Reliability of a measurement method for the cross-sectional area of the longus colli using real-time ultrasound imaging

被引:4
|
作者
O'Riordan, Cliona [1 ]
Van De Ven, Pepijn [2 ]
Nelson, John [2 ]
McCreesh, Karen [1 ]
Clifford, Amanda [1 ]
机构
[1] Univ Limerick, Dept Clin Therapies, Hlth Sci Bldg,2nd Floor, Limerick, Ireland
[2] Univ Limerick, Dept Sci & Engn, Limerick, Ireland
关键词
Real-time; ultrasound; longus colli; reliability;
D O I
10.1177/1742271X16659099
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective Real-time ultrasound imaging is an established objective outcome measurement with proven reliability. However, it is still largely biased by user-ability. Published research in the area of real-time ultrasound imaging reliability in the cervical region and in particular the deep cervical flexors is quite sparse. The purpose of this investigation was to examine if a novice ultrasound user could agree favourably with an experienced ultrasound sonographer in measuring the cross-sectional area of the longus colli. Methods Ultrasound images were captured from 22 healthy subjects on two different occasions, one week apart, by a novice ultrasound user. They were acquired using a GE Healthcare LOGIQe ultrasound machine, at a depth of 3-4cm with the transducer frequency set to 8MHz, in line with previous research guidelines. Cross-sectional area was then measured on-screen by both a novice and experienced ultrasound user to determine inter-rater reliability. Intra-rater reliability was also analysed using cross-sectional area figures from days one and two. Results Intra-rater reliability for real-time ultrasound imaging for the cross-sectional area of the longus colli was excellent (intra-class correlation 0.90, 95% CI 0.82-0.95). Inter-rater reliability was moderate but in keeping with previous published research (intra-class correlation 0.61, 95% CI 0.37-0.77). Conclusion Difficulties in identifying the borders of the longus colli muscle due to its deep anatomical location and surrounding structures make it difficult for assessors to agree favourably on cross-sectional area measurements, leading to moderate levels of inter-rater reliability and poor agreement. Intra-rater reliability is excellent, and in this instance indicates that a novice user can be just as reliable as a more experienced ultrasound user.
引用
收藏
页码:154 / 162
页数:9
相关论文
共 50 条
  • [31] Cervical Multifidus and Longus Colli Ultrasound Differences among Patients with Cervical Disc Bulging, Protrusion and Extrusion and Asymptomatic Controls: A Cross-Sectional Study
    Javanshir, Khodabakhsh
    Ghafouri-Rouzbehani, Payam
    Zohrehvand, Amirhossein
    Naeimi, Arvin
    Fernandez-de-las-Penas, Cesar
    Nikbakht, Hossein-Ali
    Mousavi-Khatir, Seyedeh Roghayeh
    Valera-Calero, Juan Antonio
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (02)
  • [32] Real-time Burn Classification using Ultrasound Imaging
    Lee, Sangrock
    Rahul
    Ye, Hanglin
    Chittajallu, Deepak
    Kruger, Uwe
    Boyko, Tatiana
    Lukan, James K.
    Enquobahrie, Andinet
    Norfleet, Jack
    De, Suvranu
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [33] Real-time Burn Classification using Ultrasound Imaging
    Sangrock Lee
    Hanglin Rahul
    Deepak Ye
    Uwe Chittajallu
    Tatiana Kruger
    James K. Boyko
    Andinet Lukan
    Jack Enquobahrie
    Suvranu Norfleet
    Scientific Reports, 10
  • [34] REAL-TIME CROSS-SECTIONAL ECHOCARDIOGRAPHY - APPLICATION IN THE MEASUREMENT OF THE SURFACE-AREA OF THE MITRAL ORIFICE IN CASES OF STENOSIS OR OF DOUBLE INVOLVEMENT OF THE VALVE
    BAREISS, P
    WARTER, J
    KIENY, R
    CLASS, JJ
    EISENMANN, B
    CHARBEL, P
    HEITZ, A
    HUCK, F
    PASQUALI, JL
    NOUVELLE PRESSE MEDICALE, 1979, 8 (41): : 3329 - 3333
  • [35] The cross-sectional area ratio of a specific part of the flexor pollicis longus tendon- a stable sonographic measurement for trigger thumb: a cross-sectional trial
    Zhu, Wenbin
    Zhou, Huan
    Hu, Zhe
    Chen, Hongyan
    Liu, Juan
    Li, Jin
    Feng, Xiaoyuan
    Li, Xueqin
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [36] The cross-sectional area ratio of a specific part of the flexor pollicis longus tendon- a stable sonographic measurement for trigger thumb: a cross-sectional trial
    Wenbin Zhu
    Huan Zhou
    Zhe Hu
    Hongyan Chen
    Juan Liu
    Jin Li
    Xiaoyuan Feng
    Xueqin Li
    BMC Musculoskeletal Disorders, 24
  • [37] Reliability And Validity Of Ultrasound Cross-sectional Area Measurements For Long-duration Spaceflight
    Scott, Jessica M.
    Martin, David S.
    Cunningham, David
    Matz, Timothy
    Caine, Timothy
    Hackney, Kyle J.
    Arzeno, Natalia M.
    Ploutz-Snyder, Lori
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2011, 43 (05): : 823 - 824
  • [38] Serial measurement of cross-sectional area in peripheral vein grafts using three-dimensional ultrasound
    Leotta, DF
    Primozich, JF
    Beach, KW
    Bergelin, RO
    Strandness, DE
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (01): : 61 - 68
  • [39] Conductance method for time measurement of cross-sectional areas of the aorta
    Kornet, L
    Jansen, JRC
    Gussenhoven, EJ
    Hardeman, MR
    Hoeks, APG
    Versprille, A
    ANNALS OF BIOMEDICAL ENGINEERING, 1999, 27 (02) : 141 - 150
  • [40] A SIMPLE METHOD OF MEASUREMENT OF GALLBLADDER VOLUME BY REAL-TIME ULTRASOUND
    KESHAVARZIAN, A
    DUNNE, M
    CASEY, J
    IBER, FL
    HEPATOLOGY, 1985, 5 (05) : 1003 - 1003