Reliability of a measurement method for the cross-sectional area of the longus colli using real-time ultrasound imaging

被引:4
|
作者
O'Riordan, Cliona [1 ]
Van De Ven, Pepijn [2 ]
Nelson, John [2 ]
McCreesh, Karen [1 ]
Clifford, Amanda [1 ]
机构
[1] Univ Limerick, Dept Clin Therapies, Hlth Sci Bldg,2nd Floor, Limerick, Ireland
[2] Univ Limerick, Dept Sci & Engn, Limerick, Ireland
关键词
Real-time; ultrasound; longus colli; reliability;
D O I
10.1177/1742271X16659099
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective Real-time ultrasound imaging is an established objective outcome measurement with proven reliability. However, it is still largely biased by user-ability. Published research in the area of real-time ultrasound imaging reliability in the cervical region and in particular the deep cervical flexors is quite sparse. The purpose of this investigation was to examine if a novice ultrasound user could agree favourably with an experienced ultrasound sonographer in measuring the cross-sectional area of the longus colli. Methods Ultrasound images were captured from 22 healthy subjects on two different occasions, one week apart, by a novice ultrasound user. They were acquired using a GE Healthcare LOGIQe ultrasound machine, at a depth of 3-4cm with the transducer frequency set to 8MHz, in line with previous research guidelines. Cross-sectional area was then measured on-screen by both a novice and experienced ultrasound user to determine inter-rater reliability. Intra-rater reliability was also analysed using cross-sectional area figures from days one and two. Results Intra-rater reliability for real-time ultrasound imaging for the cross-sectional area of the longus colli was excellent (intra-class correlation 0.90, 95% CI 0.82-0.95). Inter-rater reliability was moderate but in keeping with previous published research (intra-class correlation 0.61, 95% CI 0.37-0.77). Conclusion Difficulties in identifying the borders of the longus colli muscle due to its deep anatomical location and surrounding structures make it difficult for assessors to agree favourably on cross-sectional area measurements, leading to moderate levels of inter-rater reliability and poor agreement. Intra-rater reliability is excellent, and in this instance indicates that a novice user can be just as reliable as a more experienced ultrasound user.
引用
收藏
页码:154 / 162
页数:9
相关论文
共 50 条
  • [1] AN INVIVO AREA METER FOR REAL-TIME MEASUREMENT OF CROSS-SECTIONAL AREA IN THE CARDIOVASCULAR-SYSTEM
    TAMIYA, K
    HIGASHIDATE, M
    BEPPU, T
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1991, 12 (03): : 253 - 260
  • [2] Cross-sectional area of the longus colli and cervical degenerative spondylolisthesis: A retrospective review evaluating this anatomic consideration
    Tran, Khoa S.
    Mazmudar, Aditya
    Paziuk, Taylor
    Lambrechts, Mark J.
    Tecce, Eric
    Blaber, Olivia
    Habbal, Daniel
    Okroj, Kamil
    Karamian, Brian A.
    Canseco, Jose A.
    Rihn, Jeffrey
    Hilibrand, Alan
    Kepler, Christopher K.
    Vaccaro, Alexander R.
    Schroeder, Gregory D.
    JOURNAL OF CRANIOVERTEBRAL JUNCTION AND SPINE, 2022, 13 (04): : 421 - 426
  • [3] Reliability and Comparison of Measurements of the Tibialis Posterior Cross-Sectional Area Via Ultrasound Imaging
    Violette, Victoria A.
    Ridge, Sarah T.
    Bruening, Dustin
    Myrer, J. W.
    Johnson, A. W.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2017, 49 (05): : 768 - 768
  • [4] NONINVASIVE DIRECT IMAGING AND MEASUREMENT OF PATENT DUCTUS-ARTERIOSUS (PDA) USING REAL-TIME CROSS-SECTIONAL ECHOCARDIOGRAPHY
    SAHN, DJ
    SOBOL, RG
    ALLEN, HD
    CIRCULATION, 1977, 56 (04) : 191 - 191
  • [5] Comparison of the Cross-Sectional Area of Longus Colli Muscle Between Patients With Cervical Radicular Pain and Healthy Controls
    Noormohammadpour, Pardis
    Dehghani-Firouzabadi, Azime
    Mansournia, Mohammad Ali
    Mohseni-Bandpei, Mohammad Ali
    Moghaddam, Navid
    Miri, Mojtaba
    Kordi, Ramin
    PM&R, 2017, 9 (02) : 120 - 126
  • [6] FETAL THORACIC CIRCUMFERENCE - A PROSPECTIVE CROSS-SECTIONAL STUDY WITH REAL-TIME ULTRASOUND
    FONG, K
    OHLSSON, A
    ZALEV, A
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1988, 158 (05) : 1154 - 1160
  • [7] REAL-TIME CROSS-SECTIONAL ECHOCARDIOGRAPHIC IMAGING AND MEASUREMENT OF PATENT DUCTUS-ARTERIOSUS IN INFANTS AND CHILDREN
    SAHN, DJ
    ALLEN, HD
    CIRCULATION, 1978, 58 (02) : 343 - 354
  • [8] PLOTTING THE CROSS-SECTIONAL AREA OF THE INTERNAL CAROTID-ARTERY IN REAL-TIME
    MILES, RD
    SIEVERS, BE
    RUSSELL, JB
    SUMNER, DS
    STROKE, 1982, 13 (01) : 121 - 121
  • [9] The Reliability of Rehabilitative Ultrasound Imaging of the Cross-sectional Area of the Lumbar Multifidus Muscles in the PNF Pattern
    Huang, Qiuchen
    Li, Desheng
    Zhang, Yuying
    Hu, Anming
    Huo, Ming
    Maruyama, Hitoshi
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2014, 26 (10) : 1539 - 1541
  • [10] REAL-TIME CROSS-SECTIONAL ECHOCARDIOGRAPHY USING A MECHANICAL SECTOR SCANNER
    BAREISS, P
    CLASS, JJ
    PASQUALI, JL
    MEYER, R
    STORCK, D
    WARTER, J
    NOUVELLE PRESSE MEDICALE, 1978, 7 (43): : 3901 - 3904