A Fatal Complication: Intestinal Perforation Secondary to Migration of a Biliary Stent

被引:6
|
作者
Gungor, Gulay [1 ]
Okur, Nazan [2 ]
机构
[1] Kahramanmaras Necip Fazil Sehir Hastanesi, Dept Radiol, Kahramanmaras, Turkey
[2] Afyon Kocatepe Univ, Tip Fak, Dept Radiol, Afyon, Turkey
关键词
Biliary Tract; Intestinal Perforation; Multidetector Computed Tomography; Stents;
D O I
10.12659/PJR.896231
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Stent insertion is widely performed to restore biliary drainage in hepatic, biliary, and pancreatic obstructive conditions. Intestinal perforation due to the migration of these stents is an extremely rare late-term complication that is associated with a high rate of mortality. The current report aimed at presenting the radiological findings of a case of extraluminal biliary stent migration into the pelvic region that caused intestinal perforation. Case Report: We report a case of an 85-year-old male with a history of previous stent insertion who presented with a sudden - onset severe abdominal pain. An abdominal multidetector computed tomography (MDCT) revealed a tubular foreign body density, compatible with intestinal perforation due to migration of the biliary stent. Conclusions: Biliary stent insertion becomes a more common procedure. This serious complication must always be remembered in patients presenting with abdominal pain after stent insertion.
引用
收藏
页码:170 / 172
页数:3
相关论文
共 50 条
  • [31] Intestinal perforation in a parastomal hernia by a migrated plastic biliary stent
    Patel, SN
    Levey, JM
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2002, 97 (09): : S150 - S150
  • [32] Plastic biliary stent migration as a cause of ascending colon perforation
    Vergara-Fernandez, Omar
    Tueme-De la Pena, Danilo
    Canto-Losa, Jorge Eduardo
    REVISTA ESPANOLA DE ENFERMEDADES DIGESTIVAS, 2022, 116 (05) : 283 - 284
  • [33] Percutaneous retrieval of a biliary stent after migration and ileal perforation
    Culnan D.M.
    Cicuto B.J.
    Singh H.
    Cherry R.A.
    World Journal of Emergency Surgery, 4 (1)
  • [34] Bowel Perforation Caused by Biliary Stent Migration After ERCP
    Wilson, Natalie
    Ezeani, Chukwunonso
    Ismail, Abdellatif
    Abdalla, Monzer
    Mohammed, Shaikhoon
    Abdalla, Abubaker
    Elawad, Ayman
    Beran, Azizullah
    Jaber, Fouad
    Abosheaishaa, Hazem
    Loon, Erica
    Abdallah, Mohamed
    Vargo, John
    Bilal, Mohammad
    Chahal, Prabhleen
    JOURNAL OF CLINICAL GASTROENTEROLOGY, 2025, 59 (05) : 472 - 478
  • [35] Double Sigmoid colon perforation due to migration of a biliary stent
    Malgras, B.
    Pierret, C.
    Tourtier, J. -P.
    Olagui, G.
    Nizou, C.
    Duverger, V.
    JOURNAL OF VISCERAL SURGERY, 2011, 148 (05) : E397 - E399
  • [36] Primary Endoscopic Closure of Duodenal Perforation Secondary to Biliary Stent Migration: A Case Report and Review of the Literature
    Ferm, Samson
    Fisher, Constantine
    Hassam, Akil
    Rubin, Moshe
    Kim, Sang-Hoon
    Hussain, Syed Ahsan
    JOURNAL OF INVESTIGATIVE MEDICINE HIGH IMPACT CASE REPORTS, 2018, 6
  • [37] Intraperitoneal duodenal perforation secondary to early migration of biliary stent: closure with through-the-scope clip
    Jadallah, Khaled
    Alzubi, Bara
    Sweidan, Aroob
    Almanasra, Abdel R.
    BMJ CASE REPORTS, 2019, 12 (09)
  • [38] Descending Stent, Ascending Cholangitis; Biliary Sepsis Secondary to Stent Migration
    Donlan, C.
    Myers, E.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2014, 183 : S125 - S125
  • [39] Silent duodenocolic fistula secondary to biliary stent migration
    Ha, Joe Ping-Yiu
    Leung, Lik-Hang
    Tang, Chung-Ngai
    Li, Michael Ka-Wah
    SURGICAL PRACTICE, 2007, 11 (03) : 127 - 129
  • [40] An unusual complication of a biliary stent - Small bowel perforation of an incarcerated hernia sac
    Mastorakos, DP
    Milman, PJ
    Cohen, R
    Goldenberg, SP
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 1998, 93 (12): : 2533 - 2535