摘要
One-unit fixed partial dentures, which fit accurately on the laboratory dies made from polysulfide impression materials, often pose a problem in seating completely in the mouth of the patient. Sectioning of the fixed partial denture units allows the individual units to seat accurately in the mouth but requires a soldering procedure. Linear distortion of the mercaptan (polysulfide) rubber base that takes place during setting is a cause of this problem. The distortion is directly related to (1) tray design, (2) area of adhesive placement, and (3) excessive bulk of material on the tray border during impression making. A controlled amount of adhesive and impression material in a new design for a custom tray must be used to minimize this distortion. When these factors are controlled, the resulting impression is unrestricted, and a more accurate working die is obtained. This results in a better fit of one-unit fixed partial dentures in the mouth. © 1990 The C. V. Mosby Company.
引用
收藏
页码:277 / 281
页数:5
相关论文
共 18 条
  • [1] EFFECT OF TRAY DESIGN ON HYDRAULIC FORCES DURING MAXILLARY IMPRESSIONS
    KENNAN, DEM
    JOURNAL OF DENTAL RESEARCH, 1978, 57 : 200 - 200
  • [2] LINEAR DIMENSIONAL CHANGES IN DENTAL IMPRESSIONS AFTER IMMERSION IN DISINFECTANT SOLUTIONS
    TULLNER, JB
    COMMETTE, JA
    MOON, PC
    JOURNAL OF PROSTHETIC DENTISTRY, 1988, 60 (06): : 725 - 728
  • [3] Effect of impression holding time and tray removal speed on the dimensional accuracy of impressions for artificial abutment tooth inclined
    Hirota, Yoshiaki
    Tawada, Yasuyuki
    Komatsu, Shigeki
    Watanabe, Fumihiko
    ODONTOLOGY, 2021, 109 (01) : 157 - 167
  • [4] Effect of impression holding time and tray removal speed on the dimensional accuracy of impressions for artificial abutment tooth inclined
    Yoshiaki Hirota
    Yasuyuki Tawada
    Shigeki Komatsu
    Fumihiko Watanabe
    Odontology, 2021, 109 : 157 - 167
  • [5] The effect of tray selection, viscosity of impression material, and sequence of pour on the accuracy of dies made from dual-arch impressions
    Ceyhan, JA
    Johnson, GH
    Lepe, X
    JOURNAL OF PROSTHETIC DENTISTRY, 2003, 90 (02): : 143 - 149
  • [6] Effect of immersion disinfection of alginate impressions in sodium hypochlorite solution on the dimensional changes of stone models
    Hiraguchi, Hisako
    Kaketani, Masahiro
    Hirose, Hideharu
    Yoneyama, Takayuki
    DENTAL MATERIALS JOURNAL, 2012, 31 (02) : 280 - 286
  • [7] The effect of tray selection, viscosity of impression material, and sequence of pour on the accuracy of dies made from dual-arch impressions (vol 90, pg 143, 2003)
    Ceyhan, J. A.
    Johnson, G. H.
    Lepe, X.
    JOURNAL OF PROSTHETIC DENTISTRY, 2007, 97 (01): : 38 - 38
  • [9] The Effect of abutment wall modification, filling material & copying design on retention of cement retained implant supported crown
    Aalaei, Shima
    Balaghi, Fatimah
    Gholami, Fatemeh
    INTERNATIONAL JOURNAL OF ADVANCED BIOTECHNOLOGY AND RESEARCH, 2016, 7 (04): : 2155 - 2161
  • [10] EFFECT OF IMPRESSION TRAY DESIGN AND IMPRESSION TECHNIQUE UPON THE ACCURACY OF STONE CASTS PRODUCED FROM A PUTTY-WASH POLYVINYL SILOXANE IMPRESSION MATERIAL
    SAUNDERS, WP
    SHARKEY, SW
    SMITH, GM
    TAYLOR, WG
    JOURNAL OF DENTISTRY, 1991, 19 (05) : 283 - 289