QUARTZ CRYSTAL RESONATOR-G SENSITIVITY MEASUREMENT METHODS AND RECENT RESULTS

被引:12
|
作者
DRISCOLL, MM
机构
[1] Westinghouse Electric Corporation, Electronics Systems Group, Baltimore, MD 21203, MS75
关键词
D O I
10.1109/58.105244
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A technique for accurate measurements of quartz crystal resonator vibration sensitivity. The technique utilizes a crystal oscillator circuit in which a prescribed length of coaxial cable is used to connect the resonator to the oscillator sustaining stage. A method is provided for determination and removal of measurement errors normally introduced as a result of cable vibration. In addition to oscillalor-type measurements, it is also possible to perform similar vibration sensitivity measurements using a synthesized signal generator with the resonator installed in a passive phase bridge. Test results are reported for 40 and 50 MHz, 5th overtone AT-cut and third overtone SC-cul crystals. Acceleration sensitivity (gamma vector) values for the SC-cul resonators were typically four times smaller (5 × 10−10 per g) than for the AT-cut units. However, smaller unit-to-unit gamma vector magnitude variation was exhibited by the AT-cut resonators. Oscillator sustaining stage vibration sensitivity was characterized by an equivalent open loop phase modulation of 10−6 rads per g. © 1990 IEEE
引用
收藏
页码:386 / 392
页数:7
相关论文
共 50 条
  • [31] Measurement of adsorption characteristics of alumina and activated carbon using a quartz crystal resonator with i-butane
    Byoung Chul Kim
    Takuji Yamamoto
    Yoon Sup Byun
    Young Han Kim
    Korean Journal of Chemical Engineering, 2010, 27 : 328 - 333
  • [32] Measurement of adsorption characteristics of alumina and activated carbon using a quartz crystal resonator with i-butane
    Kim, Byoung Chul
    Yamamoto, Takuji
    Byun, Yoon Sup
    Kim, Young Han
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2010, 27 (01) : 328 - 333
  • [33] LASER INTERFEROMETRIC MEASUREMENT OF VIBRATION DISPLACEMENTS OF A PLANO-CONVEX AT-CUT QUARTZ CRYSTAL RESONATOR
    IIJIMA, K
    TSUZUKI, Y
    HIROSE, Y
    AKIYAMA, M
    PROCEEDINGS OF THE IEEE, 1976, 64 (03) : 386 - 387
  • [34] Sensitive label-free immunoglobulin G detection using a MEMS quartz crystal microbalance biosensor with a 125 MHz wireless quartz resonator
    Zhou, Lianjie
    Kato, Fumihito
    Ogi, Hirotsugu
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2021, 60 (SD)
  • [35] COMPARISON OF TWO METHODS TO REDUCE TIME MEASUREMENT OF QUARTZ CRYSTAL MICROBALANCE GAS SENSORS
    Munoz-Mata, J. L.
    Osorio-Arrieta, D. L.
    Jimenez-Arellano, J. J.
    Beltran-Perez, G.
    Castillo-Mixcoatl, J.
    Munoz-Aguirre, S.
    2019 IEEE INTERNATIONAL SYMPOSIUM ON OLFACTION AND ELECTRONIC NOSE (ISOEN 2019), 2019, : 313 - 316
  • [36] A force measurement platform for a vitreoretinal surgical simulator using an artificial eye module integrated with a quartz crystal resonator
    Taniguchi, Yuta
    Sugiura, Hirotaka
    Yamanaka, Toshiro
    Watanabe, Shiro
    Omata, Seiji
    Harada, Kanako
    Mitsuishi, Mamoru
    Shiraya, Tomoyasu
    Sugimoto, Koichiro
    Ueta, Takashi
    Totsuka, Kiyohito
    Araki, Fumiyuki
    Takao, Muneyuki
    Aihara, Makoto
    Arai, Fumihito
    MICROSYSTEMS & NANOENGINEERING, 2022, 8 (01)
  • [37] A force measurement platform for a vitreoretinal surgical simulator using an artificial eye module integrated with a quartz crystal resonator
    Yuta Taniguchi
    Hirotaka Sugiura
    Toshiro Yamanaka
    Shiro Watanabe
    Seiji Omata
    Kanako Harada
    Mamoru Mitsuishi
    Tomoyasu Shiraya
    Koichiro Sugimoto
    Takashi Ueta
    Kiyohito Totsuka
    Fumiyuki Araki
    Muneyuki Takao
    Makoto Aihara
    Fumihito Arai
    Microsystems & Nanoengineering, 8
  • [38] A SIMPLE SINGLE MODEL FOR QUARTZ-CRYSTAL RESONATOR LOW-LEVEL DRIVE SENSITIVITY AND MONOLITHIC FILTER INTERMODULATION
    DWORSKY, L
    KINSMAN, RG
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1994, 41 (02) : 261 - 268
  • [39] Stiffness Measurement of Organoids Using a Wide-Range Force Sensor Probe Fabricated Using a Quartz Crystal Resonator
    Watanabe, Shiro
    Sugiura, Hirotaka
    Arai, Fumihito
    IEEE ROBOTICS AND AUTOMATION LETTERS, 2022, 7 (02): : 2535 - 2540
  • [40] Wide-range Load Sensor Using Vacuum Sealed Quartz Crystal Resonator for Simultaneous Biosignals Measurement on Bed
    Murozaki, Yuichi
    Arai, Fumihito
    2020 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2020, : 1015 - 1020