Comparisons of static 7 field and dynamic conformal arc techniques for stereotactic lung radiotherapy

被引:0
|
作者
Atalar, Banu [1 ]
Kucukmorkoc, Esra [1 ]
Doyuran, Mine [1 ]
Gungor, Gorkem [2 ]
Aydin, Gokhan [2 ]
Yapici, Bulent [2 ]
Caglar, Hale [1 ]
Ozyar, Enis [1 ]
机构
[1] Acibadem Univ, Radyasyon Onkolojisi, Istanbul, Turkey
[2] Acibadem Maslak Hastanesi, Radyasyon Onkolojisi, Istanbul, Turkey
来源
关键词
Lung cancer; radiotherapy; stereotactic radiotherapy;
D O I
10.5505/tjoncol.2012.843
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
OBJECTIVES We aimed to compare dynamic conformal arc (DCA) and static 7 field (S7F) techniques in terms of Radiation Therapy Oncology Group (RTOG) criteria for stereotactic lung radiotherapy. METHODS Treatment of 33 lung tumors was planned using DCA or S7F techniques, and tumors were allocated into groups according to their volume (small: <25 cc, medium: 25-50 cc, large: >50 cc) and localization (central, peripheral). Plans were compared in terms of lung volume receiving 5 Gy (V-5), spinal cord maxi- mum dose (spinal D-max) homogeneity index (HI), and monitor-unit (MU) parameters. RESULTS No statistical difference was shown in RTOG criteria. HI was lower with DCA (p=018) while V-5, spinal D-max and MU were lower with S7F (p=0.007, p=0.001, p<0.001, respectively). With the S7F technique, spinal D-max in small tumors, V-5, spinal D-max and MU in medium tumors, V-5 and MU in large tumors, V5 and spinal D-max in central tumors, and spinal D-max and MU in peripheral tumors were lower. CONCLUSION Spinal D-max, V-5 and MU were better with the S7F technique. Both techniques are appropriate for planning according to RTOG criteria.
引用
下载
收藏
页码:111 / 118
页数:8
相关论文
共 50 条
  • [21] Evaluation of the hybrid-dynamic conformal arc therapy technique for radiotherapy of lung cancer
    Kim, Sung Joon
    Lee, Jeong Won
    Kang, Min Kyu
    Kim, Jae-Chul
    Lee, Jeong Eun
    Park, Shin-Hyung
    Kim, Mi Young
    Lee, Seoung-Jun
    Moon, Soo-Ho
    Ko, Byoung-Soo
    RADIATION ONCOLOGY JOURNAL, 2018, 36 (03): : 241 - 247
  • [22] Assessment of treatment techniques and collimation in conformal stereotactic radiosurgery and radiotherapy
    Ahlswede, J
    Pfaender, M
    Grebe, G
    Böhmer, D
    Bohsung, J
    Groll, J
    Kaiser, A
    Schlenger, L
    Sommer, B
    Scheffler, D
    Stuschke, M
    Budach, V
    Wurm, R
    USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 206 - 206
  • [23] A comparison of robustness of volumetric modulated arc therapy and dynamic conformal arc therapy for lung stereotactic body radiation therapy
    Teague, Kathlina M.
    Miller, Daniel C.
    Nyamwanda, Jacqueline A.
    Prichard, Hugh A.
    Kirk, Michael C.
    MEDICAL DOSIMETRY, 2022, 47 (01) : 110 - 110
  • [24] RADIOLOGICAL AND CLINICAL PNEUMONITIS AFTER STEREOTACTIC LUNG RADIOTHERAPY: A MATCHED ANALYSIS OF THREE-DIMENSIONAL CONFORMAL AND VOLUMETRIC-MODULATED ARC THERAPY TECHNIQUES
    Palma, David A.
    Senan, Suresh
    Haasbeek, Cornelis J. A.
    Verbakel, Wilko F. A. R.
    Vincent, Andrew
    Lagerwaard, Frank
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (02): : 506 - 513
  • [25] The dosimetric effect of inhomogeneity correction in dynamic conformal arc stereotactic body radiation therapy for lung tumors
    Kavanagh, Brian
    Ding, Meisong
    Schefter, Tracey
    Stuhr, Kelly
    Newman, Francis
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2006, 7 (02): : 58 - 63
  • [26] Variable Dose-Rate Conformal Arc Planning for Stereotactic Body Radiotherapy
    Zhang, B.
    Lee, N.
    Chen, S.
    D'Souza, W.
    Prado, K.
    Yi, B.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [27] Dosimetric Evaluation of a Conformal Seven-field Coplanar Technique for Planning Lung Stereotactic Body Radiotherapy
    Richmond, N.
    Green, J.
    Peedell, C.
    Shakespeare, D.
    Walker, C.
    CLINICAL ONCOLOGY, 2012, 24 (01) : E24 - E30
  • [28] Dosimetry of conformal dynamic arc radiotherapy and intensity modulated radiotherapy in unresectable cholangiocarcinoma
    Peerawong, Thanarpan
    Khorprasert, Chonlakiet
    Suriyapee, Sivalee
    Sanghangthum, Taweap
    Ayuthaya, Isra Israngkul Na
    Shotelersuk, Kanjana
    ASIAN BIOMEDICINE, 2010, 4 (01) : 131 - 139
  • [29] STEREOTACTIC IMRT OF INTRACRANIAL LESIONS, A GOOD ALTERNATIVE FOR DYNAMIC CONFORMAL ARC?
    Bolt, R.
    Van der Schaaf, A.
    Bijl, H. P.
    Heesters, M.
    Langendijk, J.
    van 't Veld, A.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S464 - S464
  • [30] Dosimetric Evaluation of 3 Dimensional Conformal Radiotherapy (3DCRT), Dynamic Conformal Arc Therapy (DCAT) & Volumetric Arc Therapy (VMAT) in the Management of Non-Small Cell Lung Cancer (NSCLC) Using Stereotactic Body Radiotherapy (SBRT)
    Rauschenbach, B.
    Mackowiak, L.
    Malhotra, H.
    MEDICAL PHYSICS, 2013, 40 (06)