USE OF ULTRA-THIN WINDOW DETECTORS FOR BIOLOGICAL MICROANALYSIS

被引:0
|
作者
MARSHALL, AT
PATAK, A
机构
关键词
QUANTITATIVE X-RAY MICROANALYSIS; LIGHT ELEMENT ANALYSIS; ULTRA-THIN WINDOW DETECTORS; BIOLOGICAL; PHI-RHO-ZED MODEL; ZAF; PEAK TO CONTINUUM RATIO; RATIO METHOD; FROZEN-HYDRATED; THIN SECTIONS; BULK SAMPLES;
D O I
暂无
中图分类号
TH742 [显微镜];
学科分类号
摘要
Films and bulk samples of Nylon, gelatin, Makrofol, epoxy resin, aminoplastic resin and sodium acetate have been used as models of biological samples. It is shown that the use of ultrathin window (UTW) detectors in scanning transmission and scanning electron microsopes permits the quantitative analysis of light elements, yielding a total element analysis with hydrogen estimated by difference or ''guesstimated''. Comparison with known concentrations or concentrations obtained by chemical analysis shows that X-ray microanalysis of sections by the peak to continuum ratio model and bulk samples by the phi(pz) model gives sufficiently accurate results for biological purposes. It is also shown that sections may be analysed by the standardless ratio model. The application of UTW detectors to total element analysis by quantitative elemental imaging is demonstrated of bulk biological samples, which have been freeze-substituted, embedded in epoxy resin and surface polished. The possibility of imaging the oxygen content of frozen-hydrated bulk tissue samples which have been surface polished is also demonstrated. This may lead to the imaging of water distribution in frozen-hydrated bulk samples of biological tissues. UTW detectors are also useful for detecting mass loss in organic samples by monitoring the decrease in oxygen counts and for detecting contamination by monitoring the increase in carbon counts. It is also shown that changes in carbon counts are good indicators of folds in sections.
引用
收藏
页码:677 / 691
页数:15
相关论文
共 50 条
  • [31] Ultra-thin ferroelectrics
    Qiao, Huimin
    Wang, Chenxi
    Choi, Woo Seok
    Park, Min Hyuk
    Kim, Yunseok
    MATERIALS SCIENCE & ENGINEERING R-REPORTS, 2021, 145
  • [32] Ultra-thin stereolithography
    Engineering (London), 1997, 238 (06):
  • [33] An ultra-thin Schottky diode as a transmission particle detector for biological microbeams
    Grad, M.
    Harken, A.
    Randers-Pehrson, G.
    Attinger, D.
    Brenner, D. J.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [34] A device for trimming frozen biological tissue preparatory to ultra-thin sectioning
    Hodson, Stuart
    Marshall, J.
    JOURNAL OF MICROSCOPY, 1969, 89 : 373 - 375
  • [35] The Use of an Ultra-Thin Instrument for Difficult Colonoscopy in Unsedated Patients
    Togashi, Kazutomo
    Nemoto, Daiki
    Hewett, David G.
    Sunada, Keijiro
    Yamamoto, Hironori
    GASTROINTESTINAL ENDOSCOPY, 2012, 75 (04) : 283 - 283
  • [36] Detailed analysis of chemical corrosion of ultra-thin wires used in drift chamber detectors
    Baldini, A. M.
    Cavoto, G.
    Cei, F.
    Chiappini, M.
    Chiarello, G.
    Chiri, C.
    Cocciolo, G.
    Corvaglia, A.
    Cuna, F.
    Francesconi, M.
    Galli, L.
    Grancagnolo, F.
    Grassi, M.
    Ishak, R.
    Meucci, M.
    Nicolo, D.
    Panareo, M.
    Papa, A.
    Pepino, A.
    Raffaelli, F.
    Renga, F.
    Ripiccini, E.
    Signorelli, G.
    Tassielli, G. F.
    Valentini, R.
    Voena, C.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (12):
  • [37] The use of an ultra-thin instrument for difficult colonoscopy in unsedated patients
    Togashi, Kazutomo
    Nemoto, Daiki
    Isohata, Noriyuki
    Utano, Kenichi
    Endo, Shungo
    Hewett, David G.
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2012, 27 : 45 - 45
  • [38] ULTRA-THIN LIF-MG,CU,P DETECTORS FOR BETA-DOSIMETRY
    BILSKI, P
    OLKO, P
    BURGKHARDT, B
    PIESCH, E
    RADIATION MEASUREMENTS, 1995, 24 (04) : 439 - 443
  • [39] Development towards ultra-thin superconducting solenoid magnets for high energy particle detectors
    Yamamoto, A
    Makida, Y
    Tanaka, K
    Doi, Y
    Kondo, T
    Wada, K
    Meguro, S
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 1999, 78 : 565 - 570
  • [40] An ultra-thin diamond membrane as a transmission particle detector and vacuum window for external microbeams
    Grilj, V.
    Skukan, N.
    Pomorski, M.
    Kada, W.
    Iwamoto, N.
    Kamiya, T.
    Ohshima, T.
    Jaksic, M.
    APPLIED PHYSICS LETTERS, 2013, 103 (24)