THE COMBINED INTRACAVERNOUS INJECTION AND STIMULATION TEST - DIAGNOSTIC-ACCURACY

被引:62
|
作者
DONATUCCI, CF [1 ]
LUE, TF [1 ]
机构
[1] UNIV CALIF SAN FRANCISCO,SCH MED,DEPT UROL,SAN FRANCISCO,CA 94143
来源
JOURNAL OF UROLOGY | 1992年 / 148卷 / 01期
关键词
PENILE ERECTION; PROSTAGLANDINS; ALPROSTADIL; IMPOTENCE; DIAGNOSIS; DIFFERENTIAL;
D O I
10.1016/S0022-5347(17)36510-2
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
A retrospective review was done of the results of the combined intracavernous injection and stimulation test, an office based functional test for impotence. In this procedure the quality of erection is assessed 15 minutes after injection of a vasoactive drug. In our series 90 patients did not achieve full rigidity and were instructed to perform genital self-stimulation for 5 minutes before reevaluation. Of the 90 patients 67 (74%) improved with stimulation and 23 (26%) showed no improvement. At 5 minutes after stimulation a decrease in the quality of the erection was found in 25 patients-a finding suggestive of venogenic impotence. When cavernosometry and cavernosography were performed 21 patients (84%) had moderate to severe venous leakage and 4 (16%) showed none. Self-stimulation after diagnostic injection of intracavernous agents can improve patient response, and may better predict the potential success of a therapeutic self-injection program and the diagnosis of suspected venogenic impotence.
引用
收藏
页码:61 / 62
页数:2
相关论文
共 50 条
  • [31] EVALUATION OF DIAGNOSTIC-ACCURACY IN THE CLINICAL SETTING
    RAZ, E
    COHEN, S
    BENBASSAT, J
    ISRAEL JOURNAL OF MEDICAL SCIENCES, 1987, 23 (12): : 1177 - 1180
  • [32] DIAGNOSTIC-ACCURACY OF LUNG CYTOLOGY - TERMINOLOGY
    SUPRUN, HZ
    ACTA CYTOLOGICA, 1985, 29 (02) : 184 - 185
  • [33] EXPOSURE PARAMETERS AND THEIR EFFECTS ON DIAGNOSTIC-ACCURACY
    SVENSON, B
    WELANDER, U
    ANNEROTH, G
    SODERFELDT, B
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1994, 78 (04): : 544 - 550
  • [34] THE DIAGNOSTIC-ACCURACY OF CSF ANALYSES IN STROKE
    BRITTON, M
    HULTMAN, E
    MURRAY, V
    SJOHOLM, H
    ACTA MEDICA SCANDINAVICA, 1983, 214 (01): : 3 - 13
  • [35] DIAGNOSTIC-ACCURACY OF AN AUTOMATED EXTERNAL DEFIBRILLATOR
    STULTS, KR
    BROWN, DD
    MORRISON, BA
    ARONSON, AA
    KERBER, RE
    CIRCULATION, 1984, 70 (04) : 14 - 14
  • [36] DIAGNOSTIC-ACCURACY OF STIFLE ARTHROSCOPY IN THE DOG
    VANGESTEL, MA
    JOURNAL OF THE AMERICAN ANIMAL HOSPITAL ASSOCIATION, 1985, 21 (06) : 757 - 763
  • [37] DIAGNOSTIC-ACCURACY OF AN AUTOMATED EXTERNAL DEFIBRILLATOR
    STULTS, KR
    BROWN, DD
    MORRISON, BA
    ARONSON, AA
    KERBER, RE
    CLINICAL RESEARCH, 1984, 32 (04): : A781 - A781
  • [38] EFFECT OF INTERASSAY PRECISION ON DIAGNOSTIC-ACCURACY
    BAYER, MF
    CLINICAL CHEMISTRY, 1988, 34 (12) : 2605 - 2606
  • [39] THE DIAGNOSTIC-ACCURACY OF SPUTUM AND URINE CYTOLOGY
    KERN, WH
    ACTA CYTOLOGICA, 1988, 32 (05) : 651 - 654
  • [40] DIAGNOSTIC-ACCURACY OF AN OPTIMIZED ENDOTOXINASSAY IN BLOOD
    VANDEVENTER, SJH
    PAUW, W
    TENCATE, JW
    JANSSEN, ME
    BULLER, HR
    STURK, A
    EOS-RIVISTA DI IMMUNOLOGIA ED IMMUNOFARMACOLOGIA, 1986, 6 (03): : 226 - 226