ABILITY OF THE CAROTID DUPLEX SCAN TO PREDICT STENOSIS, SYMPTOMS, AND PLAQUE STRUCTURE

被引:0
|
作者
HILL, SL [1 ]
DONATE, AT [1 ]
机构
[1] COMMUNITY HOSP ROANOKE VALLEY,DEPT SURG,ROANOKE,VA
关键词
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background. The duplex scan with its improved technology has allowed clinicians to visualize noninvasively the carotid bifurcation. We investigated whether the duplex scan, with its ability to visualize plaque structure, can reliably predict the major components of different plaques seen in pathologic studies. Furthermore, we studied whether it could correlate these findings with the presenting symptoms of patients and predict which patients would benefit from early endarterectomy. Methods. We performed a retrospective study of 84 patients during a 43-month period. The arteriogram, duplex scans, symptoms, and pathologic examination of the carotid atheroma in each patient were reviewed. The specimens were divided into three categories depending on the major component found in pathologic studies. One group consisted of calcific plaques, another was predominantly fibrosis and cholesterol, and the third was plaques with intramural hemorrhage. The angiograms and duplex scans were separately interpreted. Patients with symptoms (81%) were divided into those amaurosis fugax (19%), transient ischemic attacks (58%), and cerebral vascular accidents (3%). Results. The agreement between duplex scan findings and arteriograms concerning the percent stenosis was 95%. There was no correlation, however, between the presence or type of symptoms and the plaque structure as seen in pathologic studies or on the duplex scan. Conclusions. At this stage of technology the duplex scan is most reliable in detecting hemodynamically significant lesions. Its ability to predict symptoms or finding at surgery and possibly to alter treatment is at best limited.
引用
收藏
页码:914 / 920
页数:7
相关论文
共 50 条
  • [21] Sex differences in carotid plaque and stenosis
    Iemolo, F
    Martiniuk, A
    Steinman, DA
    Spence, JD
    STROKE, 2004, 35 (02) : 477 - 481
  • [22] Atherosclerotic plaque rupture and intraplaque hemorrhage do not correlate with symptoms in carotid artery stenosis
    Milei, J
    Parodi, JC
    Ferreira, M
    Barrone, A
    Grana, DR
    Matturri, L
    JOURNAL OF VASCULAR SURGERY, 2003, 38 (06) : 1241 - 1247
  • [23] Duplex scan sonography of renal artery stenosis
    Rabbia, C
    Valpreda, S
    INTERNATIONAL ANGIOLOGY, 2003, 22 (02) : 101 - 115
  • [24] POSTOPERATIVE CAROTID DUPLEX SCAN AND OCULAR PNEUMOPLETHYSMOGRAPHY
    GEE, W
    JOURNAL OF VASCULAR SURGERY, 1989, 9 (03) : 508 - 508
  • [25] Predictive ability of duplex ultrasonography for internal carotid artery stenosis of 70%-99%: A comparative study
    Chen, JC
    Salvian, AJ
    Taylor, DC
    Teal, PA
    Marotta, TR
    Hsiang, YN
    ANNALS OF VASCULAR SURGERY, 1998, 12 (03) : 244 - 247
  • [26] Accuracy of duplex scan of internal carotid arteries
    Knudsen, L
    Johansen, A
    Justesen, P
    Jorgensen, HB
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2002, 24 (01) : 86 - 87
  • [27] Lack of precision of duplex scan velocity measurements can falsely elevate rates of progression of carotid stenosis
    Archie, JP
    JOURNAL OF VASCULAR SURGERY, 1999, 30 (02) : 385 - 386
  • [28] Internal carotid artery stenosis -: Comparison of duplex scan and magnetic resonance angiography with digital subtraction angiography
    Py, MO
    André, C
    de Azevedo, FS
    Domingues, RC
    Salomao, RF
    ARQUIVOS DE NEURO-PSIQUIATRIA, 2001, 59 (3B) : 665 - 671
  • [29] OCULAR SYMPTOMS IN CAROTID STENOSIS
    SCHLIETER, F
    SZEPAN, B
    BAUMGART, W
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1976, 169 (02) : 273 - 274
  • [30] Duplex US for the estimation of internal carotid stenosis
    Vergara, M
    RADIOLOGY, 2001, 219 (02) : 575 - 576