THE INITIAL CLINICAL-EXPERIENCE WITH AN IMPLANTABLE CARDIOVERTER DEFIBRILLATOR ANTITACHYCARDIA PACEMAKER

被引:10
|
作者
SINGER, I
AUSTIN, E
NASH, W
GILBO, J
KUPERSMITH, J
机构
[1] UNIV LOUISVILLE,DIV CARDIOTHORAC,LOUISVILLE,KY 40292
[2] TELECTR INC,ENGLEWOOD,CO
来源
关键词
IMPLANTABLE CARDIOVERTER DEFIBRILLATOR; ANTITACHYCARDIA PACING; VENTRICULAR FIBRILLATION; VENTRICULAR TACHYCARDIA;
D O I
10.1111/j.1540-8159.1991.tb02843.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Guardian(R) antitachycardia pacing (ATP) 4210 is a third generation, multi-programmable cardioverter defibrillator undergoing Phase I clinical trials. The tiered response includes ATP, low energy cardioversion or defibrillation, and bradycardia support. Extensive telemetry is available, including an episode log and details of all episode events. Five patients underwent the implantation of Guardian(R) ATP 4210 as part of a Phase I trial at the University of Louisville. Two of the five patients had multiple VT episodes that were reverted successfully using ATP pacing (slow VT) and defibrillation (fast VT) and VF episodes, which resulted in defibrillation therapy over a follow-up period of 6 to 8 months. Four of the five patients required bradycardia support for bradyarrhythmias unassociated with ATP therapy or defibrillation and one patient required bradycardia postdefibrillation therapy. The device design is microprocessor based and requires continuous interrogation of the microprocessor memory and checks of the validity of programmed parameters to continue its operation. When the safety check fails, the device is designed to shut down its antitachycardia and defibrillator functions. This design feature has a potential for leaving the patient unprotected if the device shuts down. Modification of this feature is required to ensure the device's long-term safety.
引用
收藏
页码:1119 / 1128
页数:10
相关论文
共 50 条
  • [21] CLINICAL-EXPERIENCE WITH THE AUTOMATIC IMPLANTABLE DEFIBRILLATOR
    MIROWSKI, M
    REID, PR
    MOWER, MM
    WATKINS, L
    PLATIA, EV
    GRIFFITH, LSC
    VELTRI, EP
    GUARNIERI, T
    JUANTEGUY, JM
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1985, 78 : 39 - 42
  • [22] Clinical predictors of antitachycardia pacing response in implantable cardioverter defibrillator patients
    Harrison, Joshua W.
    Manola, Akrivi
    Kalluri, Lakshmi K.
    Duvall, W. Lane
    Giedrimiene, Dalia
    Kluger, Jeffrey W.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2019, 42 (09): : 1219 - 1225
  • [23] CLINICAL-EXPERIENCE WITH ORTHOCOR-II - A SOPHISTICATED IMPLANTABLE ANTITACHYCARDIA PACEMAKER (WITH HOLTER AND EPS FACILITIES)
    BURRELL, CJ
    SKEHAN, JD
    JOHNSTON, K
    ROTHMAN, MT
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (03): : 652 - 652
  • [24] AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (AICD) AND ANTITACHYCARDIA PACEMAKER (TACHYLOG) - COMBINED USE IN VENTRICULAR TACHYARRHYTHMIAS
    LUDERITZ, B
    GERCKENS, U
    MANZ, M
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1986, 9 (06): : 1356 - 1360
  • [25] Subcutaneous implantable cardioverter-defibrillator: Initial experience
    Galvao, Pedro
    Cavaco, Diogo
    Adragao, Pedro
    Costa, Francisco
    Carmo, Pedro
    Morgado, Francisco
    Bernardo, Ricardo
    Nunes, Manuela
    Abecasis, Miguel
    Neves, Jose
    Mendes, Miguel
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2014, 33 (09) : 511 - 517
  • [26] Runaway pacemaker in an implantable cardioverter defibrillator
    Carpenter, CM
    Galvin, J
    Guy, M
    McGovern, BA
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1998, 9 (09) : 1008 - 1011
  • [27] Pacemaker and implantable cardioverter defibrillator infections
    Camus, C.
    Donal, E.
    Bodi, S.
    Tattevin, P.
    MEDECINE ET MALADIES INFECTIEUSES, 2010, 40 (08): : 429 - 439
  • [28] Initial clinical experience with the first dual-chamber implantable cardioverter defibrillator
    Lavergne, TT
    Ritter, PP
    Nitzsche, RR
    Saoudi, NN
    Kacet, SS
    Ollitrault, JJ
    Daubert, JCJC
    Lacroix, DD
    Poly, HH
    CIRCULATION, 1996, 94 (08) : 3287 - 3287
  • [29] Initial clinical experience with a dual chamber rate responsive implantable cardioverter defibrillator
    Luceri, RM
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (11): : 1986 - 1988
  • [30] CLINICAL-EXPERIENCE IN PATIENTS WITH IMPLANTABLE CARDIOVERTER DEFIBRILLATORS
    TSUJI, H
    SHAHIAN, DM
    VENDITTI, FJ