PERCUTANEOUS RENAL BIOPSY WITH THE USE OF REAL-TIME ULTRASOUND

被引:51
|
作者
BURSTEIN, DM
SCHWARTZ, MM
KORBET, SM
机构
[1] RUSH MED COLL,DEPT MED,CHICAGO,IL 60612
[2] RUSH MED COLL,DEPT PATHOL,CHICAGO,IL 60612
关键词
PERCUTANEOUS RENAL BIOPSY; REAL-TIME ULTRASOUND;
D O I
10.1159/000168303
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
We describe our experience with real-time ultrasound as a localization and guidance tool for percutaneous renal biopsy. Two hundred biopsies performed between June 1983 and January 1990 were reviewed retrospectively. Nephrology fellows performed 83.5% of the biopsies. The average age of the patients was 43 +/- 17 years (range 6-80) and renal insufficiency (serum creatinine greater-than-or-equal-to 1.3 mg, %) was present in approximately 60% of patients biopsied. Primary indications for biopsy were to evaluate proteinuria (46.5%) and renal manifestation of systemic lupus erythematosus (24%). Material for light microscopy, immunofluorescence, and electron microscopy was obtained in 99.5, 95.0 and 98.0% of cases, respectively. Adequate tissue for histologic diagnosis was obtained in 97.5% of patients. Primary diagnosis was glomerulonephritis in 77.9% of cases. Complications were assessed and separated by severity. Total complications were observed in 13.7% of patients with 8.1% of these being minor complications (not requiring blood transfusion) and 5.6% being major complications which required blood transfusions. Bleeding complications requiring massive blood transfusion and/or therapeutic radiologic intervention were seen in 1.5% of patients. We could find no significant difference with respect to age, serum creatinine, or coagulation parameters between patients with or without complications due to percutaneous renal biopsy. We conclude that real-time ultrasound is a safe, accurate method in localizing the kidney for percutaneous renal blopsy. However, patients must still be observed carefully post biopsy for potential complications.
引用
收藏
页码:195 / 200
页数:6
相关论文
共 50 条
  • [41] CLINICAL USE OF THE PERCUTANEOUS RENAL BIOPSY
    ARNOLD, JD
    SPARGO, B
    CIRCULATION, 1959, 19 (04) : 609 - 621
  • [42] Use of real-time ultrasound in the management of scrotal trauma
    Lewis, C.A.
    Michell, M.J.
    British Journal of Radiology, 1991, 64 (765):
  • [43] THE USE OF REAL-TIME ULTRASOUND TO ENHANCE FETOSCOPIC VISUALIZATION
    SCHWARTZ, DB
    ZWEIBEL, WJ
    ZAGZEBSKI, J
    ARBOGAST, RL
    DONOVAN, D
    JOURNAL OF CLINICAL ULTRASOUND, 1983, 11 (03) : 161 - 164
  • [44] THE ROUTINE USE OF REAL-TIME ULTRASOUND IN ABDOMINAL EXAMINATIONS
    ROSENBERG, ER
    BOWIE, JD
    CLAIR, MR
    HIDALGO, H
    RAM, PC
    MEDICAL ULTRASOUND, 1983, 7 (01) : 1 - 5
  • [45] USE OF REAL-TIME ULTRASOUND SCANNING IN NEUROSURGICAL OPERATIONS
    RUBIN, JM
    DOHRMANN, GJ
    ANNALS OF NEUROLOGY, 1982, 12 (01) : 90 - 90
  • [46] THE USE OF REAL-TIME ULTRASOUND IN THE MANAGEMENT OF SCROTAL TRAUMA
    LEWIS, CA
    MICHELL, MJ
    BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (765): : 792 - 795
  • [47] THE USE OF REAL-TIME ULTRASOUND IN THE MANAGEMENT OF OBSTETRIC EMERGENCIES
    DAVIS, RO
    BRUMFIELD, CG
    CLINICAL OBSTETRICS AND GYNECOLOGY, 1984, 27 (01): : 68 - 77
  • [48] PERCUTANEOUS DRAINAGE OF ABDOMINAL ABSCESSES UNDER REAL-TIME ULTRASOUND GUIDANCE
    BONNEL, D
    CORNUD, F
    LACAINE, F
    CARETTE, MF
    SIBERT, A
    BENACERRAF, R
    BIGOT, JM
    GASTROENTEROLOGIE CLINIQUE ET BIOLOGIQUE, 1985, 9 (11): : 824 - 828
  • [49] Learning curve for real-time ultrasound-guided percutaneous tracheostomy
    Petiot, Sandra
    Guinot, Pierre-Gregoire
    Diouf, Momar
    Zogheib, Elie
    Dupont, Herve
    ANAESTHESIA CRITICAL CARE & PAIN MEDICINE, 2017, 36 (05) : 279 - 283
  • [50] Adequacy of percutaneous non-targeted liver biopsy under real-time ultrasound guidance when comparing the Biopince™ and Achieve™ biopsy needle
    Hall, Thomas C.
    Deakin, Claire
    Atwal, Gurprit S. S.
    Singh, Rajeev K.
    BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1080):