MICRODOSIMETRY FOR BORON NEUTRON-CAPTURE THERAPY

被引:46
|
作者
WUU, CS
AMOLS, HI
KLIAUGA, P
REINSTEIN, LE
SARAF, S
机构
[1] COLUMBIA UNIV,CTR RADIOL RES,NEW YORK,NY 10032
[2] SUNY STONY BROOK,DEPT RADIAT ONCOL,STONY BROOK,NY 11794
[3] BROOKHAVEN NATL LAB,UPTON,NY 11973
关键词
D O I
10.2307/3578381
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Preclinical studies for boron neutron capture therapy (BNCT) using epithermal neutrons are ongoing at several laboratories. The absorbed dose in tumor cells is a function of the thermal neutron flux at depth, the microscopic boron concentration, and the size of the cell. Dosimetry is therefore complicated by the admixture of thermal, epithermal, and fast neutrons, plus γ rays, and the array of secondary high-linear-energy- transfer particles produced within the patient from neutron interactions. Microdosimetry can be a viable technique for determining absorbed dose and radiation quality. A 2.5-cm-diameter tissue-equivalent gas proportional counter has been built with 50 parts per million (ppm) 10B incorporated into the walls and counting gas to simulate the boron uptake anticipated in tumors. Measurements of lineal energy (y) spectra for BNCT in simulated volumes of 1-10 μm diameter show a dose enhancement factor of 4.3 for 30 ppm boron, and a 'y' of 250 keV/μm for the boron capture process. Chamber design plus details of experimental and calculated lineal energy spectra will be presented.
引用
收藏
页码:355 / 359
页数:5
相关论文
共 50 条
  • [21] DOSE PRESCRIPTION IN BORON NEUTRON-CAPTURE THERAPY
    GUPTA, N
    GAHBAUER, RA
    BLUE, TE
    WAMBERSIE, A
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (05): : 1157 - 1166
  • [22] Macro- and microdosimetry for boron neutron capture therapy with a MOSFET
    Rosenfeld, AB
    Kaplan, GI
    Carolan, MG
    Allen, BJ
    Kota, C
    Yudelev, M
    Maughan, R
    Coderre, JA
    [J]. ADVANCES IN NEUTRON CAPTURE THERAPY, VOLS I AND II: VOL I: MEDICINE AND PHYSICS, VOL II: CHEMISTRY AND BIOLOGY, 1997, 1132 : A198 - A204
  • [23] Performance of silicon microdosimetry detectors in boron neutron capture therapy
    Bradley, PD
    Rosenfeld, AB
    Allen, B
    Coderre, J
    Capala, J
    [J]. RADIATION RESEARCH, 1999, 151 (03) : 235 - 243
  • [24] An innovative approach for microdosimetry analysis in boron neutron capture therapy
    Lu, XQ
    Kiger, WS
    [J]. RESEARCH AND DEVELOPMENT IN NEUTRON CAPTURE THERAPY, 2002, : 605 - 608
  • [25] A PROTOTYPE EPITHERMAL NEUTRON BEAM FOR BORON NEUTRON-CAPTURE THERAPY
    NOONAN, DJ
    RUSSELL, JL
    BRUGGER, RM
    [J]. MEDICAL PHYSICS, 1986, 13 (02) : 211 - 216
  • [26] Microdosimetry of an accelerator based thermal neutron field for Boron Neutron Capture Therapy
    Selva, A.
    Bellan, L.
    Bianchi, A.
    Giustiniani, G.
    Colautti, P.
    Fagotti, E.
    Pisent, A.
    Conte, V.
    [J]. APPLIED RADIATION AND ISOTOPES, 2022, 182
  • [27] BORON NEUTRON-CAPTURE RADIOGRAPHY - PERSPECTIVES IN MELANOMA THERAPY
    LARSSON, BS
    [J]. UPSALA JOURNAL OF MEDICAL SCIENCES, 1986, 91 (03) : 263 - 268
  • [28] Microdosimetry of neutron field for boron neutron capture therapy at Kyoto University Reactor
    Endo, S
    Onizuka, Y
    Ishikawa, M
    Takada, M
    Sakurai, Y
    Kobayashi, T
    Tanaka, K
    Hoshi, M
    Shizuma, K
    [J]. RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) : 641 - 644
  • [29] PRESENT STATUS AND PERSPECTIVES OF BORON NEUTRON-CAPTURE THERAPY
    GABEL, D
    [J]. RADIOTHERAPY AND ONCOLOGY, 1994, 30 (03) : 199 - 205
  • [30] BORON NEUTRON-CAPTURE THERAPY IN MALIGNANT-MELANOMA
    CHARTIER, C
    KOESSLER, A
    ABBE, JC
    SAHEL, J
    [J]. ANNALES DE DERMATOLOGIE ET DE VENEREOLOGIE, 1993, 120 (09): : 631 - 634