Energy and Exergy Analysis of 210 MW Jamshoro Thermal Power Plant

被引:0
|
作者
Rajper, Muhib Ali [1 ]
Memon, Abdul Ghafoor [2 ]
Harijan, Khanji [2 ]
机构
[1] Jamshoro Power Co Ltd, Jamshoro, Pakistan
[2] Mehran Univ Engn & Technol, Dept Mech Engn, Jamshoro, Pakistan
关键词
Energy; Exergy; Efficiency; Steam Power Plant; Parametric Study;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, thermodynamic analysis of 210 MW dual-fire, subcritical, reheat steam power plant, situated near Jamshoro, Pakistan has been performed. Firstly, the plant is modeled by EES (Engineering Equation Solver) software. Moreover; a parametric study is performed to assess the impacts of various operating parameters on the performance. The net power output, energy efficiency and exergy efficiency are considered as performance parameters of the plant whereas, condenser pressure, main steam pressure and main steam temperature are nominated as operating parameters. According to the results, the net power output, energy efficiency and exergy efficiency are determined as 186.5 MW, 31.37% and 30.41% respectively, under design operating conditions. The condenser contributed a major share in the total energy loss i.e. 280 MW (68.7%) followed by boiler with 89 MW (21.8%). The major exergy destructing area is found in the boiler with 350 MW (82.11%) of the total exergy destruction followed by turbine with 43.1 MW (10.12%) and condenser 12 MW (5.74 %). According to the parametric study, variation in operating parameters had great influence on the plant performance.
引用
收藏
页码:265 / 274
页数:10
相关论文
共 50 条
  • [21] Energy and exergy analyses of a solar chimney power plant with thermal energy storage
    Karimi-Pour-Fard, Pedram
    Beheshti, Hamid
    Baniasadi, Ehsan
    INTERNATIONAL JOURNAL OF EXERGY, 2016, 20 (02) : 150 - 169
  • [22] Failure investigation of platen superheater tube in a 210 MW thermal power plant boiler
    Ghosh, D.
    Roy, H.
    Sahoo, T. K.
    Shukla, A. K.
    TRANSACTIONS OF THE INDIAN INSTITUTE OF METALS, 2010, 63 (2-3): : 687 - 690
  • [23] Exergy analysis of operating lignite fired thermal power plant
    Ganapathy, T.
    Alagumurthi, N.
    Gakkhar, R.P.
    Murugesan, K.
    Journal of Engineering Science and Technology Review, 2009, 2 (01) : 123 - 130
  • [24] Failure investigation of platen superheater tube in a 210 MW thermal power plant boiler
    D. Ghosh
    H. Roy
    T. K. Sahoo
    A. K. Shukla
    Transactions of the Indian Institute of Metals, 2010, 63 : 687 - 690
  • [25] Exergy analysis of a thermal power plant using a modeling approach
    Dan Hou
    Shuai Shao
    Yun Zhang
    Su Ling Liu
    Yu Chen
    Shu Shen Zhang
    Clean Technologies and Environmental Policy, 2012, 14 : 805 - 813
  • [26] Exergy analysis of a thermal power plant using a modeling approach
    Hou, Dan
    Shao, Shuai
    Zhang, Yun
    Liu, Su Ling
    Chen, Yu
    Zhang, Shu Shen
    CLEAN TECHNOLOGIES AND ENVIRONMENTAL POLICY, 2012, 14 (05) : 805 - 813
  • [27] Designing a Concentrated Solar Thermal Power Plant Using Energy–Exergy–Economic–Environment Analysis
    Umish Srivastva
    Kumar K.R.
    Malhotra R.K.
    Kaushik S.C.
    Applied Solar Energy (English translation of Geliotekhnika), 2020, 56 (06): : 477 - 489
  • [28] Steady state modeling on energy and exergy analysis of a pulverized coal fired thermal power plant
    Pattanayak, Lalatendu
    Sahu, Jaya Narayan
    ASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, 2015, 10 (06) : 876 - 884
  • [29] Exergy Analysis of Thermal Power Plant for Three Different Loads
    Cehajic, Nurdin
    TEHNICKI GLASNIK-TECHNICAL JOURNAL, 2023, 17 (02): : 160 - 166
  • [30] Exergy Analysis of 300MW Coal-Fired Power Plant
    Li, Yong
    Liu, Lei
    2012 INTERNATIONAL CONFERENCE ON FUTURE ELECTRICAL POWER AND ENERGY SYSTEM, PT A, 2012, 17 : 926 - 932