CORROSION PERFORMANCE OF EPOXY-COATED REINFORCING STEEL IN MARINE SUBSTRUCTURE SERVICE

被引:29
|
作者
SAGUES, AA [1 ]
PEREZDURAN, HM [1 ]
POWERS, RG [1 ]
机构
[1] FLORIDA DEPT TRANSPORTAT,MAT OFF,GAINESVILLE,FL 32602
关键词
EPOXY; COATING; DAMAGE; CORROSION; DISBONDMENT; DELAMINATION; CONCRETE; CHLORIDE; BRIDGES; MACROCELLS; CATHODIC; POLARIZATION; MODEL; CALCULATIONS;
D O I
10.5006/1.3585202
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Corrosion of marine bridge substructures using concrete with epoxy-coated reinforcing steel (ECR) has been observed in Florida Keys' bridges. Experiments have been conducted to determine the extent of corrosion and associated macrocell action in concrete that might develop in ECR that contained surface defects and was subject to corrosion before placement in concrete. Instrumented columns have been used to measure the extent of macrocell action and determine the cathodic polarization behavior of ECR segments. A simplified quantitative model has been formulated to predict the macrocell current distribution along idealized substructure columns, as a function of concrete resistivity, column length, and ECR surface condition.
引用
收藏
页码:884 / 893
页数:10
相关论文
共 50 条
  • [41] Epoxy-coated bars as corrosion control in cracked reinforced concrete
    Lopez-Calvo, H. Z.
    Montes-Garcia, P.
    Kondratova, I.
    Bremner, T. W.
    Thomas, M. D. A.
    MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2013, 64 (07): : 599 - 608
  • [42] Tensile Bond Strength of Post-Installed Epoxy-Coated Reinforcing Bars
    Mills, Connor
    Dymond, Benjamin Z.
    JOURNAL OF BRIDGE ENGINEERING, 2021, 26 (02)
  • [43] Corrosion of Epoxy-Coated Rebar in Marine Bridges-Part 1: A 30-Year Perspective
    Saguees, A. A.
    Lau, K.
    Powers, R. G.
    Kessler, R. J.
    CORROSION, 2010, 66 (06)
  • [44] Corrosion Resistance of Epoxy-Coated 3% Cr Steel in Saline Environment Measured Using EIS and SECM
    Indira, K.
    Nishimura, T.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (01): : 419 - 431
  • [45] PERFORMANCE OF EPOXY-COATED REINFORCEMENT AT THE SERVICEABILITY LIMIT STATE
    CAIRNS, J
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 1994, 104 (01) : 61 - 73
  • [46] Cracking of concrete pavement continuously reinforced with epoxy-coated steel
    Zwerneman, FJ
    Donahey, RC
    Syed, HS
    Gunna, SR
    ACI MATERIALS JOURNAL, 1995, 92 (06) : 678 - 685
  • [47] STRENGTH PROPERTIES OF CONCRETE REINFORCED WITH EPOXY-COATED STEEL FIBERS
    KOTHARI, NC
    BONEL, EA
    JOURNAL OF THE AMERICAN CONCRETE INSTITUTE, 1978, 75 (10): : 550 - 553
  • [48] Investigation of filiform corrosion of epoxy-coated 1045 carbon steel by scanning Kelvin probe force microscopy
    Leblanc, PP
    Frankel, GS
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2004, 151 (03) : B105 - B113
  • [49] Field Performance of Epoxy Coated Reinforcing Steel in Concrete Bridge Decks in Virginia
    Pyc, W.A.
    Weyers, R.E.
    Sprinkel, M.M.
    Weyers, R.M.
    Mokarem, D.W.
    Dillard, J.G.
    Concrete International, 2000, 22 (02) : 57 - 62
  • [50] Experimental and analytical study on bond strength of normal uncoated and epoxy-coated reinforcing bars
    Wang, Xiao-Hui
    Chen, Bing
    Tang, Peng