VENTRICULAR-TACHYCARDIA - AN UNUSUAL PACEMAKER-MEDIATED TACHYCARDIA - ABSTRACTS

被引:0
|
作者
LEFROY, DC
CRAKE, T
DAVIES, DW
机构
[1] NATL HEART & LUNG INST,DEPT CARDIAC MED,LONDON SW3 6LY,ENGLAND
[2] ST MARYS HOSP,DEPT CARDIOL,LONDON W2 1NY,ENGLAND
来源
BRITISH HEART JOURNAL | 1994年 / 71卷 / 05期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A 74 year old man had recurrent ventricular tachycardia, which was well controlled with amiodarone, and complete heart block for which a VVI permanent pacing system had previously been implanted. After an elective increase in the programmed pacemaker rate from 70 to 82 beats/min, there was recurrence of frequent episodes of ventricular tachycardia. Each episode of tachycardia was initiated by a fusion beat consisting of a ventricular extrasystole and a paced beat. When the pacemaker rate was reprogrammed to 70 beats/min the episodes of tachycardia ceased abruptly. It is proposed that the fusion of a ventricular extrasystole with a pacemaker beat may have induced ventricular tachycardia, even though neither of these beats occurring separately was sufficient to cause this.
引用
收藏
页码:481 / 483
页数:3
相关论文
共 50 条
  • [41] Catheter Ablation of Accessory Pathway in the Treatment of Pacemaker-Mediated Tachycardia
    Robledo-Nolasco, Rogelio
    Ortiz-Avalos, Martin
    Rodriguez-Diez, Gerardo
    Castro-Villacorta, Humberto
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (04): : e74 - e76
  • [42] Accuracy of the pacemaker-mediated tachycardia algorithm in Boston Scientific devices
    Strik, M.
    Frontera, A.
    Eschalier, R.
    Defaye, P.
    Mondoly, P.
    Ritter, P.
    Haissaguerre, M.
    Ploux, S.
    Bordachar, P.
    JOURNAL OF ELECTROCARDIOLOGY, 2016, 49 (04) : 522 - 529
  • [43] Pacemaker-mediated tachycardia with varying cycle length: what is the mechanism?
    Verrijcken, Anton
    Huybrechts, Wim
    Willems, Rik
    EUROPACE, 2009, 11 (10): : 1400 - 1402
  • [44] Atypical Initiation of Endless-Loop, Pacemaker-Mediated Tachycardia
    Bhattacharya, Sanjoy
    Wang, Norman C.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2011, 34 (05): : 617 - 620
  • [45] Validation of device algorithm to differentiate pacemaker-mediated tachycardia from tachycardia due to atrial tracking
    Ip, James E.
    Lerman, Bruce B.
    HEART RHYTHM, 2016, 13 (08) : 1612 - 1617
  • [46] ENTRAINMENT OF VENTRICULAR-TACHYCARDIA IN ARRHYTHMOGENIC RIGHT VENTRICULAR-TACHYCARDIA
    AIZAWA, Y
    FUNAZAKI, T
    TAKAHASHI, M
    NAITOH, N
    MIYAJIMA, T
    KUSANO, Y
    SHIBATA, A
    MISAKI, T
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (11): : 1606 - 1613
  • [47] PACEMAKER-MEDIATED TACHYCARDIA - A COMPLICATION OF ATRIOVENTRICULAR UNIVERSAL (DDD) PACEMAKERS
    GREENBERG, RM
    GREENSPON, AJ
    BRIDENBAUGH, A
    BREST, AN
    ARCHIVES OF INTERNAL MEDICINE, 1984, 144 (05) : 1061 - 1063
  • [48] Termination of pacemaker-mediated tachycardia by a critically timed atrial extrasystole
    Barold, S. Serge
    Strooband, Roland
    Van Heuverswyn, Frederic
    Herweg, Bengt
    CARDIOLOGY JOURNAL, 2012, 19 (04) : 443 - 444
  • [49] Etomidate unlikely to have induced pacemaker-mediated tachycardia -: Reply
    Altose, Michael D.
    Leon-Ruiz, Elias
    ANESTHESIOLOGY, 2007, 107 (06) : 1037 - 1037
  • [50] CATHETER ABLATION OF VENTRICULOATRIAL CONDUCTION IN THE TREATMENT OF PACEMAKER-MEDIATED TACHYCARDIA