Accuracy and reliability of stitched cone-beam computed tomography images

被引:13
|
作者
Egbert, Nicholas [1 ]
Cagna, David R. [2 ]
Ahuja, Swati [2 ]
Wicks, Russell A. [2 ]
机构
[1] Reconstruct Dent Specialists Utah, Salt Lake City, UT USA
[2] Univ Tennessee, Hlth Sci Ctr, Coll Dent, Dept Prosthodont, Memphis, TN 38163 USA
关键词
Cone-Beam Computed Tomography; Computer-Aided Design; Dental Implants;
D O I
10.5624/isd.2015.45.1.41
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study was performed to evaluate the linear distance accuracy and reliability of stitched small field of view (FOV) cone-beam computed tomography (CBCT) reconstructed images for the fabrication of implant surgical guides. Material and Methods: Three gutta percha points were fixed on the inferior border of a cadaveric mandible to serve as control reference points. Ten additional gutta percha points, representing fiduciary markers, were scattered on the buccal and lingual cortices at the level of the proposed complete denture flange. A digital caliper was used to measure the distance between the reference points and fiduciary markers, which represented the anatomic linear dimension. The mandible was scanned using small FOV CBCT, and the images were then reconstructed and stitched using the manufacturer's imaging software. The same measurements were then taken with the CBCT software. Results: The anatomic linear dimension measurements and stitched small FOV CBCT measurements were statistically evaluated for linear accuracy. The mean difference between the anatomic linear dimension measurements and the stitched small FOV CBCT measurements was found to be 0.34 mm with a 95% confidence interval of +0.24 - +0.44 mm and a mean standard deviation of 0.30 mm. The difference between the control and the stitched small FOV CBCT measurements was insignificant within the parameters defined by this study. Conclusion: The proven accuracy of stitched small FOV CBCT data sets may allow image-guided fabrication of implant surgical stents from such data sets.
引用
收藏
页码:41 / 47
页数:7
相关论文
共 50 条
  • [1] Expression of beam hardening artifacts on horizontally stitched cone-beam computed tomography images
    da Fonte, Juliana B. Melo
    Fontenele, Rocharles Cavalcante
    Freitas, Deborah Queiroz
    IMAGING SCIENCE IN DENTISTRY, 2024,
  • [2] Reliability and accuracy of cone-beam computed tomography dental measurements
    Baumgaertel, Sebastian
    Palomo, J. Martin
    Palomo, Leena
    Hans, Mark G.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (01) : 19 - 25
  • [3] Zygomaticofacial foramen location accuracy and reliability in cone-beam computed tomography
    del Neri, Nathalia Bigelli
    Araujo-Pires, Ana Claudia
    Andreo, Jesus Carlos
    Fisher Rubira-Bullen, Izabel Regina
    Ferreira Junior, Osny
    ACTA ODONTOLOGICA SCANDINAVICA, 2014, 72 (02) : 157 - 160
  • [4] Automated landmark identification on cone-beam computed tomography: Accuracy and reliability
    Ghowsi, Ali
    Hatcher, David
    Suh, Heeyeon
    Wile, David
    Castro, Wesley
    Krueger, Jan
    Park, Joorok
    Oh, Heesoo
    ANGLE ORTHODONTIST, 2022, 92 (05) : 642 - 654
  • [5] Accuracy and reliability of cone-beam computed tomography for airway volume analysis
    Ghoneima, Ahmed
    Kula, Katherine
    EUROPEAN JOURNAL OF ORTHODONTICS, 2013, 35 (02) : 256 - 261
  • [7] Accuracy of reconstructed images from cone-beam computed tomography scans
    Lamichane, Manish
    Anderson, Nina Kay
    Rigali, Paul H.
    Seldin, Edward B.
    Will, Leslie A.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (02) : 156.e1 - 156.e6
  • [8] Accuracy and reliability of cone-beam computed tomography measurements: Influence of head orientation
    El-Beialy, Amr Ragab
    Fayed, Mona Salah
    El-Bialy, Ahmed Mohammed
    Mostafa, Yehya A.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 140 (02) : 157 - 165
  • [9] Finger fractures imaging: accuracy of cone-beam computed tomography and multislice computed tomography
    Faccioli, Niccolo
    Foti, Giovanni
    Barillari, Marco
    Atzei, Andrea
    Mucelli, Roberto Pozzi
    SKELETAL RADIOLOGY, 2010, 39 (11) : 1087 - 1095
  • [10] Finger fractures imaging: accuracy of cone-beam computed tomography and multislice computed tomography
    Niccolò Faccioli
    Giovanni Foti
    Marco Barillari
    Andrea Atzei
    Roberto Pozzi Mucelli
    Skeletal Radiology, 2010, 39 : 1087 - 1095