentrations in engine-relevant spray flames than previous studies by our group that used laser-induced incandescence (LII) in conjunction with path-averaged laser extinction. This work demonstrated a preference for shorter visible wavelengths, as soot-generated extinction is higher while broadband flame emission is lower at these wavelengths. Consequently, shorter visible wavelengths resulted in a greater signal-to-noise ratio. Analysis of two-color extinction indicated that the refractive index and morphological properties of soot change during the formation and oxidation processes.
引用
收藏
页码:1908 / 1921
页数:14
相关论文
共 43 条
  • [21] Significant Enhancement of Third-and Fifth-Harmonic Generation in Air via Two-Color, Time-Resolved Methods
    Weerawarne, Darshana L.
    Grynko, Rostislav I.
    Meyer, Henry J.
    Shim, Bonggu
    2015 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2015,
  • [22] Time-Resolved Tracking of Separately Internalized Neuropeptide Y2 Receptors by Two-Color Pulse-Chase
    Lotze, Jonathan
    Wolf, Philipp
    Reinhardt, Ulrike
    Seitz, Oliver
    Moerl, Karin
    Beck-Sickinger, Annette G.
    ACS CHEMICAL BIOLOGY, 2018, 13 (03) : 618 - 627
  • [23] Time-Resolved Two-Color X-ray Pump / X-ray Probe Photoelectron Spectroscopy at LCLS
    Al Haddad, Andre
    Picon, Antonio
    Bucher, Maximilian
    Doumy, Gilles
    Coffee, Ryan
    Holmes, Michael
    Krzywinski, Jacek
    Lutman, Alberto
    Marinelli, Agostino
    Moeller, Stefan
    Osipov, Timur
    Pratt, Stephen
    Ratner, Dan
    Ray, Dipanwita
    Walter, Peter
    Young, Linda
    Southworth, Stephen
    Bostedt, Christoph
    2017 CONFERENCE ON LASERS AND ELECTRO-OPTICS EUROPE & EUROPEAN QUANTUM ELECTRONICS CONFERENCE (CLEO/EUROPE-EQEC), 2017,
  • [24] Photo-doped carrier dynamics by two-color pump-probe time-resolved Raman scattering measurement in Ge
    Saito, S
    Suemoto, T
    JOURNAL OF LUMINESCENCE, 2000, 87-9 : 920 - 922
  • [25] Two-color pump-probe laser spectroscopy instrument with picosecond time-resolved electronic delay and extended scan range
    Yu, AC
    Ye, X
    Ionascu, D
    Cao, WX
    Champion, PM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (11): : 1 - 8
  • [26] Microscopic theory of electron dynamics and time-resolved two-color two-photon photoemission at semiconductor surfaces -: art. no. 245309
    Zeiser, A
    Bücking, N
    Förstner, J
    Knorr, A
    PHYSICAL REVIEW B, 2005, 71 (24)
  • [27] Application of stepwise two-color excitation time-resolved thermal lensing technique to the study on excited 2-methylbenzophenone enols
    Suzuki, T
    Ichimura, T
    ANALYTICAL SCIENCES, 2001, 17 : S23 - S25
  • [28] Time-lapse two-color 3D imaging of live cells with doubled resolution using structured illumination
    Fiolka, Reto
    Shao, Lin
    Rego, E. Hesper
    Davidson, Michael W.
    Gustafsson, Mats G. L.
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2012, 109 (14) : 5311 - 5315
  • [29] Synchronized Two-Color Time-Resolved Dual-Comb Spectroscopyfor Quantitative Detection of HOx Radicals Formed from Criegee Intermediates
    Luo, Pei-Ling
    Chen, I-Yun
    ANALYTICAL CHEMISTRY, 2022, 94 (15) : 5752 - 5759
  • [30] Two-laser two-color time-resolved EPR study on higher-excited-state triplet-singlet intersystem crossing of porphyrins and phthalocyanines
    Kamata, Y
    Akiyama, K
    Tero-Kubota, S
    Tabata, M
    APPLIED MAGNETIC RESONANCE, 2003, 23 (3-4) : 409 - 420