POWER HV CIRCUIT-BREAKERS WITH SEVERE CAPACITIVE SWITCHING DUTY

被引:0
|
作者
CANELHAS, A
BENGTSSON, BA
MARGAARD, T
STRANDEM, A
ALVINSSON, R
机构
[1] ABB POWER SYST,DEPT HVDC SYST DESIGN,LUDVIKA,SWEDEN
[2] ABB HV SWITCHGEAR CO,DIV CIRCUIT BREAKER,LUDVIKA,SWEDEN
[3] ELSAM,DIV TRANSMISS SYST,FREDERICIA,DENMARK
关键词
3-PHASE-FAULTS; FILTER BREAKER; CAPACITIVE SWITCHING; TRV (TRANSIENT RECOVERY VOLTAGE); RESTRIKE CONDITIONS;
D O I
10.1109/61.296265
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The analysis and control of temporary overvoltages at the ac busbars of an HVDC converter station has been treated in great detail [1], [2], [3], [4]. Often it has been found necessary to operate circuit breakers to disconnect a major capacitive load from the main ac buses under severe transient overvoltage conditions. This paper describes results of tests made on a conventional puffer breaker aimed at gaining knowledge of the consequences of a restrike on the breaker itself. The paper also proposes a method to reduce the transient recovery voltage (TRV) requirements imposed on power circuit breakers in order to be able, in most of the cases, to use standard devices for capacitive breaking. The method is based on application of metal-oxide resistors in parallel with the breaker contacts. The phenomena described in this paper are in all aspects valid for any power system which can have the cases here presented. Therefore this paper is not particular only for HVDC converter stations.
引用
收藏
页码:842 / 848
页数:7
相关论文
共 50 条
  • [21] MEASUREMENTS FOR NONINVASIVE MECHANICAL DIAGNOSTICS OF POWER CIRCUIT-BREAKERS
    PARK, SY
    LAI, ML
    LIN, CC
    NAIDU, H
    SOOM, A
    REINHORN, AM
    LEE, YH
    DEMJANENKO, V
    BENENSON, DM
    SOONG, TT
    WRIGHT, SE
    ELECTRIC POWER SYSTEMS RESEARCH, 1990, 19 (01) : 1 - 10
  • [22] Modern methods for syncronous switching of circuit-breakers in 400 kV substations of the Romanian Power System
    Stroica, P
    MELECON 2000: INFORMATION TECHNOLOGY AND ELECTROTECHNOLOGY FOR THE MEDITERRANEAN COUNTRIES, VOLS 1-3, PROCEEDINGS, 2000, : 949 - 953
  • [23] DEVELOPMENT TESTS FOR CIRCUIT-BREAKERS
    HERMANN, W
    RAGALLER, K
    BROWN BOVERI REVIEW, 1979, 66 (04): : 281 - 287
  • [24] VACUUM CIRCUIT-BREAKERS ON TRIAL
    不详
    ELECTRICAL REVIEW, 1973, 193 (24): : 816 - 817
  • [25] CIRCUIT-BREAKERS PROTECT BETTER
    HIRSCH, H
    ELEKTROTECHNISCHE ZEITSCHRIFT B-AUSGABE, 1978, 30 (23): : 905 - 914
  • [26] DEVELOPMENT AND TESTING OF SF6 CIRCUIT-BREAKERS FOR HV AND EHV SYSTEMS.
    Luxa, Guenther
    Siemens power engineering, 1980, 2 (01): : 9 - 13
  • [27] FEYNMAN AMPLITUDE CIRCUIT-BREAKERS
    HAMPTON, RR
    JOURNAL OF MATHEMATICAL PHYSICS, 1980, 21 (07) : 1833 - 1841
  • [28] CIRCUIT-BREAKERS FOR EXTREME CONDITIONS
    GARRARD, CJO
    ELECTRICAL REVIEW, 1977, 201 (05): : 23 - 26
  • [29] FUSES AND CIRCUIT-BREAKERS - UPDATE
    CHIN, S
    ELECTRONIC PRODUCTS MAGAZINE, 1989, 31 (14): : 59 - 61
  • [30] Heavy current circuit-breakers
    不详
    NATURE, 1933, 131 : 103 - 104