ENERGY DEPOSITION IN X-RAY CCDS AND CHARGED-PARTICLE DISCRIMINATION

被引:4
|
作者
OWENS, A
MCCARTHY, KJ
机构
[1] Department of Physics and Astronomy, University of Leicester, Leicester
关键词
D O I
10.1016/0168-9002(95)00603-6
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report the results of investigation into ionization energy loss in X-ray CCDs and the ability of fast protons to masquerade as X-ray events by their energy and spatial signatures. The study was made to explore background contamination in X-ray detectors intended to operate in the mixed radiation environment of space. It was carried out using the ionization energy loss code of Hall [1] which includes atomic electron binding effects. Three devices were considered in our study; a front illuminated 35 mu m deep depletion device developed for the Joint European X-ray Telescope, and two CCDs baselined for ESA's XMM mission - a PN device of active depth 280 mu m and a back-illuminated MOS device of active depth 90 mu m It was found that for the JET-X device, 4.9% of minimally ionizing protons deposit less than 10 keV in the active volume of the CCD. Whilst the frequency distribution of such events versus energy deposited increases up to a peak energy of similar to 9 keV, the number having a morphology consistent with X-ray events simultaneously decreases. Thus, when coupled with the requirement that events should extend no more than 2 pixels spatially, the fraction of masquerading events drops to 0.016%. The analysis was also carried out for the two XMM CCDs. For the PN device the fraction of events depositing less than 15 keV is miniscule whereas almost 4% of events were recorded for the MOS device. When coupled with an event size requirement of less than or equal to 2 pixels, the fraction of events falls to 1 X 10(-9). A surprising result of the present work is that the ability of a CCD to discriminate against minimally ionizing particles is dependent on pixel size. For a JET-X like device this varies by a factor 10 for pixel sizes ranging from 13 to 35 mu m on a side. In fact, the optimum pixel size for both the JET-X and XMM MOS devices was found to be near 40 mu m. We conclude that given the energy deposition and morphological distinctions between photon and particle events, CCDs used in X-ray astronomy can be optimally designed to provide simultaneously the highest signal-to-noise ratios for X-rays and rejection ratios for charged particles.
引用
收藏
页码:148 / 154
页数:7
相关论文
共 50 条
  • [1] Exploration of X-ray and charged-particle spectroscopy with CCDs and PSDs
    Simons, DPL
    Mutsaers, PHA
    van Ijzendoorn, LJ
    de Voigt, MJA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1998, 139 (1-4): : 273 - 278
  • [2] Exploration of X-ray and charged-particle spectroscopy with CCDs and PSDs
    Eindhoven Univ of Technology, Eindhoven, Netherlands
    Nucl Instrum Methods Phys Res Sect B, 1-4 (273-278):
  • [3] CHARGED-PARTICLE INDUCED X-RAY ANALYSIS OF DRINKING-WATER
    MITTLER, A
    BARNES, BK
    KEGEL, GHR
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1975, 20 (04): : 685 - 685
  • [4] A STATISTICAL-ANALYSIS OF ULTRAVIOLET, X-RAY, AND CHARGED-PARTICLE LITHOGRAPHIES
    SMITH, HI
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1986, 4 (01): : 148 - 153
  • [5] CHARGED-PARTICLE ACTIVATION-ANALYSIS COUPLED WITH X-RAY COUNTING
    MCGINLEY, JR
    SCHWEIKE.EA
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1973, 16 (02): : 385 - 394
  • [6] MULTIELEMENT CHARGED-PARTICLE ACTIVATION-ANALYSIS WITH X-RAY COUNTING
    MCGINLEY, JR
    SCHWEIKERT, EA
    ANALYTICAL CHEMISTRY, 1976, 48 (02) : 429 - 435
  • [7] CHARGED-PARTICLE INDUCED X-RAY ANALYSIS OF LUBRICATING OIL SAMPLES
    BARNES, BK
    KEGEL, GHR
    MITTLER, A
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1975, 20 (04): : 685 - 685
  • [8] CHARGED-PARTICLE MASS AND ENERGY DEPOSITION IN A THERMONUCLEAR PLASMA
    ANTAL, MJ
    DANA, AL
    LEE, CE
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1975, 20 (04): : 683 - 683
  • [9] CHARGED-PARTICLE INDUCED X-RAY ANALYSIS OF MALARIA INFECTED BLOOD SAMPLES
    BARNES, BK
    COLEMAN, RM
    KEGEL, GHR
    MITTLER, A
    QUINN, P
    RENCRICCA, NJ
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1975, 20 (02): : 226 - 226
  • [10] CHARGED-PARTICLE INDUCED X-RAY ANALYSIS - NEW TOOL IN FORENSIC SCIENCE
    BARNES, BK
    BEGHIAN, LE
    KEGEL, GHR
    MATHUR, SC
    QUINN, P
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1973, 15 (01): : 13 - 25