Optimal office lighting use: a Swedish case study

被引:6
|
作者
Maleetipwan-Mattsson, Pimkamol [1 ]
Laike, Thorbjorn [1 ]
机构
[1] Lund Univ, Dept Architecture & Built Environm, Environm Psychol, Lund, Sweden
关键词
Individual; Energy saving; Lighting; Office; Lighting control; Occupancy;
D O I
10.1108/F-01-2014-0004
中图分类号
C93 [管理学];
学科分类号
12 ; 1201 ; 1202 ; 120202 ;
摘要
Purpose - The purpose of this paper is to determine the optimal office lighting use with different types of lighting controls to achieve energy savings and provide visual comfort for individuals. Design/methodology/approach - A case study and field measurements were carried out in 18 single-occupancy offices in Sweden where six different lighting controls were investigated. Occupancy and daylight hours were key issues for determining the lighting use. For each office, occupancy patterns, use of a ceiling luminaire, energy usage and perceptions of office lighting in the spring-summer and autumn-winter were established. Findings - The use of luminaires varied among the occupants and could be habitual. Though the study yielded positive results concerning the potential for manual or daylight dimming with occupancy switch-off controls to increase optimal lighting use, combining dimming controls with manual on/off controls is rather effective if occupants generally sit in their offices most of the day. Research limitations/implications - Precise comparisons of the performances of the different controls were limited due to the offices' different window orientations; thus, measurements in identical offices are desirable. The small sample size limited analyses of lighting use and the personal perceptions of lighting quality. Practical implications - Apart from the contribution to simulation techniques, the findings imply that office lighting controls should be selected taking individuals' behavioural patterns and perceived lighting quality into consideration. Originality/value - This paper describes an approach to determine the use of lighting controls and provides a basis for establishing optimal lighting use for individuals with regard to occupancy and daylight availability.
引用
收藏
页码:573 / 587
页数:15
相关论文
共 50 条
  • [1] Prudential-Healthcare: An office lighting case study
    Rodgers, P
    Miller, N
    ARCHITECTURAL RECORD, 1997, 185 (02) : 154 - 157
  • [2] Analysis of daylight glare and optimal lighting design for comfortable office lighting
    Sun, Yue
    Liu, Xin
    Qu, Wenjie
    Cao, Guanying
    Zou, Nianyu
    OPTIK, 2020, 206
  • [3] Factors affecting optimal lighting use in shared hospital environments: A case-study
    Maleetipwan-Mattsson, Pimkamol
    Laike, Thorbjorn
    Johansson, Maria
    BUILDING AND ENVIRONMENT, 2016, 96 : 260 - 269
  • [4] User Preferences in Office Lighting: A Case Study Comparing LED and T5 Lighting
    Viitanen, Janne
    Lehtovaara, Jorma
    Tetri, Eino
    Halonen, Liisa
    LEUKOS, 2013, 9 (04) : 261 - 290
  • [5] OFFICE LIGHTING SYSTEM SAVES ENERGY USE
    不详
    EC&M-ELECTRICAL CONSTRUCTION AND MAINTENANCE, 1983, 82 (06): : 60 - 62
  • [6] Optimal metering plan for measurement and verification on a lighting case study
    Ye, Xianming
    Xia, Xiaohua
    ENERGY, 2016, 95 : 580 - 592
  • [7] A CASE-STUDY OF OFFICE WORKSTATION USE
    BULLEN, CV
    BENNETT, JL
    CARLSON, ED
    IBM SYSTEMS JOURNAL, 1982, 21 (03) : 351 - 369
  • [8] ENERGY EFFICIENT HUMAN CENTERED OFFICE LIGHTING: A CASE STUDY ON OPEN PLAN OFFICE WITH ABSENT ACCESS TO DAYLIGHT
    Aliparast, Sevda
    Onaygil, Sermin
    LIGHT & ENGINEERING, 2023, 31 (06): : 102 - 108
  • [9] OFFICE LIGHTING
    GUTH, FE
    FORTUNE, 1978, 97 (02) : 49 - 49
  • [10] OFFICE LIGHTING
    RIDGWAY, B
    ARCHITECTURAL REVIEW, 1986, 180 (1078) : 78 - &