Long-Term Follow-Up of Endocardial Pacing Leads Implanted with Extrathoracic Subclavian Venous Approach

被引:0
|
作者
Ohnuki, Masahiro [1 ]
Miyataka, Kazuhiko [1 ]
Nakamura, Takehiko [2 ]
Ohnishi, Yoshinobu [3 ]
Kohnoike, Yoshizumi [4 ]
Tsujimoto, Masayuki [4 ]
Shirayama, Reirou [5 ]
机构
[1] Saiseikai Chuwa Hosp, Dept Cardiol, Abe 323, Sakurai, Nara, Japan
[2] Takita Hosp, Dept Internal Med, Nara, Japan
[3] Tenri City Hosp, Dept Internal Med, Tenri, Nara, Japan
[4] Heisei Mem Hosp, Dept Internal Med, Unnan, Japan
[5] Nara City Hosp, Dept Internal Med, Nara, Japan
关键词
Pacemaker; Endocardial lead; Lead failure; Lead survival;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The extrathoracic subclavian venous approach is a new approach with the aim to exclude the disadvantages of the conventional subclavian venous approach that carries a risk of pneumothorax and may result in lead damage. We investigated long-term survival of the leads implanted by this new approach between May 1995 and June 2005. A total of 482 leads implanted in 309 patients were analyzed. In cases of patient death, meeting criteria for lead failure or difficulty of continuing follow-up for other reasons, the follow-up was terminated at that time. Therefore, the follow-up was complete for 358 leads (74.3%) and the mean follow-up time was 55.0 +/- 32.1 months (range 1-122 months). The overall lead survival rate was 100% at 5 years and 98.3% at 7 years. This finding suggested that this approach might reduce the incidence of lead failure.
引用
收藏
页码:110 / 114
页数:5
相关论文
共 50 条
  • [31] Postmortem analysis of encapsulation around long-term ventricular endocardial pacing leads
    Candinas, R
    Duru, F
    Schneider, J
    Lüscher, TF
    Stokes, K
    MAYO CLINIC PROCEEDINGS, 1999, 74 (02) : 120 - 125
  • [32] Canadian trial of physiological pacing - Effects of physiological pacing during long-term follow-up
    Kerr, CR
    Connolly, SJ
    Abdollah, H
    Roberts, RS
    Gent, M
    Yusuf, S
    Gillis, AM
    Tang, ASL
    Talajic, M
    Klein, GJ
    Newman, DM
    CIRCULATION, 2004, 109 (03) : 357 - 362
  • [33] PERMANENT PACING IN CHILDREN - ACUTE LEAD IMPLANTATION AND LONG-TERM FOLLOW-UP
    SERWER, GA
    PROGRESS IN PEDIATRIC CARDIOLOGY, 1995, 4 (01) : 31 - 41
  • [34] Long-term follow-up of atrioventricular delay optimization in patients with biventricular pacing
    Inoue, N
    Ishikawa, T
    Sumita, S
    Nakagawa, T
    Kobayashi, T
    Matsushita, K
    Matsumoto, K
    Ohkusu, Y
    Taima, M
    Kosuge, M
    Uchino, K
    Kimura, K
    Umemura, S
    CIRCULATION JOURNAL, 2005, 69 (02) : 201 - 204
  • [35] Long-term follow-up of selective and non-selective His bundle pacing leads in patients with atrioventricular block
    Frausing, Maria Hee Jung Park
    Baek, Aleksander Laust
    Kristensen, Jens
    Gerdes, Christian
    Nielsen, Jens Cosedis
    Kronborg, Mads Brix
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2023, 66 (08) : 1849 - 1857
  • [36] Long-term follow-up of selective and non-selective His bundle pacing leads in patients with atrioventricular block
    Maria Hee Jung Park Frausing
    Aleksander Laust Bæk
    Jens Kristensen
    Christian Gerdes
    Jens Cosedis Nielsen
    Mads Brix Kronborg
    Journal of Interventional Cardiac Electrophysiology, 2023, 66 : 1849 - 1857
  • [37] Long-Term Follow-Up of Patients with Relatively High Effective Defibrillation Threshold during Cardioverter Defibrillator Implantation with Endocardial Leads
    Rosenheck, Shimon
    Sharon, Zehava
    Weiss, Alexey
    CARDIOLOGY, 2009, 112 (02) : 107 - 113
  • [38] Long-Term Follow-Up of Implanted Children with Cytomegalovirus-Related Deafness
    Viccaro, Marika
    Filipo, Roberto
    Bosco, Ersilia
    Nicastri, Maria
    Mancini, Patrizia
    AUDIOLOGY AND NEURO-OTOLOGY, 2012, 17 (06) : 395 - 399
  • [39] LONG-TERM FOLLOW-UP OF POLYURETHANE DEGRADABLE VASCULAR PROSTHESIS IMPLANTED IN PIGS
    GALLETTI, G
    USSIA, G
    FARRUGGIA, F
    GOGOLEWSKI, S
    ARTIFICIAL ORGANS, 1987, 11 (04) : 342 - 342
  • [40] LONG-TERM FOLLOW-UP OF 2 INFANTS WITH AN IMPLANTED CARDIAC-PACEMAKER
    GRIFFITHS, SP
    HAYES, CJ
    BOWMAN, FO
    GERSONY, WM
    AMERICAN JOURNAL OF CARDIOLOGY, 1975, 36 (07): : 921 - 924