Reliability and validity of the five-repetition sit-to-stand test in adult kidney transplant recipients

被引:5
|
作者
Huang, Katherin S. [1 ]
O'Connor, Ellen [2 ,3 ]
Tuffnell, Rachel [2 ,3 ]
Lindup, Herolin [2 ,3 ]
Macdougall, Iain C. [4 ,5 ]
Greenwood, Sharlene A. [5 ,6 ,7 ]
机构
[1] Singapore Gen Hosp, Dept Physiotherapy, Singapore, Singapore
[2] Kings Coll Hosp London, Renal Med Dept, London, England
[3] Kings Coll Hosp London, Physiotherapy Dept, London, England
[4] Kings Coll Hosp London, Dept Renal Med, Clin Nephrol, London, England
[5] Kings Coll London, Div Transplantat Immunol & Mucosal Biol, Dept Renal Med, London, England
[6] Kings Coll London, Renal Med Dept, London, England
[7] Kings Coll London, Physiotherapy Dept, London, England
关键词
Kidney transplantation; Muscle strength; Physical function; Rehabilitation;
D O I
10.12968/ijtr.2018.25.4.158
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background/Aims: To investigate the reliability and validity of the five-repetition sit-to-stand test (FRSTST) to assess lower-limb muscle strength and physical function in adult kidney transplant recipients.& para;& para;Methods: A cross-sectional, observational study was conducted in a secondary care centre. A convenience sample of 56 adult kidney transplant recipients were recruited following a 6-week post-transplantation recovery period. The participants were within their first 18 months of kidney transplantation. The measurements included FRSTST times, myometer measurements of isometric quadriceps muscle strength, 60-second sit-to-stand test (STS60) scores, and Duke Activity Status Index (DASI) scores.& para;& para;Findings: Inter- and intratester reliability of the FRSTST were excellent (intraclass correlation coefficients 0.997 and 0.970, respectively). The standard error of measurement and the minimal detectable change at 95% confidence level were 0.9 and 2.5 seconds, respectively. The best FRSTST scores by the two testers had non-significant, weak correlations with the isometric quadriceps muscle force (Spearman's rho, r(s)=-0.04, p=0.76), and quadriceps muscle torque (r(s)=0.04, p=0.76). The FRSTST correlated significantly with the STS60 (r(s)=-0.90, p=0.001) and DASI scores (r(s)=-0.49, p=0.001).& para;& para;Conclusions: The FRSTST can be considered to be a reliable test of physical function for adult kidney transplant recipients, but may not be used as a surrogate measure of lower limb muscle strength in this population.
引用
收藏
页码:158 / 166
页数:9
相关论文
共 50 条
  • [41] Can objective functional impairment in lumbar degenerative disease be reliably assessed at home using the five-repetition sit-to-stand test? A prospective study
    Staartjes, Victor E.
    Beusekamp, Femke
    Schroder, Marc L.
    EUROPEAN SPINE JOURNAL, 2019, 28 (04) : 665 - 673
  • [42] The five times sit-to-stand test: safety, validity and reliability with critical care survivors’s at ICU discharge
    Thiago Araújo de Melo
    Fernando Silva Guimarães
    José Roberto Lapa e Silva
    Archives of Physiotherapy, 13
  • [43] The five times sit-to-stand test: safety, validity and reliability with critical care survivors's at ICU discharge
    de Melo, Thiago Araujo
    Silva Guimaraes, Fernando
    Lapa e Silva, Jose Roberto
    ARCHIVES OF PHYSIOTHERAPY, 2022, 13 (01)
  • [44] Reliability and validity of sit-to-stand test protocols in patients with coronary artery disease
    Wang, Zheng
    Yan, Jianhua
    Meng, Shu
    Li, Jiajia
    Yu, Yi
    Zhang, Tingting
    Tsang, Raymond C. C.
    El-Ansary, Doa
    Han, Jia
    Jones, Alice Y. M.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [45] The minimal important difference (MID) of the five-repetition sit to stand test (5STS) in IPF
    Trivedi, P.
    Polgar, O.
    Patel, S.
    Barker, R.
    Man, W.
    Nolan, C.
    EUROPEAN RESPIRATORY JOURNAL, 2022, 60
  • [46] Modified 30-Second Sit-to-Stand Test: Reliability and Validity in Older Adults Unable to Complete Traditional Sit-to-Stand Testing
    McAllister, Linda S.
    Palombaro, Kerstin M.
    JOURNAL OF GERIATRIC PHYSICAL THERAPY, 2020, 43 (03) : 153 - 158
  • [47] Can objective functional impairment in lumbar degenerative disease be reliably assessed at home using the five-repetition sit-to-stand test? A prospective study
    Victor E. Staartjes
    Femke Beusekamp
    Marc L. Schröder
    European Spine Journal, 2019, 28 : 665 - 673
  • [48] A single trial of the five-repetition sit-to-stand test provides adequate measures in community-dwelling older adults: A cross-sectional study
    de Brito, Sherindan Ayessa Ferreira
    Benfica, Poliana do Amaral Yamaguchi
    Aguiar, Larissa Tavares
    Gomes, Gisele de Cassia
    Faria, Christina Danielli Coelho de Morais
    JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2024, 39 : 536 - 540
  • [49] Can the five repetition sit-to-stand test discriminate inpatients and outpatients with acute exacerbations of COPD?
    Machado, Ana
    Oliveira, Ana
    Vieira, Marta
    Valente, Carla
    Januario, Filipa
    Pires De Dias Marques, Alda Sofia
    EUROPEAN RESPIRATORY JOURNAL, 2019, 54
  • [50] Clinical measurement of sit-to-stand performance in people with balance disorders: Validity of data for the five-times-sit-to-stand test
    Whitney, SL
    Wrisley, DM
    Marchetti, GF
    Gee, MA
    Redfern, MS
    Furman, JM
    PHYSICAL THERAPY, 2005, 85 (10): : 1034 - 1045