Accuracy and reliability of stitched cone-beam computed tomography images

被引:13
|
作者
Egbert, Nicholas [1 ]
Cagna, David R. [2 ]
Ahuja, Swati [2 ]
Wicks, Russell A. [2 ]
机构
[1] Reconstruct Dent Specialists Utah, Salt Lake City, UT USA
[2] Univ Tennessee, Hlth Sci Ctr, Coll Dent, Dept Prosthodont, Memphis, TN 38163 USA
关键词
Cone-Beam Computed Tomography; Computer-Aided Design; Dental Implants;
D O I
10.5624/isd.2015.45.1.41
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study was performed to evaluate the linear distance accuracy and reliability of stitched small field of view (FOV) cone-beam computed tomography (CBCT) reconstructed images for the fabrication of implant surgical guides. Material and Methods: Three gutta percha points were fixed on the inferior border of a cadaveric mandible to serve as control reference points. Ten additional gutta percha points, representing fiduciary markers, were scattered on the buccal and lingual cortices at the level of the proposed complete denture flange. A digital caliper was used to measure the distance between the reference points and fiduciary markers, which represented the anatomic linear dimension. The mandible was scanned using small FOV CBCT, and the images were then reconstructed and stitched using the manufacturer's imaging software. The same measurements were then taken with the CBCT software. Results: The anatomic linear dimension measurements and stitched small FOV CBCT measurements were statistically evaluated for linear accuracy. The mean difference between the anatomic linear dimension measurements and the stitched small FOV CBCT measurements was found to be 0.34 mm with a 95% confidence interval of +0.24 - +0.44 mm and a mean standard deviation of 0.30 mm. The difference between the control and the stitched small FOV CBCT measurements was insignificant within the parameters defined by this study. Conclusion: The proven accuracy of stitched small FOV CBCT data sets may allow image-guided fabrication of implant surgical stents from such data sets.
引用
收藏
页码:41 / 47
页数:7
相关论文
共 50 条
  • [21] ACCURACY AND DOSE OF A CONE-BEAM COMPUTED TOMOGRAPHY FOR STEREOTACTIC RADIOSURGERY SETUP
    Sancho, I.
    Modolell, I.
    Ferrer, F.
    Lizuain, M. C.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S422 - S422
  • [22] Method of visualisation influences accuracy of measurements in cone-beam computed tomography
    Patcas, Raphael
    Angst, Christine
    Kellenberger, Christian J.
    Schaetzle, Marc A.
    Ullrich, Oliver
    Markic, Goran
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2015, 43 (07) : 1277 - 1283
  • [23] Accuracy of cone-beam computed tomography in predicting the diameter of unerupted teeth
    Nguyen, Emerald
    Boychuk, Darrell
    Orellana, Maria
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 140 (02) : e59 - e66
  • [24] Accuracy and feasibility of cone-beam computed tomography for stereotactic radiosurgery setup
    Chang, Jenghwa
    Yenice, Kamil M.
    Narayana, Ashwatha
    Gutin, Philip H.
    MEDICAL PHYSICS, 2007, 34 (06) : 2077 - 2084
  • [25] Diagnostic Accuracy of Cone-Beam Computed Tomography in the Evaluation of Chronic Rhinosinusitis
    Zojaji, Ramin
    Naghibzadeh, Masoud
    Baf, Morteza Mazloum Farsi
    Nekooei, Sirous
    Bataghva, Behrokh
    Noorbakhsh, Sara
    ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY HEAD AND NECK SURGERY, 2015, 77 (01): : 55 - 60
  • [26] The reliability of cone-beam computed tomography (CBCT) - Generated frontal cephalogramsq
    Kim, So-Jin
    Park, Soo-Byung
    Kim, Yong-Il
    Cho, Bong-Hae
    Hwang, Dae-Seok
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2012, 40 (08) : E331 - E336
  • [27] Accuracy and reliability of buccal bone height and thickness measurements from cone-beam computed tomography imaging
    Timock, Adam M.
    Cook, Valane
    McDonald, Terry
    Leo, Michael C.
    Crowe, Jennifer
    Benninger, Brion L.
    Covell, David A., Jr.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 140 (05) : 734 - 744
  • [28] Evaluation of the Reliability and Accuracy of Using Cone-beam Computed Tomography for Diagnosing Periapical Cysts from Granulomas
    Guo, Jing
    Simon, James H.
    Sedghizadeh, Parish
    Soliman, Osman N.
    Chapman, Travis
    Enciso, Reyes
    JOURNAL OF ENDODONTICS, 2013, 39 (12) : 1485 - 1490
  • [29] Finding Dense Supervoxel Correspondence of Cone-Beam Computed Tomography Images
    Pei, Yuru
    Yi, Yunai
    Ma, Gengyu
    Guo, Yuke
    Chen, Gui
    Xu, Tianmin
    Zha, Hongbin
    MACHINE LEARNING IN MEDICAL IMAGING (MLMI 2017), 2017, 10541 : 114 - 122
  • [30] Anatomical evaluation of the craniovertebral junction on cone-beam computed tomography images
    Tanrisever, Sefkan
    Orhan, Mustafa
    Bahsi, Ilhan
    Yalcin, Eda Didem
    SURGICAL AND RADIOLOGIC ANATOMY, 2020, 42 (07) : 797 - 815