APPLICATION OF A GE DETECTOR TO SEARCH FOR FAST-NEUTRONS FROM DD FUSION IN DEUTERIZED PD

被引:1
|
作者
CHOI, E
EJIRI, H
OHSUMI, H
机构
[1] Department of Physics, Osaka University, Toyonaka
关键词
COLD NUCLEAR FUSION; LOW-BACKGROUND NEUTRON DETECTOR;
D O I
10.1143/JJAP.32.3964
中图分类号
O59 [应用物理学];
学科分类号
摘要
A low-background high-resolution Ge detector surrounded by neutron scatterers was applied to investigate fast neutrons from the electrochemically loaded Pd-D system. The neutron flux was obtained by measuring the yields of the gamma-rays following inelastic scattering of the fast neutrons from nuclei in the scatterers. The detector was shown to be very sensitive in the search for rare neutron events such as d-d fusion at room temperature. The observed spectrum shows no statistically significant excess of the gamma-rays above the background. The upper limit on the fusion rate was obtained as lambda(f)<1.6.10(-24)(ddn)fusions/(dd)pair/s.
引用
下载
收藏
页码:3964 / 3967
页数:4
相关论文
共 50 条
  • [21] PRELIMINARY-RESULTS ON THE FEASIBILITY OF A LIQUID METHANE DETECTOR FOR FAST-NEUTRONS
    BRESSI, G
    CAMBIAGHI, M
    CARUGNO, G
    CENTRO, S
    CONTI, E
    DAINESE, B
    PRETE, G
    TONIOLO, N
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 300 (02): : 321 - 327
  • [22] SPECTRA OF FAST-NEUTRONS FROM A PULSED REACTOR
    DOROSHENKO, GG
    KRAITOR, SN
    KUZNETSOVA, TV
    KUSHNEREVA, KK
    LEONOV, ES
    FROLOVA, GA
    SOVIET ATOMIC ENERGY, 1976, 40 (06): : 550 - 554
  • [23] FAST-NEUTRONS IN RADIOTHERAPY AS SEEN FROM EDINBURGH
    WILLIAMS, JR
    PHYSICS IN MEDICINE AND BIOLOGY, 1982, 27 (01): : 163 - 163
  • [24] OVERVIEW AND PROSPECTS OF THE APPLICATION OF FAST-NEUTRONS IN CANCER-THERAPY
    WAMBERSIE, A
    BARENDSEN, GW
    BRETEAU, N
    JOURNAL EUROPEEN DE RADIOTHERAPIE, 1984, 5 (03): : 248 - 264
  • [25] SPECTROMETERS FOR FAST-NEUTRONS FROM SOLAR-FLARES
    SLOBODRIAN, RJ
    POTVIN, L
    RIOUX, C
    LIFE SCIENCES AND SPACE RESEARCH XXV(2): RADIATION BIOLOGY, 1994, 14 (10): : 725 - 730
  • [26] BD-9 INTEGRAL DISCRIMINATOR IN SCINTILLATION DETECTOR SCHEME OF FAST-NEUTRONS
    IVANOV, EA
    USATYUK, VV
    PRIBORY I TEKHNIKA EKSPERIMENTA, 1973, (01): : 105 - 106
  • [27] SPARK COUNTING OF TRACKS DIRECTLY INDUCED BY FAST-NEUTRONS IN CELLULOSE NITRATE DETECTOR
    SAWAMURA, T
    NOMURA, M
    YAMAZAKI, H
    OZAWA, Y
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1981, 18 (10) : 766 - 772
  • [29] DOSIMETRIC STUDIES WITH FAST-NEUTRONS FROM A MEDICAL CYCLOTRON
    KAWACHI, K
    KUCHNIR, FT
    SKAGGS, LS
    PHYSICS IN MEDICINE AND BIOLOGY, 1974, 19 (02): : 234 - 234
  • [30] INELASTIC-SCATTERING OF FAST-NEUTRONS FROM IRON
    SALAMA, M
    ATOMKERNENERGIE-KERNTECHNIK, 1981, 37 (03): : 221 - 222