Minimally Invasive Dynamic Hip Screw Fixation in Stable and Unstable Intertrochanteric Fractures

被引:0
|
作者
Jana, Kanailal [1 ]
Jha, Dipak Kumar [1 ]
Chakraburtty, Tapas [1 ]
Mullick, Sunny Kumar [1 ]
Duttagupta, Swarnava [1 ]
机构
[1] Vivekananda Inst Med Sci, Dept Orthopaed, Kolkata, W Bengal, India
关键词
Dynamic hip screw; Intertrochanteric; Minimally invasive;
D O I
10.17354/ijss/2016/529
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Introduction: In minimally invasive dynamic hip screw (DHS) fixation procedure, we have found a lesser amount of blood loss compared to the conventional DHS fixation. It is probably due to less soft tissue dissection and less exposure of the fracture fragments. Objectives: To evaluate peroperative blood loss, duration of operation, duration of hospital stay in patients with stable and unstable intertrochanteric fractures. Materials and Methods: Of 29 patients, 20 stable and nine unstable intertrochanteric fracture treated by minimally invasive DHS fixation. Peroperative average blood loss, post-operative hemoglobin (Hb) reductions, duration of surgery, and duration of hospital stay were studied. Results: Average blood loss was 64 ml and post-operative Hb reduction was 1.1 g. Average wound size 3.5 cm. A mean duration of surgery 52 min and average duration of post-operative hospital stay was 6 days. Conclusion: Minimally invasive DHS fixation is technically demanding with advantages of less blood loss, minimum soft tissue dissection, and shorter duration of hospital stay in stable and unstable intertrochanteric fractures.
引用
收藏
页码:71 / 74
页数:4
相关论文
共 50 条
  • [41] STABLE FIXATION IN INTERTROCHANTERIC HIP FRACTURES - BIOMECHANICAL EVALUATION
    SONSTEGA.DA
    MATTHEWS, LS
    KAUFER, H
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (03): : 660 - &
  • [42] External fixation of select intertrochanteric fractures with single hip screw
    Christodoulou, NA
    Sdrenias, CV
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2000, (381) : 204 - 211
  • [43] THE MANAGEMENT OF INTERTROCHANTERIC FRACTURES OF FEMUR BY DYNAMIC HIP SCREW
    Singh, Arvinder
    [J]. JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2014, 3 (74): : 15575 - 15579
  • [44] Comparison of Dynamic Hip Screw and Proximal Femoral Nailing Techniques in Stable Intertrochanteric Fractures
    Shiraz, Salman
    Shujauddin, Mohammad
    Hasan, Khalid
    Elramadi, Ahmed
    Ahmed, Ghalib
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (01)
  • [45] Proximal femoral locking plate versus dynamic hip screw for unstable intertrochanteric femoral fractures
    Upadhyay, Sachin
    Raza, H. K. T.
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY, 2014, 22 (01) : 130 - 131
  • [46] Proximal femoral locking plate versus dynamic hip screw for unstable intertrochanteric femoral fractures
    Dhamangaonkar, Anoop C.
    Joshi, Deepak
    Goregaonkar, Arvind B.
    Tawari, Akhil A.
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY, 2013, 21 (03) : 317 - 322
  • [47] Dynamic Hip Screw Compared to Condylar Blade Plate in the Treatment of Unstable Fragility Intertrochanteric Fractures
    Yong, C. K.
    Tan, C. N.
    Penafort, R.
    Singh, D. A.
    Varaprasad, M. V.
    [J]. MALAYSIAN ORTHOPAEDIC JOURNAL, 2009, 3 (01) : 13 - 18
  • [48] UNSTABLE INTERTROCHANTERIC FRACTURES OF HIP
    DIMON, JH
    HUGHSTON, JC
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1966, A 48 (05): : 1020 - &
  • [49] UNSTABLE INTERTROCHANTERIC FRACTURES OF HIP
    DIMON, JH
    HUGHSTON, JC
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1967, A 49 (03): : 440 - &
  • [50] UNSTABLE INTERTROCHANTERIC FRACTURES OF THE HIP
    HUGHSTON, JC
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1964, 46 (05): : 1145 - 1145