Point of Care Quantitative Assessment of Muscle Health in Older Individuals: An Investigation of Quantitative Muscle Ultrasound and Electrical Impedance Myography Techniques

被引:14
|
作者
Hobson-Webb, Lisa D. [1 ]
Zwelling, Paul J. [1 ]
Pifer, Ashley N. [1 ]
Killelea, Carrie M. [2 ,3 ]
Faherty, Mallory S. [2 ,3 ]
Sell, Timothy C. [2 ,3 ]
Pastva, Amy M. [2 ,4 ]
机构
[1] Duke Univ, Dept Neurol, Neuromuscular Div, Durham, NC 27710 USA
[2] Duke Univ, Dept Orthopaed Surg, Durham, NC 27710 USA
[3] Michael W Krzyzewski Human Performance Lab, Durham, NC 27710 USA
[4] Duke Univ, Claude D Pepper Older Amer Independence Ctr, Durham, NC 27710 USA
关键词
elderly; aging; muscle; ultrasound; electrical impedance myography; point of care; TUG; frailty;
D O I
10.3390/geriatrics3040092
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
Background: Muscle health is recognized for its critical role in the functionality and well-being of older adults. Readily accessible, reliable, and inexpensive methods of measuring muscle health are needed to advance research and clinical care. Methods: In this prospective, blinded study, 27 patients underwent quantitative muscle ultrasound (QMUS), standard electrical impedance myography (sEIM), and handheld electrical impedance myography (hEIM) of the anterior thigh musculature by two independent examiners. Subjects also had dual-energy X-ray absorptiometry (DEXA) scans and standardized tests of physical function and strength. Data were analyzed for intra- and inter-rater reliability, along with correlations with DEXA and physical measures. Results: Measures of intra- and inter-rater reliability were excellent (>0.90) for all QMUS, sEIM, and hEIM parameters except intra- rater reliability of rectus femoris echointensity (0.87-0.89). There were moderate, inverse correlations between QMUS, sEIM, and hEIM parameters and measures of knee extensor strength. Moderate to strong correlations (0.57-0.81) were noted between investigational measures and DEXA-measured fat mass. Conclusions: QMUS, sEIM and hEIM were highly reliable in a controlled, same-day testing protocol. Multiple correlations with measures of strength and body composition were noted for each method. Point-of-care technologies may provide an alternative means of measuring health.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Quantitative assessment of muscle properties in polymyositis and dermatomyositis using high-frequency ultrasound and shear wave elastography
    Li, Min
    Guo, Ruiqian
    Tang, Xinyi
    Huang, Songya
    Qiu, Li
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (01) : 428 - +
  • [42] Delayed-Onset Muscle Soreness: Temporal Assessment With Quantitative MRI and Shear-Wave Ultrasound Elastography
    Agten, Christoph A.
    Buck, Florian M.
    Dyer, Linda
    Fluck, Martin
    Pfirrmann, Christian W. A.
    Rosskopf, Andrea B.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 208 (02) : 402 - 412
  • [43] Quantitative Liver Fat Assessment by Handheld Point-of-Care Ultrasound: A Technical Implementation and Pilot Study in Adults
    Tamayo-Murillo, Dorathy
    Weeks, Jake T.
    Keller, Cody A.
    Andre, Michael
    Gonzalez, Celene
    Li, Andrew
    Grunvald, Eduardo
    Liau, Joy
    Shabanan, Sedighe Hosseini
    Wolfson, Tanya
    Zuo, Jingyi
    Robinson, Adam
    Carrascal, Carolina Amador
    Sanchez, Nevada
    Reeder, Scott B.
    Han, Aiguo
    Sirlin, Claude B.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2025, 51 (03): : 475 - 483
  • [44] Quantitative assessment of normal middle deltoid muscle elasticity at various arm abduction using ultrasound shear wave elastography
    Wang, Lei
    Guo, Xuanyan
    Tan, Li
    Chen, Qin
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [45] Correlates of Calcaneal Quantitative Ultrasound Parameters in Patients with Diabetes: The Study on the Assessment of Determinants of Muscle and Bone Strength Abnormalities in Diabetes
    Conti, Francesco
    Balducci, Stefano
    Pugliese, Luca
    D'Errico, Valeria
    Vitale, Martina
    Alessi, Elena
    Salerno, Gerardo
    Iacobini, Carla
    Menini, Stefano
    Bollanti, Lucilla
    Nicolucci, Antonio
    Pugliese, Giuseppe
    JOURNAL OF DIABETES RESEARCH, 2017, 2017
  • [46] Quantitative assessment of normal middle deltoid muscle elasticity at various arm abduction using ultrasound shear wave elastography
    Lei Wang
    Xuanyan Guo
    Li Tan
    Qin Chen
    Scientific Reports, 11
  • [47] LONGITUDINAL CHANGES IN BONE STRUCTURE AS ASSESSED BY PERIPHERAL QUANTITATIVE COMPUTED TOMOGRAPHY AND RELATIONSHIPS WITH MUSCLE HEALTH IN OLDER MEN AND WOMEN
    Edwards, M. H.
    Ward, K. A.
    Jameson, K. A.
    Dennison, E. M.
    Cooper, C.
    OSTEOPOROSIS INTERNATIONAL, 2016, 27 : S48 - S48
  • [48] Accuracy of ultrasound, bioelectrical impedance analysis and anthropometry as point-of-care measurements of skeletal muscle mass in patients with inflammatory bowel disease
    Nguyen, Anke L.
    Burns, Megan
    Herath, Madhuni
    Lambell, Kate
    Holt, Darcy
    Fitzpatrick, Jessica
    Milat, Frances
    Ebeling, Peter R.
    Gibson, Peter R.
    Moore, Gregory T.
    ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2023, 58 (03) : 309 - 321
  • [49] Pilot Study on Quantitative Assessment of Muscle Imbalance: Differences of Muscle Synergies, Equilibrium-point Trajectories, and Endpoint Stiffness in Normal and Pathological Upper-limb Movements
    Oku, Takanori
    Uno, Kanna
    Nishi, Tomoki
    Kageyama, Masayuki
    Phatiwuttipat, Pipatthana
    Koba, Keitaro
    Yamashita, Yuto
    Murakami, Kenta
    Uemura, Mitsunori
    Hirai, Hiroaki
    Miyazaki, Fumio
    Naritomi, Hiroaki
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 5784 - 5787
  • [50] Long-term assessment of morphological, functional, and quantitative parameters of skeletal muscle in older patients after unilateral total hip arthroplasty
    Yoshiko, Akito
    Beppu, Moroe
    Izumida, Ryoichi
    Matsubara, Masaaki
    Otani, Takuya
    Shiratsuchi, Hideaki
    Takahira, Naonobu
    Moritani, Toshio
    Watanabe, Kohei
    EXPERIMENTAL GERONTOLOGY, 2020, 137