Impulse response measurement using colored pseudo noise with low crest factor

被引:0
|
作者
Shinohara, Ryo [1 ]
Kaneda, Yutaka [1 ]
机构
[1] Tokyo Denki Univ, Grad Sch Engn, Chiyoda Ku, 5 Senzyu Asahi Cho, Tokyo 1208551, Japan
关键词
Impulse response measurement; Colored pseudo noise; Crest factor reduction; Minimum noise;
D O I
10.1250/ast.35.321
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
[No abstract available]
引用
收藏
页码:321 / 323
页数:3
相关论文
共 50 条
  • [31] Op-Amp Gain-Bandwidth Measurement using Impulse Response
    Nieva, John Mark M.
    Magwili, Glenn V.
    Cruz, Febus Reidj G.
    2020 6TH INTERNATIONAL CONFERENCE ON COMMUNICATION AND INFORMATION PROCESSING, ICCIP 2020, 2020, : 140 - 147
  • [32] On Room Impulse Response Measurement Using Perfect Sequences for Wiener Nonlinear Filters
    Carini, A.
    Cecchi, S.
    Terenzi, A.
    Orcioni, S.
    2018 26TH EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO), 2018, : 982 - 986
  • [33] MEASUREMENT OF THE DISPERSION PARAMETER OF A LECLANCE CELL USING ITS IMPULSE-RESPONSE
    CHABLI, A
    DIARD, JP
    LEGORREC, B
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 1982, 12 (05) : 585 - 590
  • [34] Synthesis of two-dimensional pseudo white-noise signal with low peak factor
    Hayashi, T
    IEEE SIGNAL PROCESSING LETTERS, 2004, 11 (10) : 813 - 816
  • [35] High-amplitude impulse noise: Measurement of hearing protector attenuation using a shock tube
    Birch, Robert S.
    Vergara, Erasmo F.
    Gerges, Samir
    NOISE CONTROL ENGINEERING JOURNAL, 2009, 57 (06) : 585 - 594
  • [36] Accurate MTF measurement in digital radiography using noise response
    Kuhls-Gilcrist, Andrew
    Jain, Amit
    Bednarek, Daniel R.
    Hoffmann, Kenneth R.
    Rudin, Stephen
    MEDICAL PHYSICS, 2010, 37 (02) : 724 - 735
  • [37] Multi-frequency simultaneous measurement of bioimpedance spectroscopy based on a low crest factor multisine excitation
    Yang, Yuxiang
    Zhang, Fu
    Tao, Kun
    Wang, Lianhuan
    Wen, He
    Teng, Zhaosheng
    PHYSIOLOGICAL MEASUREMENT, 2015, 36 (03) : 489 - 501
  • [38] Measurement of binary diffusion coefficient from impulse response curve having extremely low absorbance intensity under supercritical condition by noise elimination technique
    Funazukuri, T
    Kong, CY
    Kagei, S
    FLUID PHASE EQUILIBRIA, 2004, 220 (02) : 181 - 188
  • [39] Low complexity crest factor reduction for forward link CDMA using IQ offset
    Qian, Hua
    Zhao, Chunming
    Zhou, G. Tong
    2007 IEEE/SP 14TH WORKSHOP ON STATISTICAL SIGNAL PROCESSING, VOLS 1 AND 2, 2007, : 413 - +
  • [40] A Low Cost Image De-noising Implementation Using Low Area CSLA for Impulse Noise Removal
    Bommy, B.
    Raj, A. Albert
    JOURNAL OF CIRCUITS SYSTEMS AND COMPUTERS, 2018, 27 (04)