PULMONARY MECHANICS IN PRETERM NEONATES WITH RESPIRATORY-FAILURE TREATED WITH HIGH-FREQUENCY OSCILLATORY VENTILATION COMPARED WITH CONVENTIONAL MECHANICAL VENTILATION

被引:0
|
作者
ABBASI, S
BHUTANI, VK
SPITZER, AR
FOX, WW
机构
[1] UNIV PENN,SCH MED,PHILADELPHIA,PA 19104
[2] CHILDRENS HOSP,PHILADELPHIA,PA 19104
关键词
CMV; CONVENTIONAL MECHANICAL VENTILATION; HFOV; HIGH-FREQUENCY OSCILLATORY VENTILATION; BPD; BRONCHOPULMONARY DYSPLASIA; HIFI; HIGH FREQUENCY;
D O I
暂无
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Pulmonary mechanics were measured in 43 preterm neonates (mean +/- SD values of birth weight 1.2 +/- 0.3 kg, gestational age 30 +/- 2 weeks) with respiratory failure who were concurrently randomly assigned to receive conventional mechanical ventilation (n = 22) or high-frequency ventilation (n = 21). The incidence of bronchopulmonary dysplasia was comparable in the two groups (high-frequency ventilation 57%, conventional ventilation 50%). Pulmonary functions were determined at 0.5, 1.0, 2.0, and 4.0 weeks postnatal ages. Data were collected while subjects were in a nonsedated state during spontaneous breathing. These sequential data show similar patterns of change in pulmonary mechanics during high-frequency ventilation and conventional mechanical ventilation irrespective of gestational age, birth weight stratification, or bronchopulmonary dysplasia. There was no significant difference in the pulmonary functions with either mode of ventilation during the acute phase (less-than-or-equal-to 4 weeks) of respiratory disease. When evaluated by the clinical diagnosis of bronchopulmonary dysplasia, the pulmonary data suggested a less severe dysfunction in the high-frequency oscillatory ventilation-treated bronchopulmonary dysplasia group compared with the conventional mechanical ventilation-treated group. These results indicate that high-frequency oscillatory ventilation in preterm neonates does not reduce the risk of acute lung injury; however, the magnitude of the pulmonary dysfunction in the first 2 weeks of life merits a reevaluation.
引用
收藏
页码:487 / 493
页数:7
相关论文
共 50 条
  • [41] Respiratory mechanics during high-frequency oscillatory ventilation: a physical model and preterm infant study
    Singh, Rachana
    Courtney, Sherry E.
    Weisner, Michael D.
    Habib, Robert H.
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2012, 112 (07) : 1105 - 1113
  • [42] High-frequency oscillatory ventilation versus conventional positive-pressure ventilation in neonates.
    Vialet, R
    Lagier, P
    Casha, P
    Dejode, JM
    Soula, F
    Martin, C
    [J]. ANNALES DE PEDIATRIE, 1996, 43 (02): : 99 - 107
  • [43] HIGH-FREQUENCY VENTILATION IN 10 CHILDREN WITH ACUTE RESPIRATORY-FAILURE
    OROURKE, PP
    CRONE, RK
    [J]. CRITICAL CARE MEDICINE, 1983, 11 (03) : 222 - 222
  • [44] ROLE OF HIGH-FREQUENCY JET VENTILATION IN THE MANAGEMENT OF RESPIRATORY-FAILURE
    CARLON, GC
    HOWLAND, WS
    GROEGER, JS
    RAY, C
    MIODOWNIK, S
    [J]. CRITICAL CARE MEDICINE, 1984, 12 (09) : 777 - 779
  • [45] HIGH-FREQUENCY OSCILLATORY VENTILATION IN PREMATURE-INFANTS WITH RESPIRATORY-FAILURE - A PRELIMINARY-REPORT
    FROESE, AB
    BUTLER, PO
    FLETCHER, WA
    BYFORD, LJ
    [J]. ANESTHESIA AND ANALGESIA, 1987, 66 (09): : 814 - 824
  • [46] THE USE OF HIGH-FREQUENCY JET VENTILATION DURING RESPIRATORY-FAILURE
    SCHUSTER, DP
    SNYDER, JV
    KLAIN, M
    GRENVIK, A
    [J]. CRITICAL CARE MEDICINE, 1981, 9 (03) : 162 - 162
  • [47] High-frequency oscillatory ventilation is not superior to conventional mechanical ventilation in surfactant-treated rabbits with lung injury
    Gommers, D
    Hartog, A
    Schnabel, R
    De Jaegere, A
    Lachmann, B
    [J]. EUROPEAN RESPIRATORY JOURNAL, 1999, 14 (04) : 738 - 744
  • [48] High-frequency oscillation ventilation for hypercapnic failure of conventional ventilation in pulmonary acute respiratory distress syndrome
    Friesecke, Sigrun
    Stecher, Stephanie-Susanne
    Abel, Peter
    [J]. CRITICAL CARE, 2015, 19
  • [49] High-frequency oscillation ventilation for hypercapnic failure of conventional ventilation in pulmonary acute respiratory distress syndrome
    Sigrun Friesecke
    Stephanie-Susanne Stecher
    Peter Abel
    [J]. Critical Care, 19
  • [50] High-frequency oscillatory ventilation versus conventional mechanical ventilation in congenital diaphragmatic hernia
    Cacciari, A
    Ruggeri, G
    Mordenti, M
    Ceccarelli, PL
    Baccarini, E
    Pigna, A
    Gentili, A
    [J]. EUROPEAN JOURNAL OF PEDIATRIC SURGERY, 2001, 11 (01) : 3 - 7