Primary histologic diagnosis using automated whole slide imaging: a validation study

被引:134
|
作者
Gilbertson, John [1 ,5 ]
Ho, Jonhan [1 ]
Anthony, Leslie [2 ]
Jukic, Drazen [3 ,4 ]
Yagi, Yukako [1 ]
Parwani, Anil [3 ]
机构
[1] Univ Pittsburgh Med Ctr, Ctr Pathol Informat, Pittsburgh, PA 15232 USA
[2] Univ Pittsburgh, Ctr Biomed Informat, Pittsburgh, PA 15213 USA
[3] Univ Pittsburgh Sch Med, Dept Pathol, Pittsburgh, PA 15232 USA
[4] Univ Pittsburgh Sch Med, Dept Dermatol, Pittsburgh, PA 15232 USA
[5] Univ Pittsburgh Med Ctr, Benedum Ctr Oncol Informat, Pittsburgh, PA 15232 USA
来源
BMC CLINICAL PATHOLOGY | 2006年 / 6卷
关键词
D O I
10.1186/1472-6890-6-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Only prototypes 5 years ago, high-speed, automated whole slide imaging (WSI) systems (also called digital slide systems, virtual microscopes or wide field imagers) are becoming increasingly capable and robust. Modern devices can capture a slide in 5 minutes at spatial sampling periods of less than 0.5 micron/pixel. The capacity to rapidly digitize large numbers of slides should eventually have a profound, positive impact on pathology. It is important, however, that pathologists validate these systems during development, not only to identify their limitations but to guide their evolution. Methods: Three pathologists fully signed out 25 cases representing 31 parts. The laboratory information system was used to simulate real-world sign-out conditions including entering a full diagnostic field and comment (when appropriate) and ordering special stains and recuts. For each case, discrepancies between diagnoses were documented by committee and a "consensus" report was formed and then compared with the microscope-based, sign-out report from the clinical archive. Results: In 17 of 25 cases there were no discrepancies between the individual study pathologist reports. In 8 of the remaining cases, there were 12 discrepancies, including 3 in which image quality could be at least partially implicated. When the WSI consensus diagnoses were compared with the original sign-out diagnoses, no significant discrepancies were found. Full text of the pathologist reports, the WSI consensus diagnoses, and the original sign-out diagnoses are available as an attachment to this publication. Conclusion: The results indicated that the image information contained in current whole slide images is sufficient for pathologists to make reliable diagnostic decisions and compose complex diagnostic reports. This is a very positive result; however, this does not mean that WSI is as good as a microscope. Virtually every slide had focal areas in which image quality (focus and dynamic range) was less than perfect. In some cases, there was evidence of over-compression and regions made "soft" by less than perfect focus. We expect systems will continue to get better, image quality and speed will continue to improve, but that further validation studies will be needed to guide development of this promising technology.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] Impact of Whole Slide Imaging on Primary Diagnosis and Tumor Grading in Surgical Neuropathology
    Thomas, Diana
    Cevik, Lokman
    Becker, Aline
    Aslan, Mehmet
    Parwani, Anil
    Otero, Jose
    JOURNAL OF NEUROPATHOLOGY AND EXPERIMENTAL NEUROLOGY, 2020, 79 (06): : 674 - 674
  • [22] Histological Quantitation of Brain Injury Using Whole Slide Imaging: A Pilot Validation Study in Mice
    Chen, Zhenzhou
    Shin, Dmitriy
    Chen, Shanyan
    Mikhail, Kovalenko
    Hadass, Orr
    Tomlison, Brittany N.
    Korkin, Dmitry
    Shyu, Chi-Ren
    Cui, Jiankun
    Anthony, Douglas C.
    Gu, Zezong
    PLOS ONE, 2014, 9 (03):
  • [23] Diagnosis of Breast Needle Core Biopsies Using Whole Slide Imaging
    Goodman, S.
    Kandil, D.
    Khan, A.
    MODERN PATHOLOGY, 2014, 27 : 399A - 399A
  • [24] Diagnosis of Breast Needle Core Biopsies Using Whole Slide Imaging
    Goodman, S.
    Kandil, D.
    Khan, A.
    LABORATORY INVESTIGATION, 2014, 94 : 399A - 399A
  • [25] Automated Whole Slide Imaging for Conventional Optical Microscopes
    Mallawaarachchi, Sudaraka
    Wimalana, K. W. S. S.
    Liyanage, A. S.
    Premalal, G. V. A.
    Samarasinghe, Sagarika
    Nanayakkara, Nuwan D.
    2015 8TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON), 2015,
  • [26] Autofocusing technologies for whole slide imaging and automated microscopy
    Bian, Zichao
    Guo, Chengfei
    Jiang, Shaowei
    Zhu, Jiakai
    Wang, Ruihai
    Song, Pengming
    Zhang, Zibang
    Hoshino, Kazunori
    Zheng, Guoan
    JOURNAL OF BIOPHOTONICS, 2020, 13 (12)
  • [27] Rapid Validation of Whole-Slide Imaging for Primary Histopathology Diagnosis A Roadmap for the SARS-CoV-2 Pandemic Era
    Samuelson, Megan, I
    Chen, Stephanie J.
    Boukhar, Sarag A.
    Schnieders, Eric M.
    Walhof, Mackenzie L.
    Bellizzi, Andrew M.
    Robinson, Robert A.
    Rajan, Anand K. D.
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2021, 155 (05) : 638 - 648
  • [28] Whole-Slide Digital Imaging for Frozen Section Diagnosis: Phase 1 of a Validation Study, With a Focus on Image Flaws
    Plourde, Anna
    Wen, Kwun Wah
    Zhao, Larry
    Kim, Grace
    Bowman, Sarah
    Laszik, Zoltan
    LABORATORY INVESTIGATION, 2015, 95 : 507A - 507A
  • [29] Whole-Slide Digital Imaging for Frozen Section Diagnosis: Phase 1 of a Validation Study, With a Focus on Image Flaws
    Plourde, Anna
    Wen, Kwun Wah
    Zhao, Larry
    Kim, Grace
    Bowman, Sarah
    Laszik, Zoltan
    MODERN PATHOLOGY, 2015, 28 : 507A - 507A
  • [30] A New Automated Histomorphometric MATLAB Algorithm for Immunohistochemistry Analysis Using Whole Slide Imaging
    Medeiros Savi, Flavia
    Mieszczanek, Pawel
    Revert, Sophia
    Wille, Marie-Luise
    Bray, Laura Jane
    TISSUE ENGINEERING PART C-METHODS, 2020, 26 (09) : 462 - 474