Investigation of postoperative intraocular pressure in cases of silicone oil removal using 25-gauge transconjunctival sutureless vitrectomy with oblique incisions

被引:2
|
作者
Takashina, Hirotsugu [1 ,2 ]
Watanabe, Akira [2 ]
Tsuneoka, Hiroshi [2 ]
机构
[1] Natl Hosp Org Sagamihara Hosp, Dept Ophthalmol, Sagamihara, Kanagawa, Japan
[2] Jikei Univ, Sch Med, Dept Ophthalmol, Minato Ku, Tokyo 1058471, Japan
来源
CLINICAL OPHTHALMOLOGY | 2015年 / 9卷
关键词
sclerotomy leakage; self-sealing; silicone oil tamponade; remnant vitreous; hypotony; idiopathic epiretinal membrane;
D O I
10.2147/OPTH.S93376
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: The purpose of this study was to investigate postoperative intraocular pressure (IOP) in cases of silicone oil (SO) removal when using 25-gauge transconjunctival sutureless vitrectomy (TSV) with oblique incisions. Methods: We enrolled ten consecutive eyes with SO removal (SO group) and eleven consecutive eyes with idiopathic epiretinal membrane (ERM) as the initial vitrectomy (ERM group) in cases using 25-gauge TSV with oblique incisions. Postoperative IOPs were compared between the two groups at each of the four examination periods. Results: No significant differences were identified in any of the periods examined. Conclusion: The use of 25-gauge TSV with oblique incisions resulted in almost equivalent postoperative IOPs between cases with SO removal and idiopathic ERM as the initial operation. Self-sealing sclerotomy in 25-gauge TSV with oblique incisions may primarily involve the valve architecture, and be complemented by vitreous incarceration.
引用
收藏
页码:1925 / 1928
页数:4
相关论文
共 50 条
  • [21] Passive removal of silicone oil with a 25-gauge sutureless system
    Ziya Kapran
    Nur Acar
    Yaprak Banu Unver
    Tugrul Altan
    Bulut Ocak
    Japanese Journal of Ophthalmology, 2008, 52 : 63 - 66
  • [22] Decompression retinopathy after 25-gauge transconjunctival sutureless vitrectomy:: Report of 2 cases
    Rezende, Flavio A.
    Regis, Luiz Gustavo T.
    Kickinger, Monica
    Alcantara, Simone
    ARCHIVES OF OPHTHALMOLOGY, 2007, 125 (05) : 699 - 700
  • [23] Active removal of silicone oil with 25-gauge sutureless system
    Kapran, Ziya
    Acar, Nur
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2007, 27 (08): : 1133 - 1135
  • [24] A new 25-gauge instrument system for transconjunctival sutureless vitrectomy surgery
    Fujii, GY
    de Juan, E
    Humayun, MS
    Pieramici, DJ
    Chang, TS
    Ng, E
    Barnes, A
    Wu, SL
    Sommerville, DN
    OPHTHALMOLOGY, 2002, 109 (10) : 1807 - 1812
  • [25] Influence of silicone oil tamponade on self-sealing sclerotomy using 25-gauge transconjunctival sutureless vitrectomy: a retrospective comparative study
    Takashina, Hirotsugu
    Watanabe, Akira
    Tsuneoka, Hiroshi
    BMC OPHTHALMOLOGY, 2015, 15
  • [26] Longer-term outcomes of transconjunctival sutureless 25-gauge vitrectomy
    Ibarra, MS
    Hermel, M
    Prenner, JL
    Hassan, TS
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 139 (05) : 831 - 836
  • [27] Safety of transconjunctival sutureless 25-gauge vitrectomy in eyes with prior 20-Gauge vitrectomy
    Noffke, AS
    Sarrafizadeh, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [28] Corneal topographic changes after transconjunctival (25-gauge) sutureless vitrectomy
    Yanyali, A
    Celik, E
    Horozoglu, F
    Nohutcu, AF
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 140 (05) : 939 - 941
  • [29] Influence of silicone oil tamponade on self-sealing sclerotomy using 25-gauge transconjunctival sutureless vitrectomy: a retrospective comparative study
    Hirotsugu Takashina
    Akira Watanabe
    Hiroshi Tsuneoka
    BMC Ophthalmology, 15
  • [30] Wound leakage and hypotony after 25-gauge sutureless vitrectomy: Factors affecting postoperative intraocular pressure
    Byeon, Suk Ho
    Lew, Youngju
    Kim, Min
    Kwon, Oh W.
    OPHTHALMIC SURGERY LASERS & IMAGING, 2008, 39 (02) : 94 - 99