Self-Aligning Finger Exoskeleton for the Mobilization of the Metacarpophalangeal Joint

被引:0
|
作者
Peperoni, Emanuele [1 ,2 ]
Capitani, Stefano Laszlo [1 ,2 ]
Fiumalbi, Tommaso [1 ,2 ]
Capotorti, Eugenio [1 ,3 ]
Baldoni, Andrea [1 ,2 ]
Dell'Agnello, Filippo [1 ,2 ]
Creatini, Ilaria [4 ]
Taglione, Elisa [4 ]
Vitiello, Nicola [1 ,2 ,5 ]
Trigili, Emilio [1 ,2 ]
Crea, Simona [1 ,2 ,5 ]
机构
[1] BioRobot Inst, Scuola Super St Anna, I-56025 Pisa, Italy
[2] Scuola Super Sant Anna, Dept Excellence Robot & AI, I-56127 Pisa, Italy
[3] Johnson &Johnson Med Spa, I-00071 Rome, Italy
[4] Natl Inst Insurance Accid Work INAIL, Motor Rehabil Ctr, I-56048 Pisa, Italy
[5] IRCCS Fdn Don Gnocchi, I-50143 Florence, Italy
关键词
Rehabilitation robotics; kinematic com-patibility; human-robot interfaces; hand; exoskeleton;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In the context of hand and finger rehabilitation, kinematic compatibility is key for the acceptability and clinical exploitation of robotic devices. Different kinematic chain solutions have been proposed in the state of the art, with different trade-offs between characteristics of kinematic compatibility, adaptability to different anthropometries, and the ability to compute relevant clinical information. This study presents the design of a novel kinematic chain for the mobilization of the metacarpophalangeal (MCP) joint of the long fingers and a mathematical model for the real-time computation of the joint angle and transferred torque. The proposed mechanism can self-align with the human joint without hindering force transfer or inducing parasitic torque. The chain has been designed for integration into an exoskeletal device aimed at rehabilitating traumatic-hand patients. The exoskeleton actuation unit has a series-elastic architecture for compliant human-robot interaction and has been assembled and preliminarily tested in experiments with eight human subjects. Performance has been investigated in terms of (i) accuracy of the MCP joint angle estimation through comparison with a video-based motion tracking system, (ii) residual MCP torque when the exoskeleton is controlled to provide null output impedance and (iii) torque-tracking performance. Results showed a root-mean-square error (RMSE) below 5 degrees in the estimated MCP angle. The estimated residual MCP torque resulted below 7 mNm. Torque tracking performance shows an RMSE lower than 8 mNm in following sinusoidal reference profiles. The results encourage further investigations of the device in a clinical scenario.
引用
收藏
页码:884 / 894
页数:11
相关论文
共 50 条
  • [21] Self-Aligning Ruthenium Interconnects
    Schlag, Leslie
    Grau, Richard
    Hossain, Mobassar
    Nahrstedt, Helene
    Isaac, Nishchay Angel
    Reiprich, Johannes
    Pezoldt, Jorg
    Jacobs, Heiko Otto
    2020 IEEE INTERNATIONAL INTERCONNECT TECHNOLOGY CONFERENCE (IITC), 2020, : 82 - 84
  • [22] SELF-ALIGNING ROTATIONAL LATCHING MECHANISMS
    Fernandez, Gabriel I.
    Gessow, Samuel
    Quan, Justin
    Hong, Dennis
    PROCEEDINGS OF ASME 2022 INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, IDETC-CIE2022, VOL 7, 2022,
  • [23] The magnetic self-aligning hermaphroditic connector
    Nagy, Zoltan
    Abbott, Jake J.
    Nelson, Bradley J.
    2007 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS, VOLS 1-3, 2007, : 677 - 682
  • [24] SELF-ALIGNING SUPPORT OF ROTARY KILNS
    JENSEN, FE
    ZEMENT-KALK-GIPS, 1977, 30 (12): : 628 - 629
  • [25] SELF-ALIGNING OPTICAL MEASUREMENT SYSTEMS
    DECKER, AJ
    APPLIED OPTICS, 1992, 31 (22): : 4339 - 4340
  • [26] SELF-ALIGNING PLATENS FOR WEISSENBERG RHEOGONIOMETER
    HARRIS, J
    WILKINSO.WL
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1968, 1 (10): : 1030 - &
  • [27] Self-aligning coaxial PCB connectors
    Anon
    MICROWAVE JOURNAL, 1999, 42 (04) : 158 - 159
  • [28] Self-aligning gas/liquid micropump
    Schabmueller, CGJ
    Koch, M
    Mokhtari, ME
    Evans, AGR
    Brunnschweiler, A
    Sehr, H
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2002, 12 (04) : 420 - 424
  • [29] Self-aligning universal beam coupler
    Miller, David A. B.
    OPTICS EXPRESS, 2013, 21 (05): : 6360 - 6370
  • [30] SELF-ALIGNING OPTICAL BEAM WAVEGUIDES
    CHRISTIAN, JR
    GOUBAU, G
    MINK, JW
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1967, QE 3 (11) : 498 - +