ENZYME-IMMUNOASSAY FOR PLASMA ESTRADIOL USING A MONOCLONAL-ANTIBODY

被引:10
|
作者
ELJABRI, J
机构
[1] UFR Biomédicale des Saints-Pères, Départment de Biochimie, porte R 283, 45 rue des Saints-Pères
关键词
D O I
10.1016/0960-0760(91)90105-E
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A microtitre plate enzyme immunoassay (EIA) for plasma estradiol is described, involving competition between sample estradiol and an immobilized estradiol-bovine serum albumin complex for a monoclonal anti-estradiol antibody, followed by immobilized antibody quantitation using enzyme-labelled antiglobulins. The assay dose-response curve covered a range of 6-1500 fmol/well. The intra- and inter-assay coefficient of variation for the assay of three plasma pools ranged from 3.1 to 4.7% and from 4.7 to 10.6% respectively. The assay showed satisfactory correlation with a standard estradiol radioimmunoassay. Pre-coated microtitre plates were stable, dried, at 4-degrees-C for up to 3 months and the anti-estradiol was stable to lyophilization and also was stable in solution at 4-degrees-C for up to 1 month.
引用
收藏
页码:339 / 343
页数:5