Point of Care Quantitative Assessment of Muscle Health in Older Individuals: An Investigation of Quantitative Muscle Ultrasound and Electrical Impedance Myography Techniques

被引:14
|
作者
Hobson-Webb, Lisa D. [1 ]
Zwelling, Paul J. [1 ]
Pifer, Ashley N. [1 ]
Killelea, Carrie M. [2 ,3 ]
Faherty, Mallory S. [2 ,3 ]
Sell, Timothy C. [2 ,3 ]
Pastva, Amy M. [2 ,4 ]
机构
[1] Duke Univ, Dept Neurol, Neuromuscular Div, Durham, NC 27710 USA
[2] Duke Univ, Dept Orthopaed Surg, Durham, NC 27710 USA
[3] Michael W Krzyzewski Human Performance Lab, Durham, NC 27710 USA
[4] Duke Univ, Claude D Pepper Older Amer Independence Ctr, Durham, NC 27710 USA
关键词
elderly; aging; muscle; ultrasound; electrical impedance myography; point of care; TUG; frailty;
D O I
10.3390/geriatrics3040092
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
Background: Muscle health is recognized for its critical role in the functionality and well-being of older adults. Readily accessible, reliable, and inexpensive methods of measuring muscle health are needed to advance research and clinical care. Methods: In this prospective, blinded study, 27 patients underwent quantitative muscle ultrasound (QMUS), standard electrical impedance myography (sEIM), and handheld electrical impedance myography (hEIM) of the anterior thigh musculature by two independent examiners. Subjects also had dual-energy X-ray absorptiometry (DEXA) scans and standardized tests of physical function and strength. Data were analyzed for intra- and inter-rater reliability, along with correlations with DEXA and physical measures. Results: Measures of intra- and inter-rater reliability were excellent (>0.90) for all QMUS, sEIM, and hEIM parameters except intra- rater reliability of rectus femoris echointensity (0.87-0.89). There were moderate, inverse correlations between QMUS, sEIM, and hEIM parameters and measures of knee extensor strength. Moderate to strong correlations (0.57-0.81) were noted between investigational measures and DEXA-measured fat mass. Conclusions: QMUS, sEIM and hEIM were highly reliable in a controlled, same-day testing protocol. Multiple correlations with measures of strength and body composition were noted for each method. Point-of-care technologies may provide an alternative means of measuring health.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Electrical impedance myography combined with quantitative assessment techniques in paretic muscle of stroke survivors: Insights and challenges
    Gong, Ze
    Lo, Wai Leung Ambrose
    Wang, Ruoli
    Li, Le
    FRONTIERS IN AGING NEUROSCIENCE, 2023, 15
  • [2] Electrical Impedance Myography and Quantitative Ultrasound for Assessment of Duchenne Muscular Dystrophy
    Parad, Rebecca
    Wilder, Sarah
    Pasternak, Amy
    Shriber, Elizabeth
    Visyak, Nicole
    Geisbush, Thomas
    Wu, Jim
    Zaidman, Craig
    Darras, Basil
    Rutkove, Seward
    ANNALS OF NEUROLOGY, 2013, 74 : S101 - S102
  • [3] INNOVATIVE ASSESSMENT OF MUSCLE INJURY USING ELECTRICAL IMPEDANCE MYOGRAPHY
    Sanchez, Benjamin
    Iyer, Shama
    Li, Jia
    Lovering, Richard
    Rutkove, Seward
    MUSCLE & NERVE, 2016, 54 (03) : 529 - 529
  • [4] Electrical impedance myography in the assessment of age-associated muscle change
    Esper, GJ
    Lee, KS
    Aaron, R
    Shiffman, CA
    Bradonjic, K
    Rutkove, SB
    MUSCLE & NERVE, 2005, 32 (03) : 403 - 403
  • [5] Quantitative muscle ultrasound and electrical impedance myography in late onset Pompe disease: A pilot study of reliability, longitudinal change and correlation with function
    Hobson-Webb, Lisa D.
    Zwelling, Paul J.
    Raja, Shruti S.
    Pifer, Ashley N.
    Kishnani, Priya S.
    MOLECULAR GENETICS AND METABOLISM REPORTS, 2021, 28
  • [6] Exploring the relationship between electrical impedance myography and quantitative ultrasound parameters in Duchenne muscular dystrophy
    Roy, Bhaskar
    Darras, Basil T.
    Zaidman, Craig M.
    Wu, Jim S.
    Kapur, Kush
    Rutkove, Seward B.
    CLINICAL NEUROPHYSIOLOGY, 2019, 130 (04) : 515 - 520
  • [7] TWO INNOVATIVE METHODS FOR QUANTIFYING TONGUE HEALTH: ELECTRICAL IMPEDANCE MYOGRAPHY AND QUANTITATIVE ULTRASONOGRAPHY
    McIlduff, Courtney E.
    Geisbush, Tom R.
    Mijailovic, Aleksandar S.
    Rutkove, Seward B.
    MUSCLE & NERVE, 2014, 50 (04) : 629 - 629
  • [8] Electrical Impedance Myography and Quantitative Ultrasound Detect Steroid Related Improvements in Duchenne Muscular Dystrophy
    Rutkov, Seward
    Zaidman, Craig
    Wu, Jim
    Pastemak, Amy
    Madabusi, Lavanya
    Szelag, Heather
    Harrington, Tim
    Pacheck, Adam
    Yim, Sung
    Kapur, Kush
    Darras, Basil
    NEUROLOGY, 2016, 86
  • [9] CORRELATION BETWEEN ELECTRICAL IMPEDANCE MYOGRAPHY AND TWO QUANTITATIVE ULTRASOUND PARAMETERS IN DUCHENNE MUSCULAR DYSTROPHY
    Roy, Bhaskar
    Darras, Basil
    Zaidman, Craig
    Wu, Jim
    Kapur, Kush
    Rutkove, Seward
    MUSCLE & NERVE, 2018, 58 : S6 - S6
  • [10] Electrical Impedance Myography for the Non-Invasive Assessment of Muscle in Spinal Muscular Atrophy
    Rutkove, Seward B.
    ANNALS OF NEUROLOGY, 2009, 66 : S2 - S2