AIR EXCHANGE RATE IN AIR QUALITY ASSURANCE - A CASE STUDY

被引:2
|
作者
Cirstoloveana, I. L. [1 ]
Hornet, M. [1 ]
Ancas, Ana Diana [2 ]
Profire, M. [2 ]
机构
[1] Transilvania Univ Brasov, Fac Bldg Engn, Brasov, Romania
[2] Tech Univ Gh Asachi Iasi, Fac Bldg Engn & Bldg Serv, Iasi, Romania
关键词
ventilation rate; thermal load; indoor temperature; measurements;
D O I
10.2478/jaes-2018-0002
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The goals of this paper are to estimate some parameters - indoor temperature and ventilation rate - necessary to determine the heat load demand for ventilation in the amphitheatre named 'A TALPOSI'-Faculty of Buildings Engineering-with a number of at the most 120 occupants. The study presented in this paper is made when in the amphitheatre it is necessary to assure a comfortable temperature by a permanent functioning of the heating system. The number of air exchanges necessary in the amphitheatre in the natural ventilation process, more exactly, to assure a minimum air exchanges, is imposed by the requirements for the assurance of physiologic comfort in the amphitheatre for the time interval when it is occupied by students. The inner air debit should cover the harmful emissions in the amphitheatre. By the help of these calculated (measured) parameters we have calculated the heat load for ventilation. In the end, with the data obtained from calculations and measurements we find ourselves in the situation of establishing the size of the heat exchanger corresponding to the room, to heat the fresh air taken from outside and send it inside the amphitheatre. The measurements are made with the TESTO apparatus of the faculty. The minimum requirements to assure the thermal comfort are: to achieve a minimum internal temperature theta i (t) higher than (or equal to) the normal indoor temperature associated to this space and to assure the air quality, the air exchange rate. The authors want to highlight by this study the necessity and importance of the control on the number of air exchanges in rooms with a high number of occupants and overall, the control of the fresh air debits. The fact that the focus is more and more on heat loss cuts in rooms by tightening closing elements gives birth to the necessity of control of the ventilation system with effects on the consumption of mechanical energy.
引用
收藏
页码:13 / 18
页数:6
相关论文
共 50 条
  • [1] Study on the impact of fresh air rate on indoor air quality
    Liu, Guodan
    Ye, Bichao
    Hu, Songtao
    Zhang, Changxing
    Zhang, Li
    Zhu, Chun
    PROCEEDINGS OF THE 3RD ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING VOLS I AND II, 2006, : 635 - +
  • [2] AIR CLEANING EQUIPMENT QUALITY ASSURANCE
    不详
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1977, 11 (01) : 24 - 25
  • [3] Trombay Air Quality A case study
    Deobhanj, Sanghamitra
    Chandra, G. Sharath
    Srinivasan, R.
    Lahkar, Jiumoni
    Shrivastava, Neeta
    Nair, Ashwathy
    Kumar, V. Anoop
    Mullasseri, Sileesh
    Gowdhaman, P.
    Balaji, S.
    Ramanan, S. Suresh
    CURRENT SCIENCE, 2018, 114 (07): : 1392 - 1392
  • [4] INDOOR CLIMATE AND AIR-QUALITY IN NEW OFFICES - EFFECTS OF A REDUCED AIR-EXCHANGE RATE
    BERARDI, BM
    LEONI, E
    MARCHESINI, B
    CASCELLA, D
    RAFFI, GB
    INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1991, 63 (04) : 233 - 239
  • [5] QUALITY ASSURANCE IN AMBIENT AIR MONITORING.
    Barker, D.R.
    Arbes, R.J.
    Carroll, G.
    Colaw, K.
    Sirois, E.H.
    Oti, L.
    Clean Air (Melbourne), 1987, 21 (01): : 34 - 38
  • [6] CONCEPTION OF QUALITY ASSURANCE FOR AMBIENT AIR MEASUREMENTS
    BUCK, M
    STAUB REINHALTUNG DER LUFT, 1989, 49 (10): : 337 - 342
  • [7] Air pollution model quality assurance: a review
    Canepa, E
    DEVELOPMENT AND APPLICATION OF COMPUTER TECHNIQUES TO ENVIRONMENTAL STUDIES, 2002, 9 : 61 - 70
  • [8] Critique of the Turkish Air Quality Assurance Regulation
    Okutan, H
    Cortoglu, S
    Ekinci, E
    AIR QUALITY MANAGMENT: AT URBAN, REGIONAL AND GLOBAL SCALES, 1997, : 570 - 572
  • [9] Fresh air rate in air conditioning buildings and indoor air quality
    Pei Qing-qing
    Liu Wei
    Zhou Zhi-ming
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2007, 14 : 95 - 98
  • [10] Ambient air quality at Visakhapatnam - A case study
    Mudri, S.S.
    Rao, D.V.
    Rama Rao, K.G.
    Indian Journal of Environmental Health, 1986, 28 (04) : 284 - 295