DEVELOPMENT AND USE OF AN IN-VITRO SYSTEM TO EVALUATE INHALER DEVICES

被引:15
|
作者
NIVEN, RW [1 ]
LOTT, FD [1 ]
IP, AY [1 ]
SOMARATNE, KD [1 ]
KEARNEY, M [1 ]
机构
[1] TECHMEDICA,CAMARILLO,CA 93012
关键词
AEROSOL; ARTIFICIAL THROAT; DEPOSITION; DRY POWDER INHALER; LUNG; METERED DOSE INHALER;
D O I
10.1016/0378-5173(94)90078-7
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
An in vitro system was developed to better emulate particle deposition in the respiratory tract. Inhalers were connected to a glass throat (BP 1988 Appendix XVII C) or to a silicone throat that exactly duplicated the surface geometry of the oral and pharyngeal cavity. This throat was created from a direct impression of the mouth and CAT scans of a patient's head and neck and could be separated into three parts. This allowed deposition patterns to be observed. Adapters were fabricated so that the outlet of either throat could be connected to a collection filter unit or any one of several sizing instruments. A mass flow meter enabled airflow to be monitored. Airflow was produced from a vacuum pump or by human inhalation. A Rotahaler was tested using capsules containing 20 mg of spray dried mannitol:sorbitol:carboxyfluorescein (CF) 10:1:0.01 of 3.4 mu m MMAD. The vacuum pump was set at 30, 60 or 120 1/min air flow for 4 s. The surface of the glass or silicone throat was left 'dry' or was coated with a polyethylene glycol mixture to better represent the 'wet' surface of the oral cavity. Powder in the device, filter unit and throat(s) was quantified by assay of the CF using spectrofluorimetry. The recovery of the weighed dose was 98.6 +/- 8.9% (n = 83). The dose emerging from the inhaler was dependent on the flow rate (Anova, p < 0.01) and was 1.0 +/- 0.2 mg (30 1/min, n = 25), 5.1 +/- 0.5 mg (60 1/min, n = 30) and 6.2 +/- 0.6 mg (120 1/min, n = 28). However, the percentage of this dispensed dose recovered from the filter unit (lung) was independent of the flow rate and only varied with the type and condition of the throat used (Anova, p < 0.05). The mass deposition in the throats was ranked: glass-dry < silicone-dry < glass-wet < silicone-wet. The results indicate that the use of a wet artificial throat, modeled on human anatomy, will provide a more conservative estimate of lung deposition compared to a glass throat when used with a dry powder inhaler.
引用
收藏
页码:81 / 87
页数:7
相关论文
共 50 条
  • [21] The use of computational approaches in inhaler development
    Wong, William
    Fletcher, David F.
    Traini, Daniela
    Chan, Hak-Kim
    Young, Paul M.
    ADVANCED DRUG DELIVERY REVIEWS, 2012, 64 (04) : 312 - 322
  • [22] Inhalation through two mini-spacer-like inhaler technique training devices: An in-vitro aerosol delivery comparative study
    Ammari, Wesam
    Oda, Dunya
    EUROPEAN RESPIRATORY JOURNAL, 2024, 64
  • [23] DEVELOPMENT IN IN-VITRO TOXICOLOGY
    FRY, JR
    COMPARATIVE HAEMATOLOGY INTERNATIONAL, 1993, 3 (01): : 4 - 7
  • [24] Development of Sustained Release Oseltamivir Phosphate Dry Powder Inhaler: In-Vitro Characterization and In-Vivo Toxicological Studies
    Sahastrabudhe, Harshal
    Kenjale, Prathmesh
    Pokharkar, Varsha
    CURRENT DRUG DELIVERY, 2020, 17 (08) : 703 - 710
  • [25] Development and Use of Heuristics to Evaluate Neonatal Medical Devices for Use in Low-Resource Settings
    Johnston, Jake
    Asma, Elizabeth
    Acemyan, Claudia Ziegler
    Oden, Maria
    Richards-Kortum, Rebecca
    Kortum, Philip
    JOURNAL OF USABILITY STUDIES, 2021, 17 (01) : 12 - 20
  • [26] What in-vitro method should surgeons use to evaluate the clinical behavior of arterial bypass conduits
    Montgomery, WD
    Vitolla, G
    Ali, A
    Pagni, S
    Ballen, JL
    Santamore, WP
    Calafiore, AM
    Spence, PA
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1997, 12 (03) : 436 - 442
  • [27] DEVELOPMENT OF AN IN-VITRO CULTURE SYSTEM FOR THE STUDY OF OSTEOCLAST ACTIVITY AND FUNCTION
    GILLES, JA
    CARNES, DL
    WINDELER, AS
    JOURNAL OF ENDODONTICS, 1994, 20 (07) : 327 - 331
  • [28] A unique biological in-vivo model to evaluate follicular development during in-vitro maturation treatment
    Elizur, S. E.
    Son, W. Y.
    Clarke, H.
    Morris, D.
    Gidoni, Y.
    Demirtas, E.
    Tan, S. L.
    REPRODUCTIVE BIOMEDICINE ONLINE, 2011, 22 (03) : 257 - 262
  • [29] KNOWLEDGE OF HEALTH CARE PROFESSIONALS ON THE USE OF DIFFERENT INHALER DEVICES
    Tarsin, W.
    Alshamli, I.
    Soussi, M.
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2013, 26 (02) : A52 - A53
  • [30] Regular and correct use of inhaler devices and relation to asthma control
    Capanoglu, M.
    Misirlioglu, Dibek E.
    Toyran, M.
    Civelek, E.
    Kocabas, C. N.
    ALLERGY, 2014, 69 : 440 - 440