MONOCLONAL-ANTIBODIES FOR IMMUNOASSAY OF AVERMECTINS

被引:31
|
作者
SCHMIDT, DJ
CLARKSON, CE
SWANSON, TA
EGGER, ML
CARLSON, RE
VANEMON, JM
KARU, AE
机构
[1] UNIV CALIF BERKELEY,COLL NAT RESOURCES,DEPT PLANT PATHOL,HYBRIDOMA FACIL,BERKELEY,CA 94720
[2] ECOCHEM RES INC,CHASKA,MN 55318
[3] ENVIRONM MONITORING SYST LAB,LAS VEGAS,NV
关键词
D O I
10.1021/jf00098a028
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
We have developed a panel of mouse monoclonal antibodies (MAbs) that recognize ivermectin and abamectin, the major avermectins used in veterinary and agricultural formulations. Conjugates of ivermectin 4′-hemisuccinate on three different proteins were used to raise the antibodies and develop a quantitative competition enzyme immunoassay (EIA) for avermectins. The five MAbs that gave the lowest detection limits for ivermectin and abamectin were used to optimize the EIA. Several types of EIA plates, plate coating conditions, blocking agents, incubation times and temperatures, and enzyme-conjugated detecting antibodies were compared to determine acceptable assay conditions. One of the MAbs, C4D6, bound ivermectin in buffers containing up to 30% (v/v) of organic solvent. The lower limit of detection for standards in this EIA was approximately 0.5 ppb for ivermectin and 1 ppb for abamectin, with half-maximal inhibition (I50) around 3 ppb for ivermectin and 7 ppb for abamectin. The MAbs and EIA appear to be usable for quantifying avermectin residues in agricultural and environmental matrices. © 1990, American Chemical Society. All rights reserved.
引用
收藏
页码:1763 / 1770
页数:8
相关论文
共 50 条
  • [31] MONOCLONAL-ANTIBODIES
    DIAMOND, B
    SCHARFF, MD
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1982, 248 (23): : 3165 - 3169
  • [32] DETERMINATION OF SERUM HCG USING MONOCLONAL-ANTIBODIES IN ENZYME-IMMUNOASSAY
    SHIH, YS
    ROBERTS, R
    SEPHTON, T
    PADGETT, G
    TZENG, SF
    CHANG, TH
    CLINICAL CHEMISTRY, 1984, 30 (06) : 1048 - 1048
  • [33] ENZYME-IMMUNOASSAY FOR THE QUANTITATION OF SERUM HCG USING MONOCLONAL-ANTIBODIES
    WEHNER, R
    LENZ, H
    DEEG, R
    LINKE, R
    ANNALES DE BIOLOGIE CLINIQUE, 1985, 43 (04) : 595 - 595
  • [34] SANDWICH ENZYME-IMMUNOASSAY FOR ENDOTHELIN WITH MONOCLONAL-ANTIBODIES AND ITS APPLICATION
    SHIMA, H
    SAEKI, K
    YAMANOUCHI, M
    OMORI, K
    SUGIURA, M
    BIOCHEMICAL AND MOLECULAR MEDICINE, 1995, 55 (01) : 61 - 65
  • [35] SANDWICH ENZYME-IMMUNOASSAY FOR SERUM INTEGRINS USING MONOCLONAL-ANTIBODIES
    KATAYAMA, M
    KUROME, T
    YAMAMOTO, K
    UCHIDA, H
    HINO, F
    KATO, I
    CLINICA CHIMICA ACTA, 1991, 202 (03) : 179 - 190
  • [36] CHEMICAL SYNTHESIS OF BISPECIFIC MONOCLONAL-ANTIBODIES - POTENTIAL ADVANTAGES IN IMMUNOASSAY SYSTEMS
    COOK, AG
    WOOD, PJ
    JOURNAL OF IMMUNOLOGICAL METHODS, 1994, 171 (02) : 227 - 237
  • [37] PRODUCTION AND CHARACTERIZATION OF ANTI-THEOPHYLLINE MONOCLONAL-ANTIBODIES SUITABLE FOR IMMUNOASSAY
    DANILOVA, ND
    VASILOV, RG
    IMMUNOLOGY LETTERS, 1991, 28 (01) : 79 - 84
  • [38] APPLICATION OF MONOCLONAL-ANTIBODIES FOR THE QUANTITATIVE ESTIMATION OF IGE BY ENZYME-IMMUNOASSAY
    RIEKE, E
    WURZBURG, U
    HENNRICH, N
    LANG, H
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1981, 19 (08): : 814 - 814
  • [39] APPLICATION OF A SOL PARTICLE IMMUNOASSAY TO THE DETERMINATION OF AFFINITY CONSTANTS OF MONOCLONAL-ANTIBODIES
    VANERP, R
    GRIBNAU, TCJ
    VANSOMMEREN, APG
    BLOEMERS, HPJ
    JOURNAL OF IMMUNOASSAY, 1991, 12 (03): : 425 - 443
  • [40] A SANDWICH ENZYME-IMMUNOASSAY FOR COLLAGENASE INHIBITOR USING MONOCLONAL-ANTIBODIES
    KODAMA, S
    YAMASHITA, K
    KISHI, J
    IWATA, K
    HAYAKAWA, T
    MATRIX, 1989, 9 (01): : 1 - 6