THE INITIAL CLINICAL-EXPERIENCE WITH AN IMPLANTABLE CARDIOVERTER DEFIBRILLATOR ANTITACHYCARDIA PACEMAKER

被引:10
|
作者
SINGER, I
AUSTIN, E
NASH, W
GILBO, J
KUPERSMITH, J
机构
[1] UNIV LOUISVILLE,DIV CARDIOTHORAC,LOUISVILLE,KY 40292
[2] TELECTR INC,ENGLEWOOD,CO
来源
关键词
IMPLANTABLE CARDIOVERTER DEFIBRILLATOR; ANTITACHYCARDIA PACING; VENTRICULAR FIBRILLATION; VENTRICULAR TACHYCARDIA;
D O I
10.1111/j.1540-8159.1991.tb02843.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Guardian(R) antitachycardia pacing (ATP) 4210 is a third generation, multi-programmable cardioverter defibrillator undergoing Phase I clinical trials. The tiered response includes ATP, low energy cardioversion or defibrillation, and bradycardia support. Extensive telemetry is available, including an episode log and details of all episode events. Five patients underwent the implantation of Guardian(R) ATP 4210 as part of a Phase I trial at the University of Louisville. Two of the five patients had multiple VT episodes that were reverted successfully using ATP pacing (slow VT) and defibrillation (fast VT) and VF episodes, which resulted in defibrillation therapy over a follow-up period of 6 to 8 months. Four of the five patients required bradycardia support for bradyarrhythmias unassociated with ATP therapy or defibrillation and one patient required bradycardia postdefibrillation therapy. The device design is microprocessor based and requires continuous interrogation of the microprocessor memory and checks of the validity of programmed parameters to continue its operation. When the safety check fails, the device is designed to shut down its antitachycardia and defibrillator functions. This design feature has a potential for leaving the patient unprotected if the device shuts down. Modification of this feature is required to ensure the device's long-term safety.
引用
收藏
页码:1119 / 1128
页数:10
相关论文
共 50 条
  • [1] INITIAL CLINICAL-EXPERIENCE WITH THE PACEMAKER-CARDIOVERTER-DEFIBRILLATOR
    YEE, R
    KLEIN, GJ
    GUIRAUDON, GM
    JONES, DL
    SHARMA, AD
    NORRIS, C
    CANADIAN JOURNAL OF CARDIOLOGY, 1990, 6 (04) : 147 - 156
  • [2] CLINICAL-EXPERIENCE WITH THE IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    MIROWSKI, M
    REID, PR
    MOWER, MM
    WATKINS, L
    PLATIA, EV
    GRIFFITH, LSC
    JUANTEGUY, JM
    ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1984, 427 (JUN) : 297 - 306
  • [4] CLINICAL-EXPERIENCE WITH THE IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    WILLIAMS, JM
    ROCK, DT
    PABST, SJ
    GRILL, CR
    DEANTONIO, HJ
    MAHMUD, R
    CHITWOOD, WR
    ANNALS OF THORACIC SURGERY, 1994, 58 (04): : 1297 - 1303
  • [5] CLINICAL-EXPERIENCE WITH ANTITACHYCARDIA PACING AND IMPROVED DETECTION ALGORITHMS IN A NEW IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    WIETHOLT, D
    BLOCK, M
    ISBRUCH, F
    BOCKER, D
    BORGGREFE, M
    SHENASA, M
    BREITHARDT, G
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (04) : 885 - 894
  • [6] AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR - CLINICAL-EXPERIENCE AND COMPLICATIONS
    MASTERSON, M
    WILKOFF, B
    CASTLE, L
    MORANT, V
    GOLDING, L
    SIMMONS, T
    MALONEY, JD
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (02): : 435 - 435
  • [7] CLINICAL-EXPERIENCE WITH THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    MIROWSKI, M
    REID, PR
    MOWER, MM
    WATKINS, L
    GRIFFITH, LSC
    PLATIA, EV
    GUARNIERI, T
    VELTRI, R
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1985, 8 (03): : A58 - A58
  • [8] CLINICAL-EXPERIENCE WITH AN AUTOMATIC ANTITACHYCARDIA IMPLANTABLE PACEMAKER IN THE TREATMENT OF SUPRAVENTRICULAR TACHYCARDIA
    DISERTORI, M
    VERGARA, G
    INAMA, G
    GUARNERIO, M
    FURLANELLO, F
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1985, 8 (03): : A66 - A66
  • [9] 5 YEAR CLINICAL-EXPERIENCE WITH THE AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR
    MERCANDO, AD
    JOHNSTON, D
    FRAME, R
    FISHER, JD
    BRODMAN, R
    FURMAN, S
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (04): : 982 - 982
  • [10] RECENT CLINICAL-EXPERIENCE WITH THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    MIROWSKI, M
    MOWER, MM
    VELTRI, EP
    JUANTEGUY, JM
    REID, PR
    MEDICAL INSTRUMENTATION, 1986, 20 (05): : 285 - 291