CRYOSURGICAL INSTRUMENTATION AND DEPTH DOSE MONITORING

被引:8
|
作者
TORRE, D
机构
[1] Department of Dermatology, Cornell University Medical College, New York, NY
关键词
D O I
10.1016/0738-081X(90)90065-9
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
The equipment needed for cutaneous cryosurgery is dependent upon the type of lesions to be treated, the frequency of its use, and the dermatologist's expertise in cryosurgery. If the physician wishes occasionally to treat an actinic keratosis or verruca, a small carbon dioxide kit for making CO2 pencils is adequate. (Fig. 5-1). Should a liquid nitrogen source be accessible a small "Thermos" plus cotton swabs will be sufficient (Fig. 5-2). To this might be added Zacarian copper discs (Fig. 5-3) for emersion in the nitrogen for cryoprobe application. For dermatologists wishing to treat many lesions, particularly malignant lesions, an in-office supply of liquid nitrogen and an apparatus to utilize the nitrogen in spray or cryoprobe mode are essential. Hand-held instruments are the most popular, but table-top and hospital-type units are available. For malignant lesions, depth dose monitoring equipment is also necessary. The standard equipment consists of a pyrometer-thermocouple device. Vacuum insulated liquid nitrogen storage dewars can be purchased from the manufacturer, from cryosurgical instrument companies (Frigitronics, Brymill, Tower, Gilmore, etc.) or from the welding supply companies which may deliver the liquid nitrogen. These companies may rent the dewars in various sizes. The 10-liter unit is convenient if office delivery of liquid nitrogen is not available and the physician or his assistant has to transport it from a hospital or some other source. If office delivery is possible, the most practical dewars are in the 25-35 1 range. These units have static holding time from 3 weeks to 3 months, allowing infrequent filling (usually at 2-6-week intervals). The more expensive the unit the longer the static holding time, and consequently, the cheaper the cost of keeping a nitrogen supply on hand. A rocker base for pouring (Fig. 5-4A) can be used for transfer of the nitrogen from the storage dewar to the treatment unit, but a dispenser top (Fig. 5-4B) is superior. These can be purchased from the same sources that furnish the dewar. © 1990.
引用
收藏
页码:48 / 60
页数:13
相关论文
共 50 条
  • [21] Developments in instrumentation for condition monitoring
    Hickman, John
    Noise & vibration control worldwide, 1989, 20 (09): : 238 - 240
  • [22] Instrumentation for Monitoring Animal Movements
    Kutrowski, Tomasz M.
    Meydan, Turgut
    Barnes, John
    Aldoumani, Noor
    Erichsen, Jonathan T.
    2014 IEEE SENSORS, 2014,
  • [23] Monitoring and Instrumentation Best Practice
    Warner, James
    GROUTING 2017: GROUTING, DRILLING, AND VERIFICATION, 2017, (288): : 368 - 378
  • [24] Optical Instrumentation for Bioprocess Monitoring
    Lam, Hung
    Kostov, Yordan
    OPTICAL SENSOR SYSTEMS IN BIOTECHNOLOGY, 2009, 116 : 1 - 28
  • [25] PERFORMANCE MONITORING WITH PLANT INSTRUMENTATION
    EULINGER, RD
    KING, JW
    INSTRUMENTATION IN THE POWER INDUSTRY, VOL 32, 1989, 32 : 243 - 248
  • [26] Program instrumentation in computer monitoring
    Wu, BF
    Peng, CL
    Hu, CG
    Li, W
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON COMPUTER AIDED DESIGN & COMPUTER GRAPHICS, 1999, : 520 - 524
  • [27] INSTRUMENTATION, CONTROL AND MONITORING SYSTEMS
    CHAPELOT, M
    NUCLEAR ENGINEERING INTERNATIONAL, 1971, 16 (182): : 577 - &
  • [28] SURVEY OF INSTRUMENTATION FOR ENVIRONMENTAL MONITORING
    BUDNITZ, RJ
    GRAVEN, RM
    HEALTH PHYSICS, 1972, 23 (03): : 407 - +
  • [29] THE ANESTHESIA INSTRUMENTATION AND MONITORING SPECIALIST
    FRAZIER, WT
    KELLY, PM
    LEWIS, JE
    MEDICAL INSTRUMENTATION, 1985, 19 (03): : 113 - 118
  • [30] NEW ANALYTICAL MONITORING INSTRUMENTATION
    ORIENT, IM
    INDUSTRIAL LABORATORY, 1971, 37 (01): : 155 - &