Comparative Study of Solar Water Heating Systems - Flat Plate Collector (FPC) with Evacuated Tube Collector

被引:18
|
作者
David, Jefferson Stanley [1 ]
Viveckraj, Jayaraman [1 ]
Sivamani, Seralathan [1 ]
Varatharajan, K. [2 ]
机构
[1] Hindustan Inst Technol & Sci Padur, Dept Mech Engn, Madras 603103, Tamil Nadu, India
[2] Tapovan Senior Citizens Fdn, Coimbatore 641010, Tamil Nadu, India
关键词
Solar water heater; Evacuated tube collector; Flat plate collector; Performance; Coimbatore city;
D O I
10.4028/www.scientific.net/JERA.26.76
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Solar energy is one of the alternatives to replace the use of conventional energy sources to heat water for domestic use. This paper focuses on the design and fabrication of a second generation indigenized FPC with locally available low cost material and compares its performance with existing costlier ETC solar water heating system. Readings of FPC and ETC are taken on different days at different time intervals having varied climatic conditions and humidity levels. Analysis of data showed that the rate of temperature rise in ETC is higher than FPC. The maximum temperature reached by these two solar water heating system varies from 2 degrees C to 4 degrees C. The difference between ETC and the indigenized FPC is the time taken to reach the peak temperature. This is due to a better conversion factor and a comparatively low thermal loss factor of ETC. Considering the energy saving involved, as the difference in temperature between FPC and ETC ranges from 0.10 degrees C to 6.80 degrees C, FPC is better suited to heat water for domestic uses given the climatic conditions prevailing in Coimbatore city, India.
引用
收藏
页码:76 / 85
页数:10
相关论文
共 50 条
  • [21] Performance analysis of evacuated tube solar collector for residential heating in Mongolia
    Purevdalai, E.
    Amarbayar, A.
    Akisawa, Atsushi
    PROCEEDINGS OF THE ISES SOLAR WORLD CONFERENCE 2015, 2015, : 1120 - 1126
  • [22] A Comparative Study on the Performances of Flat Plate and Evacuated Tube Collectors Deployable in Domestic Solar Water Heating Systems in Different Climate Areas
    Greco, Adriana
    Gundabattini, Edison
    Gnanaraj, Darius S.
    Masselli, Claudia
    CLIMATE, 2020, 8 (06)
  • [23] Failure Investigation of Evacuated Tube Solar Collector of Water Heater
    Siddharaj V. Kumbhar
    Journal of Failure Analysis and Prevention, 2019, 19 : 1202 - 1206
  • [24] WATER DESALINATION BY EVACUATED TUBE HEAT PIPE SOLAR COLLECTOR
    Alwaer, A.
    Gryzagoridis, J.
    PROCEEDINGS OF THE 2014 11TH INTERNATIONAL CONFERENCE ON THE INDUSTRIAL AND COMMERCIAL USE OF ENERGY (ICUE), 2014, : 364 - 368
  • [25] Failure Investigation of Evacuated Tube Solar Collector of Water Heater
    Kumbhar, Siddharaj V.
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2019, 19 (05) : 1202 - 1206
  • [26] NUMERICAL ANALISYS OF A WATER HEATING SYSTEM USING A FLAT PLATE SOLAR COLLECTOR
    Quitiaquez, William
    Estupinan-Campos, Jose
    Isaza-Roldan, C. A.
    Toapanta-Ramos, Fernando
    Lobato-Campoverde, Andres
    INGENIUS-REVISTA DE CIENCIA Y TECNOLOGIA, 2020, (24): : 97 - 106
  • [27] New Evacuated Tube Solar Collector with Parabolic Trough Collector and Helical Coil Heat Exchanger for Usage in Domestic Water Heating
    Said, Sana
    Mellouli, Sofiene
    Alqahtani, Talal
    Algarni, Salem
    Ajjel, Ridha
    SUSTAINABILITY, 2023, 15 (15)
  • [28] Performance Analysis of Solar Evacuated Tube Collector
    Fang, Wenbo
    ADVANCES IN MANUFACTURING SCIENCE AND ENGINEERING, PTS 1-4, 2013, 712-715 : 1605 - 1608
  • [29] PERFORMANCE OF AN EVACUATED GLASS TUBE SOLAR COLLECTOR INTEGRATED WITH A SOLAR HEATING SYSTEM.
    Ward, John C.
    Ward, Dan S.
    1600, Am Sect of Int Sol Energy Soc, Inc, Univ of DelNewark (2 .):
  • [30] Experimental study on thermal loss of solar evacuated tube collector
    School of Mechanical Engineering, Shanghai Jiaotong University, Shanghai 200030, China
    不详
    不详
    Taiyangneng Xuebao, 2007, 10 (1063-1068):