PHARMACOKINETICS AND PHARMACODYNAMICS OF ATRACURIUM OBTAINED WITH ARTERIAL AND VENOUS-BLOOD SAMPLES

被引:44
|
作者
DONATI, F
VARIN, F
DUCHARME, J
GILL, SS
THEORET, Y
BEVAN, DR
机构
[1] MCGILL UNIV,MONTREAL H3A 2T5,QUEBEC,CANADA
[2] UNIV MONTREAL,FAC PHARM,MONTREAL H3C 3J7,QUEBEC,CANADA
[3] UNIV MONTREAL,DEPT PHARMACOL,MONTREAL H3C 3J7,QUEBEC,CANADA
关键词
D O I
10.1038/clpt.1991.62
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
To determine the influence of sampling site on atracurium pharmacokinetic-pharmacodynamic relationships, blood was drawn simultaneously from the radial artery and a peripheral vein during a 20-minute period after injection of atracurium, 0.2 mg/kg, in eight patients. Atracurium and laudanosine concentrations were measured by HPLC. Neuromuscular blockade was measured at the adductor pollicis, after stimulation of the ulnar nerve. Venous levels were lower than corresponding arterial values for up to 20 minutes, and this difference was marked for the early samples. Neuromuscular blockade was maximum after 5 to 7 minutes, much later than the peak venous concentration (1 to 3 minutes). Nonparametric analysis yielded (mean +/- SEM) a rate constant, concentration for 50% blockade, and slope of the effect-concentration relationship of 0.092 +/- 0.01 min-1, 379 +/- 27 ng/ml, and 7.3 +/- 1.67, respectively, when based on arterial samples. The values were statistically different (0.135 +/- 0.011 min-1, 235 +/- 42 ng/ml, and 3.41 +/- 0.37, respectively) when venous levels were used (p < 0.05). It is concluded that forearm venous levels do not correspond to adductor pollicis neuromuscular blockade and the kinetics and kinetic-dynamic relationship for atracurium are heavily dependent on sampling site.
引用
收藏
页码:515 / 522
页数:8
相关论文
共 50 条
  • [21] DENBUFYLLINE, PENTOXIFYLLINE AND ZY-16075 DECREASE RAT ARTERIAL AND VENOUS-BLOOD VISCOSITY, BUT NOT HUMAN VENOUS-BLOOD VISCOSITY INVITRO
    BEZENCON, ML
    ROUX, J
    GRANDJEAN, EM
    IMAMURA, T
    CLINICAL HEMORHEOLOGY, 1990, 10 (02): : 215 - 223
  • [22] ARTERIAL AND VENOUS-BLOOD GAS ABNORMALITIES DURING CARDIOPULMONARY RESUSCITATION
    WEAVER, WD
    SWENSON, RD
    EMORY, M
    NISKENEN, R
    CLINICAL RESEARCH, 1985, 33 (01): : A19 - A19
  • [23] EFFECT OF VASOACTIVE AGENTS ON THE DENSITY OF ARTERIAL AND VENOUS-BLOOD AND PLASMA
    HINGHOFERSZALKAY, H
    KENNER, T
    LEOPOLD, H
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1979, 379 : R10 - R10
  • [24] ARTERIAL AND VENOUS-BLOOD FLOW - NONINVASIVE QUANTITATION WITH MR IMAGING
    PELC, LR
    PELC, NJ
    RAYHILL, SC
    CASTRO, LJ
    GLOVER, GH
    HERFKENS, RJ
    MILLER, DC
    JEFFREY, RB
    RADIOLOGY, 1992, 185 (03) : 809 - 812
  • [25] A MODEL OF PHASIC ARTERIAL AND VENOUS-BLOOD FLOW IN THE CORONARY CIRCULATION
    SABBAH, HN
    HAMID, MS
    RANKIN, GW
    STEIN, PD
    COMPUTERS & STRUCTURES, 1993, 46 (04) : 741 - 749
  • [26] ARTERIAL AND VENOUS-BLOOD SAMPLING IN PHARMACOKINETIC STUDIES - AZOSEMIDE IN RABBITS
    LEE, SH
    SHIN, WG
    LEE, MG
    KIM, ND
    BIOPHARMACEUTICS & DRUG DISPOSITION, 1994, 15 (04) : 305 - 316
  • [27] ARTERIAL AND VENOUS-BLOOD SAMPLINGS IN PHARMACOKINETIC STUDIES - VANCOMYCIN IN RABBITS
    SHIN, WG
    LEE, MG
    LEE, MH
    JOURNAL OF CLINICAL PHARMACY AND THERAPEUTICS, 1993, 18 (02) : 115 - 122
  • [28] OXYGEN PARAMETERS OF ARTERIAL AND MIXED VENOUS-BLOOD, - NEW AND OLD
    SIGGAARDANDERSEN, O
    GOTHGEN, IH
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1995, 39 : 41 - 46
  • [29] ARTERIAL AND MIXED VENOUS-BLOOD GAS TENSIONS IN EXERCISING DUCKS
    KILEY, JP
    KUHLMANN, WD
    FEDDE, MR
    POULTRY SCIENCE, 1980, 59 (04) : 914 - 917
  • [30] DIFFERENCES IN LIPID AND LIPOPROTEIN CONCENTRATIONS OF CAPILLARY AND VENOUS-BLOOD SAMPLES
    KUPKE, IR
    ZEUGNER, S
    GOTTSCHALK, A
    KATHER, B
    CLINICA CHIMICA ACTA, 1979, 97 (2-3) : 279 - 283