COMPARATIVE EFFECTS OF CUFF SIZE AND TIGHTNESS OF FIT ON ACCURACY OF BLOOD-PRESSURE MEASUREMENTS

被引:8
|
作者
BANNER, TE [1 ]
GRAVENSTEIN, JS [1 ]
机构
[1] UNIV FLORIDA,J HILLIS MILLER HLTH CTR,DEPT ANESTHESIOL,BOX J-254,GAINESVILLE,FL 32610
来源
JOURNAL OF CLINICAL MONITORING | 1991年 / 7卷 / 04期
关键词
BLOOD PRESSURE; MEASUREMENT; EQUIPMENT; CUFFS; MEASUREMENT TECHNIQUES; MONITORING;
D O I
10.1007/BF01619345
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
To determine the effect of snugness of cuff wrap on the accuracy of blood pressure (BP) measurements, we performed two studies on 6 healthy volunteers. In both studies, control values were obtained from the right upper arm with cuffs of appropriate size and snug fit. Study 1 had two phases. In the first, cuffs of appropriate size were wrapped snugly around the upper left arm of seated subjects. The effects of two other degrees of cuff snugness on the measurement of BP were evaluated by placing a filled 250-mL intravenous fluid bag between the cuff and arm over the triceps, measuring BP, then draining the same bag of half its contents and then all of its contents without rewrapping the cuff ("loose," "very loose" fit), each time measuring BP. The second phase of study 1 was identical in procedure, except that the cuffs used on the left arm were one size too small. In study 2, the experimental cuffs were placed just above the right ankle. To alter the signal-to-noise ratio, BP was raised or lowered: the standing position elevated mean BP by an average of 90 mm Hg, and elevation of the legs decreased mean BP by an average of 43 mm Hg. In study 1, we found that appropriately sized cuffs, whether wrapped tightly or loosely, gave correct BP readings. Cuffs snugly wrapped, but too small for the subject, gave high BP readings, on the average by approximately 10 mm Hg. Loose wrapping of small cuffs gave variable results in individual subjects that exaggerated systolic BP from 2 to 80 mm Hg. In study 2, elevating the legs or standing decreased or increased BP consistently. Loose wrapping of appropriately sized cuffs around the ankles of the subjects had no additional significant effect on BP.
引用
收藏
页码:281 / 284
页数:4
相关论文
共 50 条
  • [41] CUFF PRESSURE OSCILLATIONS IN MEASUREMENT OF RELATIVE BLOOD-PRESSURE
    GEDDES, LA
    NEWBERG, DC
    PSYCHOPHYSIOLOGY, 1977, 14 (02) : 198 - 202
  • [42] DIFFERENCES IN BLOOD-PRESSURE LOWERING EFFECTS IN PGS FOLLOWING INDIRECT AND DIRECT BLOOD-PRESSURE MEASUREMENTS
    HEDLEY, LR
    VANANTWERP, DR
    STROSBERG, AM
    PROCEEDINGS OF THE WESTERN PHARMACOLOGY SOCIETY, 1984, 27 : 323 - 327
  • [43] Accuracy of cuff blood pressure and systolic blood pressure amplification
    Bui, Tan V.
    Picone, Dean S.
    Schultz, Martin G.
    Peng, Xiaoqing
    Black, J. Andrew
    Dwyer, Nathan
    Roberts-Thomson, Philip
    Adams, Heath
    Chen, Chen-Huan
    Cheng, Hao-min
    Pucci, Giacomo
    Wang, Jiguang
    Goupil, Remi
    Sharman, James E.
    HYPERTENSION RESEARCH, 2023, 46 (08) : 1961 - 1969
  • [44] ACCURACY OF CUFF BLOOD PRESSURE AND SYSTOLIC BLOOD PRESSURE AMPLIFICATION
    Bui, Tan
    Picone, Dean
    Schultz, Martin
    Peng, Xiaoqing
    Black, Andrew
    Dwyer, Nathan
    Thomson, Philip Roberts
    Adams, Heath
    Chen, Chen Huan
    Cheng, Hao Min
    Pucci, Giacomo
    Wang, Jiguang
    Goupil, Remi
    Sharman, James
    JOURNAL OF HYPERTENSION, 2023, 41 : E203 - E203
  • [45] ERRONEOUS BLOOD-PRESSURE MEASUREMENTS WITH A NONINVASIVE BLOOD-PRESSURE MONITOR
    EHLERS, KC
    GRABENBAUER, SA
    ANESTHESIOLOGY, 1991, 74 (05) : 967 - 967
  • [46] Accuracy of cuff blood pressure and systolic blood pressure amplification
    Tan V. Bui
    Dean S. Picone
    Martin G. Schultz
    Xiaoqing Peng
    J. Andrew Black
    Nathan Dwyer
    Philip Roberts-Thomson
    Heath Adams
    Chen-Huan Chen
    Hao-min Cheng
    Giacomo Pucci
    Jiguang Wang
    Remi Goupil
    James E. Sharman
    Hypertension Research, 2023, 46 : 1961 - 1969
  • [47] COMPARATIVE-ANALYSIS OF TONOMETRIC AND INTRAARTERIAL BLOOD-PRESSURE MEASUREMENTS
    KEMMOTSU, O
    MORIMOTO, Y
    OHTA, Y
    MAYUMI, T
    ANESTHESIOLOGY, 1994, 81 (3A) : A508 - A508
  • [48] Divergent effects of systolic blood pressure amplification on accuracy and precision of cuff blood pressure measurement
    Alberto Avolio
    Hypertension Research, 2023, 46 : 2240 - 2242
  • [49] Divergent effects of systolic blood pressure amplification on accuracy and precision of cuff blood pressure measurement
    Avolio, Alberto
    HYPERTENSION RESEARCH, 2023, 46 (09) : 2240 - 2242
  • [50] EVALUATION OF A NEW MULTISIZE BLOOD-PRESSURE CUFF
    BENNETT, JM
    VANDENBOGAERDE, E
    VANRENSBURG, JTJ
    SOUTH AFRICAN MEDICAL JOURNAL, 1987, 72 (09): : 610 - 611