NONINVASIVE DETECTION OF SUCTION IN AN IMPLANTABLE ROTARY BLOOD PUMP USING NEURAL NETWORKS

被引:16
|
作者
Karantonis, Dean [1 ]
Cloherty, Shaun [2 ]
Lovell, Nigel [2 ]
Mason, David [3 ]
Salamonsen, Robert [4 ]
Ayre, Peter [5 ]
机构
[1] Univ New South Wales, Sch Elect Engn & Telecommun, Sydney, NSW 2052, Australia
[2] Univ New South Wales, Grad Sch Biomed Engn, Sydney, NSW 2052, Australia
[3] Monash Univ, Dept Surg, Melbourne, Vic, Australia
[4] Alfred Hosp, Prahran, Vic 3181, Australia
[5] Ventracor Ltd, Chatswood, NSW 2067, Australia
关键词
Implantable rotary blood pump; suction detection; control strategy; left ventricular assist device;
D O I
10.1142/S1469026808002302
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Granting those heart failure patients who are recipients of an implantable rotary blood pump (iRBP) greater functionality in daily activities is a key long-term strategy currently being pursued by many research groups. A reliable technique for noninvasive detection of the various pumping states, most notably that of ventricular collapse or suction, is an essential component of this strategy. Presented in this study is such a technique, whereby various indicators are derived from the noninvasive pump feedback signals, and a suitable computational methodology developed to classify the pumping states of interest. Clinical telemetry data from ten implant recipients was categorized (with the aid of trans-oesophageal echocardiography) into the normal and suction states. These data are used to develop a pumping state classifier based on an artificial neural network (ANN). Nine indices, derived from the noninvasive impeller speed signal, form the inputs to this ANN classifier. During validation, the resulting ANN classifier achieved a maximum sensitivity of 98.54% (609/618 samples of 5 s in length) and specificity of 99.26% (12,123/12,213 samples) for correct detection of the suction state. The ability to detect the suction state with such a high degree of accuracy provides a critical parameter both for control strategy development, and for clinical care of the implant recipient.
引用
收藏
页码:237 / 247
页数:11
相关论文
共 50 条
  • [1] Detection of Ventricular Suction in an Implantable Rotary Blood Pump Using Support Vector Machines
    Wang, Yu
    Faragallah, George
    Divo, Eduardo
    Simaan, Marwan A.
    [J]. 2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 3318 - 3321
  • [2] Evaluation of Suction Detection During Different Pumping States in an Implantable Rotary Blood Pump
    Ng, Siew-Cheok
    Lim, Einly
    Mason, David G.
    Avolio, Alberto P.
    Lovell, Nigel H.
    [J]. ARTIFICIAL ORGANS, 2013, 37 (08) : E145 - E154
  • [3] Noninvasive pulsatile flow estimation for an implantable rotary blood pump
    Karantonis, Dean M.
    Cloherty, Shaun L.
    Mason, David G.
    Ayre, Peter J.
    Lovell, Nigel H.
    [J]. 2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 1018 - +
  • [4] Noninvasive deadbeat control of an implantable rotary blood pump: A simulation study
    Lim, E.
    Alomari, A. H.
    Savkin, A. V.
    Lovell, N. H.
    [J]. 2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 2855 - 2858
  • [5] A Method for Control of an Implantable Rotary Blood Pump for Heart Failure Patients Using Noninvasive Measurements
    Lim, Einly
    Alomari, Abdul-Hakeem H.
    Savkin, Andrey V.
    Dokos, Socrates
    Fraser, John F.
    Timms, Daniel L.
    Mason, David G.
    Lovell, Nigel H.
    [J]. ARTIFICIAL ORGANS, 2011, 35 (08) : E174 - E180
  • [6] Noninvasive average flow and differential pressure estimation for an implantable rotary blood pump using dimensional analysis
    Lim, Einly
    Karantonis, Dean A.
    Reizes, John A.
    Cloherty, Shaun L.
    Mason, David G.
    Lovell, Nigel H.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (08) : 2094 - 2101
  • [7] State transitions in an implantable rotary blood pump
    Lovell, NH
    Ayre, PJ
    [J]. PROCEEDINGS OF THE SECOND IASTED INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, 2004, : 69 - 72
  • [8] Rotary blood pump: Paracorporeal, implantable, percutaneous?
    Nishida, H
    Koyanagi, K
    [J]. ARTIFICIAL ORGANS, 1997, 21 (07) : 589 - 591
  • [9] Noninvasive average flow estimation for an implantable rotary blood pump: A new algorithm incorporating the role of blood viscosity
    Malagutti, Nicolo
    Karantonis, Dean M.
    Cloherty, Shaun L.
    Ayre, Peter J.
    Mason, David G.
    Salamonsen, Robert F.
    Lovell, Nigel H.
    [J]. ARTIFICIAL ORGANS, 2007, 31 (01) : 45 - 52
  • [10] Noninvasive Activity-based Control of an Implantable Rotary Blood Pump: Comparative Software Simulation Study
    Karantonis, Dean M.
    Lim, Einly
    Mason, David G.
    Salamonsen, Robert F.
    Ayre, Peter J.
    Lovell, Nigel H.
    [J]. ARTIFICIAL ORGANS, 2010, 34 (02) : E34 - E45